Nickel hexacyanoferrate modified screen-printed carbon electrode for sensitive detection of ascorbic acid and hydrogen peroxide

被引:26
作者
Lin, J
Zhou, DM
Hocevar, SB
McAdams, ET
Ogorevc, B
Zhang, XJ
机构
[1] Natl Inst Chem, Analyt Chem Lab, Ljubljana 1001, Slovenia
[2] Univ Ulster, No Ireland Bioengn Ctr, Jordanstown BT37 0QB, North Ireland
来源
FRONTIERS IN BIOSCIENCE-LANDMARK | 2005年 / 10卷
关键词
screen-printed electrode; modified electrode; cyclic voltammetry; nickel hexacyanoferrate; ascorbic acid; hydrogen peroxide;
D O I
10.2741/1544
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Electrochemically modified screen-printed carbon electrode (SPCE) has been prepared by electrodepositing nickel hexacyanoferrate(III) (NiHCF) onto the electrode surface using cyclic voltammetry ( CV). The performance of NiHCF-SPCE sensor was characterized and optimized by controlling several operational parameters. The NiHCF film has been proven to remain stable after CV scanning from 0 to + 1.0 V vs. Ag/AgCl in the pH range of 3 to 10 and is re-useable. The most favourable supporting electrolyte solution exhibiting the optimum electroanalytical performance of the NiHCF-SPCE sensor was found to be 0.2 mol/L sodium nitrate. The electrochemical response toward ascorbic acid ( AA) and H2O2 in 0.2 mol/L sodium nitrate solution was studied by using CV and the results showed that both analytes were electrocatalytically oxidized at approximately + 0.4 V, while H2O2 also revealed a reduction signal at - 0.8 V vs. Ag/AgCl. The NiHCF-SPCE sensor exhibited highly linear response for AA and H2O2 in the examined concentration range from 5.0x10(-5) to 1.5x10(-3) mol/ L and from 2.0x10(-5) to 1.0x10(-3) mol/L ( at + 0.4 V), with the correlation coefficients of 0.999 and 0.998, respectively. The reproducibility of the NiHCF-SPCE sensor was followed for the determination of AA by using four individual electrodes, and the relative standard deviation of CV peak currents varied between 0.9 % and 2.2 %. The proposed NiHCF-SPCE has been shown to be a very attractive electrochemical sensor for AA and H2O2, also in a view of inexpensive mass production of disposable single-use sensors. The NiHCF-SPCE sensor was tested by measuring AA in multivitamin tablets, with recoveries obtained between 94.4 % and 108.2 % ( n= 5).
引用
收藏
页码:483 / 491
页数:9
相关论文
共 35 条
[1]   Electrocatalytic activity of a cobalt hexacyanoferrate modified glassy carbon electrode toward ascorbic acid oxidation [J].
Cai, CX ;
Xue, KH ;
Xu, SM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 486 (02) :111-118
[2]   Metal-hexacyanoferrate films: A tool in analytical chemistry. [J].
de Mattos, IL ;
Gorton, L .
QUIMICA NOVA, 2001, 24 (02) :200-205
[3]   Self-gelatinizable copolymer immobilized glucose biosensor based on Prussian Blue modified graphite electrode [J].
Deng, Q ;
Li, B ;
Dong, SJ .
ANALYST, 1998, 123 (10) :1995-1999
[4]   An immunomagnetic electrochemical sensor based an a perfluorosulfonate-coated screen-printed electrode for the determination of 2,4-dichlorophenoxyacetic acid [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2571-2577
[5]   Screen printing of nucleic acid detecting carbon electrodes [J].
Dequaire, M ;
Heller, A .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4370-4377
[6]   PROTOTYPE, SOLID-PHASE, GLUCOSE BIOSENSOR [J].
GILMARTIN, MAT ;
HART, JP ;
PATTON, DT .
ANALYST, 1995, 120 (07) :1973-1981
[7]   NOVEL, REAGENTLESS, AMPEROMETRIC BIOSENSOR FOR URIC-ACID BASED ON A CHEMICALLY-MODIFIED SCREEN-PRINTED CARBON ELECTRODE COATED WITH CELLULOSE-ACETATE AND URICASE [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1994, 119 (05) :833-840
[8]   Nickel hexacyanoferrate membrane as a coated wire cation-selective electrode [J].
Giorgetti, M ;
Scavetta, E ;
Berrettoni, M ;
Tonelli, D .
ANALYST, 2001, 126 (12) :2168-2171
[9]   SCREEN-PRINTED ENZYME ELECTRODE FOR THE DETERMINATION OF LACTOSE [J].
JAGER, A ;
BILITEWSKI, U .
ANALYST, 1994, 119 (06) :1251-1255
[10]   PRINTED ELECTROCHEMICAL SENSOR FOR ASCORBIC-ACID DETERMINATION [J].
KULYS, J ;
DCOSTA, EJ .
ANALYTICA CHIMICA ACTA, 1991, 243 (02) :173-178