Diagnostic Value of Ganglion Cell-Inner Plexiform Layer Thickness in Glaucoma With Superior or Inferior Visual Hemifield Defects

被引:11
作者
Kim, Ho Soong [1 ]
Yang, Heon [1 ]
Lee, Tae Heon [1 ]
Lee, Kyung Heon [1 ]
机构
[1] Sungmo Eye Hosp, 409-1 Haeundae Ro, Busan 612823, South Korea
关键词
hemifield defect glaucoma; ganglion cell-inner plexiform layer; optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; NERVE-FIBER LAYER; PREPERIMETRIC GLAUCOMA; ACCURACY; ABILITY; DAMAGE;
D O I
10.1097/IJG.0000000000000285
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the diagnostic value of the ganglion cell-inner plexiform layer (GCIPL) thickness in glaucomatous eyes with superior or inferior visual hemifield defects. Patients and Methods: Eighty-five patients with glaucoma (42 isolated superior hemifield defects and 43 isolated inferior hemifield defects) and 46 normal subjects were enrolled. All patients underwent Cirrus high-definition optical coherence tomography and standard automated perimetry. The area under the receiver operating characteristic curve (AUC) was calculated to determine the diagnostic ability of the GCIPL and peripapillary retinal nerve fiber layer (pRNFL). Results: In the superior hemifield defect glaucoma group, the best parameters for discriminating normal eyes from glaucomatous eyes were the inferotemporal GCIPL thickness (0.942), inferior quadrant RNFL thickness (0.974), and 7 o'clock sector RNFL thickness (0.999). For diagnosing inferior hemifield defect glaucoma, the AUCs of all GCIPL parameters (0.331 to 0.702) were significantly lower than that of the superior quadrant RNFL thickness (0.866, P < 0.05). Conclusions: The diagnostic ability of GCIPL parameters was similar to that of the pRNFL parameters in superior hemifield defect glaucoma. However, the diagnostic performance of the GCIPL parameters was significantly inferior to those of the pRNFL parameters in eyes with inferior hemifield defect glaucoma.
引用
收藏
页码:472 / 476
页数:5
相关论文
共 15 条
  • [1] Comparative Assessment for the Ability of Cirrus, RTVue, and 3D-OCT to Diagnose Glaucoma
    Akashi, Azusa
    Kanamori, Akiyasu
    Nakamura, Makoto
    Fujihara, Masashi
    Yamada, Yuko
    Negi, Akira
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4478 - 4484
  • [2] Ganglion Cell-Inner Plexiform Layer Thickness of High Definition Optical Coherence Tomography in Perimetric and Preperimetric Glaucoma
    Begum, Viquar U.
    Addepalli, Uday K.
    Yadav, Ravi K.
    Shankar, Kalmuri
    Senthil, Sirisha
    Garudadri, Chandra S.
    Rao, Harsha L.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (08) : 4768 - 4775
  • [3] Glaucomatous damage of the macula
    Hood, Donald C.
    Raza, Ali S.
    de Moraes, Carlos Gustavo V.
    Liebmann, Jeffrey M.
    Ritch, Robert
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2013, 32 : 1 - 21
  • [4] The Nature of Macular Damage in Glaucoma as Revealed by Averaging Optical Coherence Tomography Data
    Hood, Donald C.
    Raza, Ali S.
    de Moraes, Carlos Gustavo V.
    Johnson, Chris A.
    Liebmann, Jeffrey M.
    Ritch, Robert
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2012, 1 (01):
  • [5] Macular Ganglion Cell Imaging Study: Glaucoma Diagnostic Accuracy of Spectral-Domain Optical Coherence Tomography
    Jeoung, Jin Wook
    Choi, Yun Jeong
    Park, Ki Ho
    Kim, Dong Myung
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4422 - 4429
  • [6] Severity-dependent association between ganglion cell inner plexiform layer thickness and macular mean sensitivity in open-angle glaucoma
    Kim, Ko Eun
    Park, Ki Ho
    Jeoung, Jin Wook
    Kim, Seok Hwan
    Kim, Dong Myung
    [J]. ACTA OPHTHALMOLOGICA, 2014, 92 (08) : e650 - e656
  • [7] Comparison of macular GCIPL and peripapillary RNFL deviation maps for detection of glaucomatous eye with localized RNFL defect
    Kim, Mi Jeung
    Park, Ki Ho
    Yoo, Beong Wook
    Jeoung, Jin Wook
    Kim, Hee Chan
    Kim, Dong Myung
    [J]. ACTA OPHTHALMOLOGICA, 2015, 93 (01) : E22 - E28
  • [8] Topographic Profiles of Retinal Nerve Fiber Layer Defects Affect the Diagnostic Performance of Macular Scans in Preperimetric Glaucoma
    Kim, Mi Jeung
    Jeoung, Jin Wook
    Park, Ki Ho
    Choi, Yun Jeong
    Kim, Dong Myung
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (04) : 2079 - 2087
  • [9] RELIABILITY OF OPTIC DISK TOPOGRAPHIC MEASUREMENTS RECORDED WITH VIDEO-OPHTHALMOGRAPH
    MIKELBERG, FS
    DOUGLAS, GR
    SCHULZER, M
    CORNSWEET, TN
    WIJSMAN, K
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 98 (01) : 98 - 102
  • [10] Glaucoma Diagnostic Accuracy of Ganglion Cell-Inner Plexiform Layer Thickness: Comparison with Nerve Fiber Layer and Optic Nerve Head
    Mwanza, Jean-Claude
    Durbin, Mary K.
    Budenz, Donald L.
    Sayyad, Fouad E.
    Chang, Robert T.
    Neelakantan, Arvind
    Godfrey, David G.
    Carter, Randy
    Crandall, Alan S.
    [J]. OPHTHALMOLOGY, 2012, 119 (06) : 1151 - 1158