Ultrasensitive detection of L-cysteine using gold-5-amino-2-mercapto-1,3,4-thiadiazole core-shell nanoparticles film modified electrode

被引:32
作者
Kannan, Palanisamy [1 ,2 ]
John, S. Abraham [1 ]
机构
[1] Gandhigram Rural Univ, Dept Chem, Gandhigram 624302, Dindigul, India
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 637457, Singapore
关键词
Gold-aminomercaptothiadiazole core-shell nanoparticles; Cysteine sensor; Amperometric detection; Real sample analysis; GLASSY-CARBON ELECTRODE; PERFORMANCE LIQUID-CHROMATOGRAPHY; LASER-INDUCED FLUORESCENCE; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL DETERMINATION; CAPILLARY-ELECTROPHORESIS; PRECOLUMN DERIVATIZATION; COBALT PHTHALOCYANINE; CONDUCTING POLYMERS; AMINO-ACIDS;
D O I
10.1016/j.bios.2011.09.027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We are reporting the selective, sensitive and stable determination of L-cysteine (CV) at physiological pH (pH = 7.2) using a gold-aminomercaptothiadiazole core-shell nanoparticles (p-GAMCS NPs) film modified GC electrode. The p-GAMCS NPs film was fabricated on GC electrode by potentiodynamic method using 5-amino-2-mercapto-1,3,4-thiadiazole stabilized gold nanoparticles (AMT-AuNPs). The fabricated p-GAMCS NPs film was characterized by cyclic voltammetry and atomic force microscopy (AFM) techniques. The AFM image of the p-GAMCS NPs film showed that it contains a homogeneously distributed AuNPs with a spherical shape of similar to 10nm. The p-GAMCS NPs film modified GC electrode was exploited for the determination of CV. The bare GC electrode failed to show any response for CV (pH = 7.2) whereas p-GAMCS NPs film on GC electrode showed a well-defined oxidation peak for CV at 0.51 V. Further, p-GAMCS NPs film modified electrode successfully resolved the voltammetric signals of ascorbic acid (AA) and CV with a peak separation of 500 mV. This is the first report for the large voltammetric peak separation between CY and AA to the best of our knowledge. The amperometric current was increased linearly from 10 nM to 140 nM CV with a detection limit of 3 pM (S/N = 3). The present modified electrode showed better recoveries for spiked CV into the human blood serum and urine samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:276 / 281
页数:6
相关论文
共 44 条
[1]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[2]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[3]   Amino acid analysis in five pooled single plant cell samples using capillary electrophoresis coupled to laser-induced fluorescence detection [J].
Arlt, K ;
Brandt, S ;
Kehr, J .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (02) :319-325
[4]   Selective sensing of cysteine on manganese dioxide nanowires and chitosan modified glassy carbon electrodes [J].
Bai, Yu-Hui ;
Xu, Jing-Juan ;
Chen, Hong-Yuan .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (10) :2985-2990
[5]   The determination of cysteine at Bi-powder carbon paste electrodes by cathodic stripping voltammetry [J].
Baldrianova, L. ;
Agrafiotou, P. ;
Svancara, I. ;
Vytras, K. ;
Sotiropouios, S. .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (06) :918-921
[6]   Electrocatalytic oxidation and sensitive detection of cysteine at layer-by-layer assembled carbon nanotube-modified electrode [J].
Chen, X ;
Yang, Y ;
Ding, MY .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :52-56
[7]   Determination of cysteine in human plasma by high-performance liquid chromatography and ultraviolet detection after pre-column derivatization with 2-chloro-1-methylpyridinium iodide [J].
Chwatko, G ;
Bald, E .
TALANTA, 2000, 52 (03) :509-515
[8]   Electrochemical behavior of cysteine at a CuGeO3 nanowires modified glassy carbon electrode [J].
Dong, YongPing ;
Pei, LiZhai ;
Chu, XiangFeng ;
Zhang, WangBing ;
Zhang, QianFeng .
ELECTROCHIMICA ACTA, 2010, 55 (18) :5135-5141
[9]   Sensing of L-cysteine at glassy carbon electrode using Nile blue A as a mediator [J].
Ensafi, Ali A. ;
Behyan, Shirin .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) :282-288
[10]   Electrochemical response of new carbon electrodes bulk modified with cobalt phthalocyanine to some thiols in the presence of heptane or human urine [J].
Filanovsky, B .
ANALYTICA CHIMICA ACTA, 1999, 394 (01) :91-100