Metal Artifact Reduction by Dual-Energy Computed Tomography Using Energetic Extrapolation A Systematically Optimized Protocol

被引:137
|
作者
Meinel, Felix G. [1 ]
Bischoff, Bernhard [1 ]
Zhang, Qiaowei [2 ]
Bamberg, Fabian [1 ]
Reiser, Maximilian F. [1 ]
Johnson, Thorsten R. C. [1 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Dept Radiol, Hangzhou 310003, Zhejiang, Peoples R China
关键词
metal implants; metal artifacts; dual-energy CT; dual-source CT; energetic extrapolation; CONE-BEAM CT; BONE REMOVAL; RENAL MASSES; IN-VITRO; ANGIOGRAPHY; PROJECTIONS; MULTISLICE; EXPERIENCE; IMPLANTS;
D O I
10.1097/RLI.0b013e31824c86a3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Energetic extrapolation is a promising strategy to reduce metal artifacts in dual-source computed tomography (DSCT). We performed this study to systematically optimize image acquisition parameters for this approach in a hip phantom and assess its value in a clinical study. Materials and Methods: Titanium and steel hip prostheses were placed in a standard hip phantom and a water tank and scanned on a DSCT scanner. Tube spectra, tube current ratio, collimation, pitch, and rotation time were optimized in a stepwise process. Artifacts were quantified by measuring the standard deviation of the computed tomography density in a doughnut-shaped region of interest placed around the prosthesis. A total of 22 adult individuals with metallic implants referred for computed tomography for a musculoskeletal indication were scanned using the optimized protocol. Degree of artifacts and diagnostic image quality were rated visually (0-10) and maximum streak intensity was measured. Results: Sn140/100 kVp proved superior to Sn140/80 kVp. There was a benefit for increasing tube current ratio from 1:1 to 3:1, but not beyond, in favor of the Sn140 kVp spectrum. Artifacts were less severe for a collimation of 32 x 0.6 mm as compared with 40 x 0.6 mm. A pitch of 0.5 at a rotation time of 0.5 seconds per rotation was preferable to other combinations with comparable scanning times. In the clinical study, increasing the extrapolated photon energy from 64 to 120 keV decreased the severity of artifacts from 8.0 to 2.0 (P < 0.001) and decreased streak intensity from 871 to 153 HU (P < 0.001). The median diagnostic image quality rating improved from 2.5 to 8.0 (P < 0.001). The median energy level visually perceived as optimal for diagnostic evaluation was 113 keV (range, 100-130 keV). Conclusions: Sn140/100 kVp with a tube current ratio of 3:1, a collimation of 32 x 0.6 mm, and extrapolated energies of 105 to 120 keV are optimal parameters for a dedicated DSCT protocol that effectively reduces metal artifacts by energetic extrapolation. The protocol effectively reduces metal artifacts in all types of metal implants. The optimized reconstructions yielded relevant additional findings.
引用
收藏
页码:406 / 414
页数:9
相关论文
共 50 条
  • [41] Unenhanced Dual-Energy Computed Tomography Visualization of Brain Edema
    Mohammed, Mohammed F.
    Marais, Olivia
    Min, Adam
    Ferguson, David
    Jalal, Sabeena
    Khosa, Faisal
    O'Keeffe, Michael
    O'Connell, Tim
    Schmiedeskamp, Heiko
    Krauss, Bernhard
    Rohr, Axel
    Nicolaou, Savvas
    INVESTIGATIVE RADIOLOGY, 2018, 53 (02) : 63 - 69
  • [42] Metal Artifact Reduction in Computed Tomography by Constrained Optimization
    Zhang, Xiaomeng
    Wang, Jing
    Xing, Lei
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [43] Dual-Energy Computed Tomography-How Accurate Is Gemstone Spectrum Imaging Metal Artefact Reduction? Its Application to Orthopedic Metal Implants
    Dabirrahmani, Dane
    Magnussen, John
    Appleyard, Richard Charles
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (06) : 925 - 935
  • [44] Radiotherapy planning of spine and pelvis using single-energy metal artifact reduction corrected computed tomography sets
    Ignatius, Daliya
    Alkhatib, Zaid
    Rowshanfarzad, Pejman
    Goodall, Simon
    Ibrahim, Mounir
    Hirst, Andrew
    Croxford, Riley
    Dass, Joshua
    Sabet, Mahsheed
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26
  • [45] Reduction of metal artifacts from unilateral hip arthroplasty on dual-energy CT with metal artifact reduction software
    Yue, Dong
    Rong, Cheng Fan
    Ning, Cai
    Liang, Hu
    Lian, Liu Ai
    Xin, Wang Ru
    Hong, Luo Ya
    ACTA RADIOLOGICA, 2018, 59 (07) : 853 - 860
  • [46] Dual-energy Computed Tomography in Coronary Artery Calcium Scoring
    Abhijith, S.
    Jaseemudheen, M. M.
    HEART VIEWS, 2024, 25 (02): : 74 - 79
  • [47] Strategies to Improve Image Quality on Dual-Energy Computed Tomography
    Patel, Bhavik N.
    Marin, Daniele
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 641 - +
  • [48] Cardiac Applications of Dual-Energy Computed Tomography
    Lempel, Matthew
    Frishman, William H.
    CARDIOLOGY IN REVIEW, 2019, 27 (04) : 208 - 210
  • [49] Dual-Energy Computed Tomography Applications in Neurointervention
    Wolman, Dylan N.
    Patel, Bhavik P.
    Wintermark, Max
    Heit, Jeremy J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 831 - 839
  • [50] Dual-Energy Computed Tomography Image Acquisition, Processing, and Workflow
    Megibow, Alec J.
    Kambadakone, Avinash
    Ananthakrishnan, Lakshmi
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 507 - +