Metal Artifact Reduction by Dual-Energy Computed Tomography Using Energetic Extrapolation A Systematically Optimized Protocol

被引:138
作者
Meinel, Felix G. [1 ]
Bischoff, Bernhard [1 ]
Zhang, Qiaowei [2 ]
Bamberg, Fabian [1 ]
Reiser, Maximilian F. [1 ]
Johnson, Thorsten R. C. [1 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Dept Radiol, Hangzhou 310003, Zhejiang, Peoples R China
关键词
metal implants; metal artifacts; dual-energy CT; dual-source CT; energetic extrapolation; CONE-BEAM CT; BONE REMOVAL; RENAL MASSES; IN-VITRO; ANGIOGRAPHY; PROJECTIONS; MULTISLICE; EXPERIENCE; IMPLANTS;
D O I
10.1097/RLI.0b013e31824c86a3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Energetic extrapolation is a promising strategy to reduce metal artifacts in dual-source computed tomography (DSCT). We performed this study to systematically optimize image acquisition parameters for this approach in a hip phantom and assess its value in a clinical study. Materials and Methods: Titanium and steel hip prostheses were placed in a standard hip phantom and a water tank and scanned on a DSCT scanner. Tube spectra, tube current ratio, collimation, pitch, and rotation time were optimized in a stepwise process. Artifacts were quantified by measuring the standard deviation of the computed tomography density in a doughnut-shaped region of interest placed around the prosthesis. A total of 22 adult individuals with metallic implants referred for computed tomography for a musculoskeletal indication were scanned using the optimized protocol. Degree of artifacts and diagnostic image quality were rated visually (0-10) and maximum streak intensity was measured. Results: Sn140/100 kVp proved superior to Sn140/80 kVp. There was a benefit for increasing tube current ratio from 1:1 to 3:1, but not beyond, in favor of the Sn140 kVp spectrum. Artifacts were less severe for a collimation of 32 x 0.6 mm as compared with 40 x 0.6 mm. A pitch of 0.5 at a rotation time of 0.5 seconds per rotation was preferable to other combinations with comparable scanning times. In the clinical study, increasing the extrapolated photon energy from 64 to 120 keV decreased the severity of artifacts from 8.0 to 2.0 (P < 0.001) and decreased streak intensity from 871 to 153 HU (P < 0.001). The median diagnostic image quality rating improved from 2.5 to 8.0 (P < 0.001). The median energy level visually perceived as optimal for diagnostic evaluation was 113 keV (range, 100-130 keV). Conclusions: Sn140/100 kVp with a tube current ratio of 3:1, a collimation of 32 x 0.6 mm, and extrapolated energies of 105 to 120 keV are optimal parameters for a dedicated DSCT protocol that effectively reduces metal artifacts by energetic extrapolation. The protocol effectively reduces metal artifacts in all types of metal implants. The optimized reconstructions yielded relevant additional findings.
引用
收藏
页码:406 / 414
页数:9
相关论文
共 28 条
[1]   Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering [J].
Bal, Matthieu ;
Spies, Lothar .
MEDICAL PHYSICS, 2006, 33 (08) :2852-2859
[2]   Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429
[3]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[4]   Evaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography [J].
Boas, F. Edward ;
Fleischmann, Dominik .
RADIOLOGY, 2011, 259 (03) :894-902
[5]  
Buie V.C., 2010, Vital Health Stat, V13
[6]   Dual-Energy Computed Tomography for the Detection of Late Enhancement in Reperfused Chronic Infarction A Comparison to Magnetic Resonance Imaging and Histopathology in a Porcine Model [J].
Deseive, Simon ;
Bauer, Ralf W. ;
Lehmann, Ralf ;
Kettner, Mattias ;
Kaiser, Christina ;
Korkusuz, Huedayi ;
Tandi, Christa ;
Theisen, Alf ;
Schaechinger, Volker ;
Schoepf, U. Joseph ;
Vogl, Thomas J. ;
Kerl, J. Matthias .
INVESTIGATIVE RADIOLOGY, 2011, 46 (07) :450-456
[7]   Quantification of Liver Fat in the Presence of Iron and Iodine An Ex-Vivo Dual-Energy CT Study [J].
Fischer, Michael A. ;
Gnannt, Ralph ;
Raptis, Dimitri ;
Reiner, Caecilia S. ;
Clavien, Pierre-Alain ;
Schmidt, Bernhard ;
Leschka, Sebastian ;
Alkadhi, Hatem ;
Goetti, Robert .
INVESTIGATIVE RADIOLOGY, 2011, 46 (06) :351-358
[8]   Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Bader, Markus ;
Staehler, Michael ;
Haseke, Nicolas ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Stief, Christian G. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2008, 43 (02) :112-119
[9]   Single-Phase Dual- Energy CT Allows for Characterization of Renal Masses as Benign or Malignant [J].
Graser, Anno ;
Becker, Christoph R. ;
Staehler, Michael ;
Clevert, Dirk A. ;
Macari, Michael ;
Arndt, Niko ;
Nikolaou, Konstantin ;
Sommer, Wieland ;
Stief, Christian ;
Reiser, Maximilian F. ;
Johnson, Thorsten R. C. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (07) :399-405
[10]   Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440