Disturbance observer control for AC speed servo with improved noise attenuation

被引:4
作者
Vonkomer, J. [1 ]
Belai, I. [2 ]
Huba, M. [2 ]
机构
[1] VONSCH Sro, R&D, Software, Brezno Mazornikovo, Slovakia
[2] STU FEI Bratislava, Bratislava, Slovakia
关键词
PI control; disturbance observer; AC speed servo drive; performance; robustness; noise attenuation; PI CONTROL; DESIGN; SYSTEM; RULES; MOTOR;
D O I
10.1016/j.ifacol.2017.08.841
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The paper deals with a noise attenuation design of a modification of the disturbance observer (DO) based PI control for an AC servo drive with the dominant first-order dynamics. The achieved results are compared with the traditional PI control. The DO based filtered PI (DO-FPI) controller consists of the P control with adjustable filter. It is augmented with an integral action based on load reconstruction using equally filtered plant dynamics inversion. The availability of broadly scalable filters requires a simple one-parameter based tuning. In looking for a possibly good noise attenuation, it allows changing the filter order and time constants by keeping nearly the same speed of disturbance responses as in the PI control. An application to the speed servo control with an incremental position sensor brings to light interesting properties of the compared solutions. The DO FPI and PI control give nearly equally robust solutions. However, in case of PI control it is at the expense of significantly increased torque ripple. (C) 2017, IFAC (International Federation of Automatic Control) Hosting by Elsevier Ltd. All rights reserved.
引用
收藏
页码:4300 / 4305
页数:6
相关论文
共 21 条
[1]  
Ackermann J., 2002, Robust Control. The Parameter Space Approach
[2]  
[Anonymous], ICM2015
[3]  
[Anonymous], AM CONTR C 2006
[4]  
Astrom K J., 2006, ISA - The Instrumentation, Systems and Automation Society
[5]  
Chu E. K., 2001, International Journal of Applied Mathematics and Computer Science, V11, P1035
[6]   Model-free control [J].
Fliess, Michel ;
Join, Cedric .
INTERNATIONAL JOURNAL OF CONTROL, 2013, 86 (12) :2228-2252
[7]   From PID to Active Disturbance Rejection Control [J].
Han, Jingqing .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (03) :900-906
[8]   Comparing 2DOF PI and predictive disturbance observer based filtered PI control [J].
Huba, M. .
JOURNAL OF PROCESS CONTROL, 2013, 23 (10) :1379-1400
[9]   Performance measures, performance limits and optimal PI control for the IPDT plant [J].
Huba, M. .
JOURNAL OF PROCESS CONTROL, 2013, 23 (04) :500-515
[10]  
Huba M, 2014, 2014 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), P1325, DOI 10.1109/SPEEDAM.2014.6871949