Multi-Resin Masked Stereolithography (MSLA) 3D Printing for Rapid and Inexpensive Prototyping of Microfluidic Chips with Integrated Functional Components

被引:33
作者
Ahmed, Isteaque [1 ]
Sullivan, Katherine [1 ]
Priye, Aashish [1 ]
机构
[1] Univ Cincinnati, Dept Chem & Environm Engn, Cincinnati, OH 45221 USA
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 08期
关键词
3D printing; microfluidics; stereolithography; microfluidic valve; microfluidic pump; resin; GLASS; MICROFABRICATION; FABRICATION; HYDROGELS; FUTURE;
D O I
10.3390/bios12080652
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stereolithography based 3D printing of microfluidics for prototyping has gained a lot of attention due to several advantages such as fast production, cost-effectiveness, and versatility over traditional photolithography-based microfabrication techniques. However, existing consumer focused SLA 3D printers struggle to fabricate functional microfluidic devices due to several challenges associated with micron-scale 3D printing. Here, we explore the origins and mechanism of the associated failure modes followed by presenting guidelines to overcome these challenges. The prescribed method works completely with existing consumer class inexpensive SLA printers without any modifications to reliably print PDMS cast microfluidic channels with channel sizes as low as similar to 75 mu m and embedded channels with channel sizes as low similar to 200 mu m. We developed a custom multi-resin formulation by incorporating Polyethylene glycol diacrylate (PEGDA) and Ethylene glycol polyether acrylate (EGPEA) as the monomer units to achieve micron sized printed features with tunable mechanical and optical properties. By incorporating multiple resins with different mechanical properties, we were able to achieve spatial control over the stiffness of the cured resin enabling us to incorporate both flexible and rigid components within a single 3D printed microfluidic chip. We demonstrate the utility of this technique by 3D printing an integrated pressure-actuated pneumatic valve (with flexible cured resin) in an otherwise rigid and clear microfluidic device that can be fabricated in a one-step process from a single CAD file. We also demonstrate the utility of this technique by integrating a fully functional finger-actuated microfluidic pump. The versatility and accessibility of the demonstrated fabrication method have the potential to reduce our reliance on expensive and time-consuming photolithographic techniques for microfluidic chip fabrication and thus drastically lowering our barrier to entry in microfluidics research.
引用
收藏
页数:17
相关论文
共 62 条
[1]   The application of 3D printing in anatomy education [J].
AbouHashem, Yousef ;
Dayal, Manisha ;
Savanah, Stephane ;
Strkalj, Goran .
MEDICAL EDUCATION ONLINE, 2015, 20
[2]   Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations [J].
Alharbi, Nawal ;
Osman, Reham ;
Wismeijer, Daniel .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06) :760-767
[3]  
American Cleanroom Systems Admin Clean Room Classifications & ISO Standards, QUOTES 48 HOURS
[4]  
[Anonymous], SOFT LITHOGRAPHY AN
[5]  
[Anonymous], STEREOLITHOGRAPHY RE
[6]  
[Anonymous], FUSED DEPOSITION MOD
[7]  
[Anonymous], POLYM CHAIN AN OVERV
[8]  
[Anonymous], POLY ETHYLENE GLYCOL
[9]   3D-Printed Microfluidics [J].
Au, Anthony K. ;
Huynh, Wilson ;
Horowitz, Lisa F. ;
Folch, Albert .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (12) :3862-3881
[10]   Mail-order microfluidics: evaluation of stereolithography for the production of microfluidic devices [J].
Au, Anthony K. ;
Lee, Wonjae ;
Folch, Albert .
LAB ON A CHIP, 2014, 14 (07) :1294-1301