Although it has been more than 20 years since the first recorded use of a quantitative ultrasound (QUS) technology to predict bone fragility, the field has not yet reached its maturity. QUS has the potential to predict fracture risk in several clinical circumstances and has the advantages of being nonionizing, inexpensive, portable, highly acceptable to patients, and repeatable. However, the wide dissemination of QUS in clinical practice is still limited and suffering from the absence of clinical consensus on how to integrate QUS technologies in bone densitometry armamentarium. Several critical issues need to be addressed to develop the role of QUS within rheumatology. These include issues of technologies adapted to measure the central skeleton, data acquisition, and signal processing procedures to reveal bone properties beyond bone mineral quantity and elucidation of the complex interaction between ultrasound and bone structure. This article reviews the state-of-the-art in technological developments applied to assess bone strength in vivo. We describe generic measurement and signal processing methods implemented in clinical ultrasound devices, the devices and their practical use, and performance measures. The article also points out the present limitations, especially those related to the absence of standardization, and the lack of comprehensive theoretical models. We conclude with suggestions of future lines and trends in technology challenges and research areas such as new acquisition modes, advanced signal processing techniques, and modelization.
引用
收藏
页码:1179 / 1196
页数:18
相关论文
共 156 条
[11]   SHOULD BROAD-BAND ULTRASONIC-ATTENUATION BE NORMALIZED FOR THE WIDTH OF THE CALCANEUS [J].
BLAKE, GM ;
HERD, RJM ;
MILLER, CG ;
FOGELMAN, I .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (804) :1206-1209
[12]   Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography [J].
Bossy, E ;
Padilla, F ;
Peyrin, F ;
Laugier, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23) :5545-5556
[13]   Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models [J].
Bossy, E ;
Talmant, M ;
Laugier, P .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (05) :2314-2324
[14]   Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: A validation on test materials [J].
Bossy, E ;
Talmant, M ;
Defontaine, M ;
Patat, F ;
Laugier, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (01) :71-79
[15]   Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: A 2D simulation study [J].
Bossy, E ;
Talmant, M ;
Laugier, P .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 112 (01) :297-307
[16]   Attenuation in trabecular bone: A comparison between numerical simulation and experimental results in human femur [J].
Bossy, Emmanuel ;
Laugier, Pascal ;
Peyrin, Francoise ;
Padilla, Frederic .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (04) :2469-2475
[17]   Assessment of bone architecture with ultrasonometry:: Experimental and clinical experience [J].
Cadossi, R ;
de Terlizzi, F ;
Canè, V ;
Fini, M ;
Wüster, C .
HORMONE RESEARCH, 2000, 54 :9-18
[18]   In vivo performance evaluation of the Achilles Insight QUS device [J].
Cepollaro, C ;
Gonnelli, S ;
Montagnani, A ;
Caffarelli, C ;
Cadirni, A ;
Martini, S ;
Nuti, R .
JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (03) :341-346
[19]   In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz [J].
Chaffaï, S ;
Padilla, F ;
Berger, G ;
Laugier, P .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (03) :1281-1289
[20]   Frequency dependence of ultrasonic backscattering in cancellous bone:: Autocorrelation model and experimental results [J].
Chaffaï, S ;
Roberjot, V ;
Peyrin, F ;
Berger, G ;
Laugier, P .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (05) :2403-2411