Experimental determination of electron source parameters for accurate Monte Carlo calculation of large field electron therapy

被引:20
作者
Huang, VW [1 ]
Seuntjens, J [1 ]
Devic, S [1 ]
Verhaegen, F [1 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
关键词
D O I
10.1088/0031-9155/50/5/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Extensive work has been performed to validate Monte Carlo models for both photon and electron beams under standard conditions. However, for large field electron beam therapy, Monte Carlo simulations have not been able to provide good agreement when compared to the measured dose distributions. Since the accuracy of the calculation relies heavily on the geometry parameters of the linear accelerator and the characteristics of the incident electron beam, it is crucial to have a complete comprehension of these independent factors. In this work, the electron focal spot size for a CL21EX linac with various energies (6, 9, 12 and 16 MeV) was measured with a slit camera composed of alternating lead and paper sheets. For all the energies investigated, the electron focal spot is found to be elliptical and has a full width at half maximum (FWHM) ranging from 1.69 mm to 2.24 mm. A shift with respect to the crosshair was associated with each measured focal spot. In addition, we present an improved result for the large field in-air profile by utilizing a proposed divergent beam model in conjunction with the experimental focal spot dimension. This model can potentially provide a solution to the Monte Carlo validation of large field electron beam therapy.
引用
收藏
页码:779 / 786
页数:8
相关论文
共 19 条
[1]   Using Monte Carlo methods to commission electron beams: A feasibility study [J].
Antolak, JA ;
Bieda, MR ;
Hogstrom, KR .
MEDICAL PHYSICS, 2002, 29 (05) :771-786
[2]   R(50) as a beam quality specifier for selecting stopping-power ratios and reference depths for electron dosimetry [J].
Burns, DT ;
Ding, GX ;
Rogers, DWO .
MEDICAL PHYSICS, 1996, 23 (03) :383-388
[3]   Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator [J].
Ding, GX .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) :1025-1046
[4]  
*ICRU, 1976, 24 INT COMM RAD UN M
[5]   X-RAY SOURCES OF MEDICAL LINEAR ACCELERATORS - FOCAL AND EXTRA-FOCAL RADIATION [J].
JAFFRAY, DA ;
BATTISTA, JJ ;
FENSTER, A ;
MUNRO, P .
MEDICAL PHYSICS, 1993, 20 (05) :1417-1427
[6]   Electron beam modeling and commissioning for Monte Carlo treatment planning [J].
Jiang, SB ;
Kapur, A ;
Ma, CM .
MEDICAL PHYSICS, 2000, 27 (01) :180-191
[7]   Monte Carlo calculations of electron beam output factors for a medical linear accelerator [J].
Kapur, A ;
Ma, CM ;
Mok, EC ;
Findley, DO ;
Boyer, AL .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12) :3479-3494
[8]   Monte Carlo simulation of a clinical linear accelerator [J].
Lin, SY ;
Chu, TC ;
Lin, JP .
APPLIED RADIATION AND ISOTOPES, 2001, 55 (06) :759-765
[9]   MEASUREMENT OF THE SOURCE SIZE OF A 6-MV AND 18-MV RADIOTHERAPY LINAC [J].
LOEWENTHAL, E ;
LOEWINGER, E ;
BARAVRAHAM, E ;
BARNEA, G .
MEDICAL PHYSICS, 1992, 19 (03) :687-690
[10]   EVALUATION OF A BEAM-SPOT CAMERA FOR MEGAVOLTAGE X-RAYS [J].
LUTZ, WR ;
MALEKI, N ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1988, 15 (04) :614-617