Dynamic and Wireless Sensing Measurements of Potentiometric Glucose Biosensor Based on Graphene and Magnetic Beads

被引:25
作者
Chou, Jung-Chuan [1 ]
Chen, Ruei-Ting [2 ]
Liao, Yi-Hung [3 ]
Chen, Jian-Syun [2 ]
Huang, Min-Siang [4 ]
Chou, Hsueh-Tao [1 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Grad Sch Elect Engn, Dept Elect Engn, Touliu 64002, Taiwan
[2] Natl Yunlin Univ Sci & Technol, Grad Sch Elect Engn, Touliu 64002, Taiwan
[3] TransWorld Univ, Dept Informat Management, Touliu 640, Taiwan
[4] Natl Yunlin Univ Sci & Technol, Dept Elect Engn, Touliu 64002, Taiwan
关键词
Glucose biosensor; ruthenium dioxide; magnetic bead; graphene; microfluidic device; wireless sensing system; ZigBee; DIRECT ELECTRON-TRANSFER; MICROFLUIDIC FRAMEWORK; SENSOR; ZIGBEE; OXIDASE; NANOCOMPOSITE; NANOPARTICLES; PERFORMANCE; FABRICATION; COMPOSITE;
D O I
10.1109/JSEN.2015.2449906
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the arrayed flexible pH sensor and glucose biosensor modified by magnetic beads and graphene were proposed. The ruthenium dioxide (RuO2) sensing films were deposited by radio frequency sputtering system and the screen-printed technique was used to construct the silver conducting wires and insulation layer of the RuO2 electrodes. In order to enhance performance of the pH sensor and glucose biosensor, the microfluidic device had been utilized and developed. In the measurement processes, the different pH and glucose solutions were investigated in various flow rates. According to the experimental results, the average sensitivity of the pH sensor was enhanced from 52.280 to 57.981 mV/pH and the average sensitivity of the RuO2/graphene/magnetic bead-GO(x)-Nafion glucose biosensor was enhanced from 10.628 to 13.541 mV/mM. With regard to the wireless sensing measurements, the wireless sensing system which complied the ZigBee standard was employed to transmit the signals of the pH or glucose measurements in this investigation, and the system consisted of the Xbee device, Arduino Mega 2560, readout circuit, pH or glucose biosensor and computer. According to the experimental results, the average sensitivity and linearity of the pH sensor were 51.063 mV/pH and 0.988, respectively, and the average sensitivity and linearity of the RuO2/graphene/magnetic bead-GOx-Nafion glucose biosensor were 11.005 mV/mM and 0.995, respectively.
引用
收藏
页码:5718 / 5725
页数:8
相关论文
共 38 条
[1]   A fast and sensitive potentiometric glucose microsensor based on glucose oxidase coated ZnO nanowires grown on a thin silver wire [J].
Ali, Syed M. Usman ;
Nur, O. ;
Willander, M. ;
Danielsson, B. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (02) :869-874
[2]   Pneumatic impulsion device for microfluidic systems [J].
Aracil, Carmen ;
Quero, Jose M. ;
Luque, Antonio ;
Miguel Moreno, J. ;
Perdigones, Francisco .
SENSORS AND ACTUATORS A-PHYSICAL, 2010, 163 (01) :247-254
[3]   An Overview and Assessment of Wireless Technologies and Co-existence of ZigBee, Bluetooth and Wi-Fi Devices [J].
Challoo, R. ;
Oladeinde, A. ;
Yilmazer, N. ;
Ozcelik, S. ;
Challoo, L. .
COMPLEX ADAPTIVE SYSTEMS 2012, 2012, 12 :386-391
[4]  
Chen J.-T., 2014, THESIS NAT YUNLIN U
[5]  
Chen R. T., 2014, P 19 ANN C CHEM SENS, P27
[6]  
Cheng T.-Y., 2013, THESIS NAT YUNLIN U
[7]  
Chou J. C., 2014, P INT EL DEV MAT S I, P1
[8]   Fabrication and Characteristic Analysis of a Remote Real-Time Monitoring Applied to Glucose Sensor System Based on Microfluidic Framework [J].
Chou, Jung-Chuan ;
Chen, Jia-Liang ;
Liao, Yi-Hung ;
Chen, Jie-Ting ;
Lin, Chin-Yi ;
Lin, Jyun-Wun ;
Jhang, Chiung-Yun ;
Chen, Ruei-Ting .
IEEE SENSORS JOURNAL, 2015, 15 (06) :3234-3240
[9]   Fabrication of Arrayed Flexible Screen-Printed Glucose Biosensor Based on Microfluidic Framework [J].
Chou, Jung-Chuan ;
Tsai, Ya-Li ;
Cheng, Tsung-Yi ;
Liao, Yi-Hung ;
Ye, Guan-Chen ;
Yang, Shu-Ying .
IEEE SENSORS JOURNAL, 2014, 14 (01) :178-183
[10]   Glucose biosensor of ruthenium-doped TiO2 sensing electrode by co-sputtering system [J].
Chou, Jung-Chuan ;
Yang, Hung-Yu ;
Chen, Cheng-Wei .
MICROELECTRONICS RELIABILITY, 2010, 50 (05) :753-756