Relative exchangeable copper: A new highly sensitive and highly specific biomarker for Wilson's disease diagnosis

被引:103
作者
El Balkhi, Souleiman [1 ,4 ]
Trocello, Jean-Marc [2 ,4 ]
Poupon, Joel [1 ]
Chappuis, Philippe [3 ]
Massicot, France [5 ]
Girardot-Tinant, Nadege [4 ]
Woimant, France [2 ,4 ]
机构
[1] Hop Lariboisiere, AP HP, Lab Toxicol Biol, F-75475 Paris 10, France
[2] Hop Lariboisiere, AP HP, Serv Neurol, F-75475 Paris 10, France
[3] Hop Lariboisiere, AP HP, Serv Biochim & Biol Mol, F-75475 Paris 10, France
[4] Hop Lariboisiere, AP HP, Ctr Reference Maladie Wilson, F-75475 Paris 10, France
[5] Univ Paris 05, Fac Pharm, EA 4463, Lab Chim Toxicol Anal & Celullaire, F-75006 Paris, France
关键词
Exchangeable copper; Relative exchangeable copper (REC); Labile copper; ROC analysis; Wilson disease; Diagnosis; CERULOPLASMIN-BOUND COPPER; SERUM; GENE; METABOLISM; MUTATIONS; STABILITY; CHILDREN; ATPASE;
D O I
10.1016/j.cca.2011.08.019
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Wilson disease (WD) is an autosomal recessive inherited disorder of copper metabolism. Failure to diagnose WD can be dramatic leading to irreversible damages. The molecular genetic analysis of ATP7B gene is the reference test for diagnosis but the number of reported mutations of the ATP7B gene is on the rise. The analysis is cumbersome and requires tedious work. Other clinical and biological tests are proposed but it is often difficult to interpret some patients' results. A rapid and reliable biological test for WD diagnosis is still needed. Analytical reliability of Exchangeable copper (CuEXC) determination procedure is examined by studying the repeatability, the short term stability and stability in frozen serum. Relative exchangeable copper (REC=CuEXC/total copper%) is proposed and evaluated as a new diagnostic test and compared to classic tests used for WD diagnosis. Sixteen new Wilson disease patients were diagnosed in our institution between January 2009 and May 2011. The different biological tests used for WD diagnosis yielded lower sensitivity and specificity compared to our new biomarker, the REC. We show that REC is an excellent discriminatory tool for the diagnosis of WD offering 100% sensitivity and 100% specificity. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2254 / 2260
页数:7
相关论文
共 37 条
[1]  
[Anonymous], WD MUTATION DATABASE
[2]   Cellular copper distribution: a mechanistic systems biology approach [J].
Banci, Lucia ;
Bertini, Ivano ;
Cantini, Francesca ;
Ciofi-Baffoni, Simone .
CELLULAR AND MOLECULAR LIFE SCIENCES, 2010, 67 (15) :2563-2589
[3]   Analytical variables affecting exchangeable copper determination in blood plasma [J].
Buckley, Wayne T. ;
Vanderpool, Richard A. .
BIOMETALS, 2008, 21 (06) :601-612
[4]   THE WILSON DISEASE GENE IS A PUTATIVE COPPER TRANSPORTING P-TYPE ATPASE SIMILAR TO THE MENKES GENE [J].
BULL, PC ;
THOMAS, GR ;
ROMMENS, JM ;
FORBES, JR ;
COX, DW .
NATURE GENETICS, 1993, 5 (04) :327-337
[5]   Systems biology approach to Wilson's disease [J].
Burkhead, Jason L. ;
Gray, Lawrence W. ;
Lutsenko, Svetlana .
BIOMETALS, 2011, 24 (03) :455-466
[6]  
Cox D W, 1996, Prog Liver Dis, V14, P245
[7]   Wilson Disease: Novel Mutations in the ATP7B Gene and Clinical Correlation in Brazilian Patients [J].
Deguti, Marta M. ;
Genschel, Janine ;
Cancado, Eduardo L. R. ;
Barbosa, Egberto R. ;
Bochow, Bettina ;
Mucenic, Marcos ;
Porta, Gilda ;
Lochs, Herbert ;
Carrilho, Flair J. ;
Schmidt, Hartmut H. -J. .
HUMAN MUTATION, 2004, 23 (04) :398-+
[8]   Wilson's disease in children: 37-year experience and revised king's score for liver transplantation [J].
Dhawan, A ;
Taylor, RM ;
Cheeseman, P ;
De Silva, P ;
Katsiyiannakis, L ;
Mieli-Vergani, G .
LIVER TRANSPLANTATION, 2005, 11 (04) :441-448
[9]   Human Plasma Copper Proteins Speciation by Size Exclusion Chromatography Coupled to Inductively Coupled Plasma Mass Spectrometry. Solutions for Columns Calibration by Sulfur Detection [J].
El Balkhi, Souleiman ;
Poupon, Joel ;
Trocello, Jean-Marc ;
Massicot, France ;
Woimant, France ;
Laprevote, Olivier .
ANALYTICAL CHEMISTRY, 2010, 82 (16) :6904-6910
[10]   Determination of ultrafiltrable and exchangeable copper in plasma: stability and reference values in healthy subjects [J].
El Balkhi, Souleiman ;
Poupon, Joel ;
Trocello, Jean-Marc ;
Leyendecker, Angelique ;
Massicot, France ;
Galliot-Guilley, Martine ;
Woimant, France .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (05) :1477-1484