Contamination of Handpieces during Pulpotomy Therapy on Primary Teeth

被引:0
作者
Chin, Judith R. [1 ]
Westerman, Amy E. [1 ]
Palenik, Charles J.
Eckert, Steven George J. [2 ]
机构
[1] Indiana Univ, Sch Dent, Div Pediat Dent, Indianapolis, IN 46204 USA
[2] Indiana Univ, Sch Med, Div Biostat, Indianapolis, IN USA
关键词
INFECTION CONTROL; HANDPIECE; PULPOTOMY; EQUIPMENT CONTAMINATION; STERILIZATION; ROTARY DENTAL INSTRUMENTS; LOW-SPEED HANDPIECES; INFECTION; ANGLES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this in vivo study was to determine the potential for internal bacterial contamination of low-speed handpiece/contra-angle systems. Methods: Clinical contamination was measured for 24 pulpotomies on primary first or second molar teeth from 20 subjects. The investigators used microbiologic analysis to determine the extent of bacterial contamination from the patient's saliva using enriched trypticase soy agar (ETSA) plates. Analysis for the presence of blood also occurred. Results: Microbial analysis indicated aerobic and anaerobic bacterial contamination at all 3 culturing sites from all 24 handpieces (100% contamination, 95% confidence intervals [CI]=86%-100%). Aerobic and anaerobic bacteria levels (CFU/mL) were not significantly different (P=.43 overall, P.>.25 for each of the 3 evaluated sites). The sites also did not have significantly different CFU/mL levels (P=.13 overall, P=.63 for aerobic, P=.14 for anaerobic). The analysis showed no blood contamination at any of the 3 culturing sites for any of the 24 handpieces (0% contamination, 95% CI=0%-14%). Conclusions: The in vivo data suggest that low-speed handpiece/contra-angle systems can become bacterially contaminated during the performance of pulpotomies and, unless properly sterilized between patients, there is the potential for pathogenic micro-organisms to enter, adhere, and then emit during use on subsequent patients. (Pediatr Dent 2009;31:71-5) Received November 3, 2007 vertical bar Lost Revision April 18, 2008 vertical bar Revision Accepted May 3, 2008
引用
收藏
页码:71 / 75
页数:5
相关论文
共 22 条
[1]   Internal contamination of air-driven low-speed handpieces and attached prophy angles [J].
Chin, Judith R. ;
Miller, Chris H. ;
Palenik, Charles John .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2006, 137 (09) :1275-1280
[2]   STATE-OF-THE-ART INFECTION CONTROL IN DENTISTRY [J].
COTTONE, JA ;
MOLINARI, JA .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1991, 122 (09) :33-41
[3]  
CRAWFORD JJ, 1998, J AM DENT ASSOC, V117, P653
[4]  
Dreyer A G, 2001, SADJ, V56, P510
[5]   ASSESSING VIRAL RETENTION - AND ELIMINATION IN ROTARY DENTAL INSTRUMENTS [J].
EPSTEIN, JB ;
REA, G ;
SIBAU, L ;
SHERLOCK, CH ;
LE, ND .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1995, 126 (01) :87-92
[6]   ROTARY DENTAL INSTRUMENTS AND THE POTENTIAL RISK OF TRANSMISSION OF INFECTION - HERPES-SIMPLEX VIRUS [J].
EPSTEIN, JB ;
REA, G ;
SIBAU, L ;
SHERLOCK, CH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1993, 124 (12) :55-59
[7]   The in vivo contamination air-driven low-speed handpieces with prophylaxis angles [J].
Herd, Sarah ;
Chin, Judith ;
Palenik, Charles John ;
Ofner, Susan .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2007, 138 (10) :1360-1365
[8]  
KOHN WG, 2003, MMWR RECOMM REP, V19, P1
[9]  
KUEHNE JS, 1992, 9203 NDRIPR
[10]   Performance of high-speed dental handpieces - Subjected to simulated clinical use and sterilization [J].
Leonard, DL ;
Charlton, DG .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1999, 130 (09) :1301-1311