A novel application of normoxic polymer gel dosimeters for near real-time dose measurement using cone-beam computed tomography

被引:4
|
作者
Wu, Tung-Hsin [5 ]
Tsai, Chia-Jung [5 ]
Zhang, Geoffrey [4 ]
Yu, Chun-Yen [3 ]
Liang, Ji-An [3 ]
Wu, Jay [2 ]
Lee, Jason Js. [5 ]
Ho, Yung-Jen [1 ]
Huang, Tzung-Chi [1 ]
机构
[1] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung, Taiwan
[2] Cent Taiwan Univ Sci & Technol, Dept Radiol Technol, Taipei, Taiwan
[3] China Med Univ Hosp, Dept Radiat Oncol, Taichung, Taiwan
[4] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL USA
[5] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
关键词
Normoxic polymer gel dosimeter; CBCT; IGRT; Radiation dosimetry; DISTRIBUTIONS;
D O I
10.1016/j.nima.2010.06.188
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study is to evaluate the feasibility of using cone-beam CT system as a near real-time measurement device in dose estimation with normoxic polymer gel dosimetry (MAC). Each vial was filled with MAC gel and irradiated with uniform doses of 0-10 Gy to generate dose response curves. After irradiation, a cone-beam CT was used to perform the 3D dose measurement. In this study, two groups of gel samples were irradiated and measured in two ways for comparison: near real-time measurement, in which the gel phantom was read right after the irradiation, and delayed measurement, in which the measurement was performed 30 min, 4 h and 1 day after the irradiation for the gel phantom to be exposed to oxygen. All groups were also performed with and without a full bowtie filter to estimate the influence of a full bowtie filter to dose response. The linear dose response curves with and without a full bowtie filter for the four different CT imaging times were within a range 0.044-0.049 Delta N-CT cGy(-1) and 0.061-0.063 Delta N-CT cGy(-1), respectively, with no significant difference at different imaging times. Nevertheless, dose response curves with the full bowtie filter were higher than those without, with p-value <0.05 for all the different imaging times tested. Normoxic polymer gel dosimetry combined with cone-beam CT provides a useful method for near real-time dose measurement. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S279 / S281
页数:3
相关论文
共 50 条
  • [1] Conformal dose verification using cone beam optical computed tomography and polymer gel dosimeters: A feasibility study
    Schreiner, J
    Rogers, M
    Senden, R
    McAuley, K
    Miller, J
    MEDICAL PHYSICS, 2005, 32 (07) : 2427 - 2427
  • [2] Measurement of skin dose from cone-beam computed tomography imaging
    Sercan Akyalcin
    Jeryl D English
    Kenneth M Abramovitch
    Xiujiang J Rong
    Head & Face Medicine, 9
  • [3] Measurement of skin dose from cone-beam computed tomography imaging
    Akyalcin, Sercan
    English, Jeryl D.
    Abramovitch, Kenneth M.
    Rong, Xiujiang J.
    HEAD & FACE MEDICINE, 2013, 9
  • [4] Characterizing a novel scintillating glass for application to megavoltage cone-beam computed tomography
    Hu, Yue-Houng
    Shedlock, Daniel
    Wang, Adam
    Rottmann, Joerg
    Baturin, Paul
    Myronakis, Marios
    Huber, Pascal
    Fueglistaller, Rony
    Shi, Mengying
    Morf, Daniel
    Star-Lack, Josh
    Berbeco, Ross I.
    MEDICAL PHYSICS, 2019, 46 (03) : 1323 - 1330
  • [5] Assessing Placement Error of Optically Stimulated Luminescent in Vivo Dosimeters Using Cone-Beam Computed Tomography
    Riegel, A.
    Tariq, M.
    Gomez, C.
    Klein, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3536 - 3536
  • [6] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [7] Proton Online Adaptation Using Novel Cone-Beam Computed Tomography System
    Hao, Y.
    Hugo, G. D.
    Zhao, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E671 - E671
  • [8] Measurement of build-up region dose with optical cone-beam computed tomography scanner
    Garisto, Sarah
    Jordan, Kevin
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [9] Mathematical estimation and in vivo dose measurement for cone-beam computed tomography on prostate cancer patients
    Jeng, Shiu-Chen
    Tsai, Chiao-Ling
    Chan, Wen-Tung
    Tung, Chuan-Jong
    Wu, Jian-Kuen
    Cheng, Jason Chia-Hsien
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 (01) : 57 - 61
  • [10] Radiation dose reduction in cone-beam computed tomography of extremities: evaluation of a novel radiation shield
    Matikka, H. d
    Viren, T.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (02) : N57 - N63