Online Monitoring of Water Toxicity by Use of Bioluminescent Reporter Bacterial Biochips

被引:60
作者
Elad, Tal [1 ]
Almog, Ronen [2 ]
Yagur-Kroll, Sharon [1 ]
Levkov, Klimentiy [3 ]
Melamed, Sahar [1 ]
Shacham-Diamand, Yosi [2 ]
Belkin, Shimshon [1 ]
机构
[1] Hebrew Univ Jerusalem, Alexander Silberman Inst Life Sci, Dept Plant & Environm Sci, IL-91904 Jerusalem, Israel
[2] Tel Aviv Univ, George S Wise Fac Life Sci, Dept Phys Elect, Sch Elect Engn, IL-69978 Tel Aviv, Israel
[3] Tel Aviv Univ, George S Wise Fac Life Sci, Dept Mol Microbiol & Biotechnol, IL-69978 Tel Aviv, Israel
关键词
SALICYLATE BIOAVAILABILITY; BIOMONITORING SYSTEM; OPTICAL BIOSENSOR; QUANTIFICATION; IDENTIFICATION; NAPHTHALENE; EFFLUENT; SENSOR; PANEL;
D O I
10.1021/es202465c
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We describe a flow-through biosensor for online continuous water toxicity monitoring. At the heart of the device are disposable modular biochips incorporating agar-immobilized bioluminescent recombinant reporter bacteria, the responses of which are probed by single-photon avalanche diode detectors. To demonstrate the biosensor capabilities, we equipped it with biochips harboring both inducible and constitutive reporter strains and exposed it to a continuous water flow for up to 10 days. During these periods we challenged the biosensor with 2-h pulses of water spiked with model compounds representing different classes of potential water pollutants, as well as with a sample of industrial wastewater. The biosensor reporter panel detected all simulated contamination events within 0.5-2.5 h, and its response was indicative of the nature of the contaminating chemicals. We believe that a biosensor of the proposed design can be integrated into future water safety and security networks, as part of an early warning system against accidental or intentional water pollution by toxic chemicals.
引用
收藏
页码:8536 / 8544
页数:9
相关论文
共 39 条
[31]  
Shedd TR, 2001, B ENVIRON CONTAM TOX, V66, P392
[32]   Identification of β-lactam antibiotics using bioluminescent Escherichia coli and a support vector machine classifier algorithm [J].
Smolander, Olli-Pekka ;
Ribeiro, Andre S. ;
Yli-Harja, Olli ;
Karp, Matti .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (02) :604-609
[33]   Development of a set of simple bacterial biosensors for quantitative and rapid measurements of arsenite and arsenate in potable water [J].
Stocker, J ;
Balluch, D ;
Gsell, M ;
Harms, H ;
Feliciano, J ;
Daunert, S ;
Malik, KA ;
Van der Meer, JR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (20) :4743-4750
[34]   Development of a Multistrain Bacterial Bioreporter Platform for the Monitoring of Hydrocarbon Contaminants in Marine Environments [J].
Tecon, Robin ;
Beggah, Siham ;
Czechowska, Kamila ;
Sentchilo, Vladimir ;
Chronopoulou, Panagiota-Myrsini ;
McGenity, Terry J. ;
van der Meer, Jan Roelof .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (03) :1049-1055
[35]  
U.S. Environmental Protection Agency, 2009, NAT PRIM DRINK WAT R
[36]   Where microbiology meets microengineering: design and applications of reporter bacteria [J].
van der Meer, Jan Roelof ;
Belkin, Shimshon .
NATURE REVIEWS MICROBIOLOGY, 2010, 8 (07) :511-522
[37]  
WHO, 2008, GUID DRINK WAT QUAL
[38]   Upgrading bioluminescent bacterial bioreporter performance by splitting the lux operon [J].
Yagur-Kroll, Sharon ;
Belkin, Shimshon .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (04) :1071-1082
[39]   Strategies for enhancing bioluminescent bacterial sensor performance by promoter region manipulation [J].
Yagur-Kroll, Sharon ;
Bilic, Benny ;
Belkin, Shimshon .
MICROBIAL BIOTECHNOLOGY, 2010, 3 (03) :300-310