Scaling Trace Organic Contaminant Adsorption Capacity by Granular Activated Carbon

被引:77
作者
Corwin, Christopher J. [1 ]
Summers, R. Scott [1 ]
机构
[1] Univ Colorado, Dept Civil Environm & Architectural Engn, Boulder, CO 80309 USA
关键词
FIXED-BED; GAC ADSORPTION; NATURAL-WATERS; COLUMN TESTS; ADSORBERS; MODEL; THERMODYNAMICS; ATRAZINE; DESIGN; OXYGEN;
D O I
10.1021/es9037462
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The role of particle size on the reduction of granular activated carbon (GAC) adsorption capacity for trace organic contaminants by dissolved organic matter (DOM) is examined and applied to performance scale-up. The adsorption capacity reduction, termed fouling, must be scalable in order to use bench scale tests, such as the rapid small-scale column test (RSSCT)to predict full-scale breakthrough. Equilibrium adsorption capacity tests with GAC preloaded with DOM and RSSCT breakthrough curves at three different GAC particle sizes indicate that GAC adsorption capacity is dependent on GAC particle size when DOM is present Thus, the RSSCT cannot be expected to match full-scale results regardless of which RSSCT design approach is used (constant or proportional diffusivity), unless a scaling factor is applied to the results. Proportional diffusivity RSSCT breakthrough curves demonstrate that surface concentration of DOM is not a good measure of fouling. It is hypothesized that pore blockage is the mechanism responsible for the dependence on particle size. As GAC particle size increases, the microporous surface area behind a constricted pore also increases. The result is lower adsorption capacity per mass of adsorbent in the larger GAC particles. A scaling methodology for equilibrium and breakthrough data is presented that accounts for the dependence of NOM preloading effects on GAC particle diameter.
引用
收藏
页码:5403 / 5408
页数:6
相关论文
共 25 条
[1]   EFFECT OF INFLUENT OXYGEN CONCENTRATION ON THE GAC ADSORPTION OF VOCS IN THE PRESENCE OF BOM [J].
CERMINARA, PJ ;
SORIAL, GA ;
PAPADIMAS, SP ;
SUIDAN, MT ;
MOTELEB, MA ;
SPETH, TF .
WATER RESEARCH, 1995, 29 (02) :409-419
[2]  
CLESCERI LS, 1998, STAND METHODS EXAM W
[3]  
Crittenden J.C., 1989, 90549 AM WAT WORKS A
[4]  
CRITTENDEN JC, 1986, J WATER POLLUT CON F, V58, P312
[5]  
CRITTENDEN JC, 1985, ENVIRON SCI TECHNOL, V19, P1037, DOI 10.1021/es00141a002
[6]  
CRITTENDEN JC, 1991, J AM WATER WORKS ASS, V83, P77
[7]   DESIGN OF RAPID FIXED-BED ADSORPTION TESTS FOR NONCONSTANT DIFFUSIVITIES [J].
CRITTENDEN, JC ;
BERRIGAN, JK ;
HAND, DW ;
LYKINS, B .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1987, 113 (02) :243-259
[8]  
Frick B., 1982, Aktuelle Probleme der Wasserchemie und der Wasseraufbereitung
[9]   Modeling equilibrium adsorption of 2-methylisoborneol and geosmin in natural waters [J].
Graham, MR ;
Summers, RS ;
Simpson, MR ;
MacLeod, BW .
WATER RESEARCH, 2000, 34 (08) :2291-2300
[10]  
HINELINE D, 1987, P AM WAT WORKS ASS A