CAD/CAM implant surgical guides: maximum errors in implant positioning attributable to the properties of the metal sleeve/osteotomy drill combination

被引:14
作者
Apostolakis, Dimitrios [1 ]
Kourakis, Georgios [1 ]
机构
[1] Plateia 1866,39, Iraklion 73100, Greece
关键词
CAD; CAM; Implant guide; 3d printing; Osteotomy; Stereolithography; IN-VITRO; ACCURACY; SURGERY; TOLERANCE; PLACEMENT; DENTISTRY; TEMPLATE;
D O I
10.1186/s40729-018-0146-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe purpose of this study is to provide the relevant equations and the reference tables needed for calculating the maximum errors in implant positioning attributed to the properties of the mechanical parts of any CAD/CAM implant surgical guide, especially the in-office manufactured ones.MethodsAn algorithm was developed and implemented in C programming language in order to accurately calculate the maximum error at the apex, error at the neck, vertical error at the apex and deviation of implant axis, between the planned and the actual implant position. The calculations were based on the parameters of total length (= implant length + offset), offset (distance from neck of implant to the lip of the metal sleeve), clearance (space between the bur and the sleeve), sleeve length. The variability of the parameters was constrained: (1) implant length, 8-18mm; (2) sleeve length, 4-7mm; (3) clearance, 50-410m; and (4) offset values, 6-17mm. Multiple regression analysis was conducted to quantify the relationship between the error at the apex and the error at the neck and various predictors.ResultsThe equations used for the bespoke estimation of the errors in implant positioning along with three reference tables of the various errors tabulated are presented. The maximum error at the apex of the implant was computed 2.8mm, the maximum deviation of the implant axis 5.9 degrees and the maximum error at the neck (entrance) of the implant was estimated 1.5mm. The vertical error between the planned and actual implant position can be considered negligible (<0.1mm).ConclusionsThe results of this study compute part of the expected differences in final clinical implant position when any CAD/CAM surgical guide is used. Given that the implantologist, with the capability of an in-office digital designed and 3d printed surgical guide, can readily decide upon the dimensions of the metal sleeve, the clearance between the osteotomy bur and the sleeve, and the design of the guide in relation to the distance of the lip of the sleeve to the implant neck (offset), in order to minimise the inevitable errors.
引用
收藏
页数:9
相关论文
共 23 条
[1]   The intrinsic error of a stereolithographic surgical template in implant guided surgery [J].
Cassetta, M. ;
Di Mambro, A. ;
Giansanti, M. ;
Stefanelli, L. V. ;
Cavallini, C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 42 (02) :264-275
[2]   The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study [J].
Cassetta, Michele ;
Di Mambro, Alfonso ;
Di Giorgio, Gianni ;
Stefanelli, Luigi V. ;
Barbato, Ersilia .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (03) :580-588
[3]   Current state of the art of computer-guided implant surgery [J].
D'haese, Jan ;
Ackhurst, Johan ;
Wismeijer, Daniel ;
De Bruyn, Hugo ;
Tahmaseb, Ali .
PERIODONTOLOGY 2000, 2017, 73 (01) :121-133
[4]   3D printing in dentistry [J].
Dawood, A. ;
Marti, B. Marti ;
Sauret-Jackson, V. ;
Darwood, A. .
BRITISH DENTAL JOURNAL, 2015, 219 (11) :521-529
[5]   Registration of cone beam computed tomography data and intraoral surface scans - A prerequisite for guided implant surgery with CAD/CAM drilling guides [J].
Flugge, Tabea ;
Derksen, Wiebe ;
te Poel, Jobine ;
Hassan, Bassam ;
Nelson, Katja ;
Wismeijer, Daniel .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) :1113-1118
[6]   Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques [J].
Hazeveld, Aletta ;
Slater, James J. R. Huddleston ;
Ren, Yijin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (01) :108-115
[7]   Accuracy of a computerized tomography-guided template-assisted implant placement system: an in vitro study [J].
Horwitz, Jacob ;
Zuabi, Otman ;
Machtei, Eli E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) :1156-1162
[8]   Inaccuracies in additive manufactured medical skull models caused by the DICOM to STL conversion process [J].
Huotilainen, Eero ;
Jaanimets, Risto ;
Valasek, Jiri ;
Marcian, Petr ;
Salmi, Mika ;
Tuomi, Jukka ;
Makitie, Antti ;
Wolff, Jan .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (05) :E259-E265
[9]  
Kalt G, 2008, Int J Comput Dent, V11, P213
[10]   Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery [J].
Komiyama, Ai ;
Klinge, Bjoern ;
Hultin, Margareta .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (07) :677-685