Spatially resolved two-dimensional spectroscopy

被引:0
作者
Adalsteinsson, E [1 ]
Spielman, DM [1 ]
机构
[1] Stanford Univ, Dept Radiol, Richard M Lucas MRS Imaging Ctr, Radiol Sci Lab, Stanford, CA 94305 USA
关键词
spiral trajectories; two-dimensional spectroscopy; J-resolved spectroscopy;
D O I
10.1002/(SICI)1522-2594(199901)41:1<8::AID-MRM3>3.3.CO;2-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is presented to collect spatially resolved two-dimensional spectra on a conventional clinical scanner. Time-varying gradients during the readout period rapidly sample data simultaneously for two spatial and two spectral dimensions. The k-space trajectories are based on spiral paths that make efficient use of the gradient hardware. A gridding algorithm is used for reconstruction. With the spiral-based readout gradients, current single-voxel two-dimensional techniques can be extended to spatially resolved Volumetric acquisitions. The method is demonstrated with a two-dimensional J-resolved acquisition of a phantom with separate compartments of lactic acid and ethyl alcohol in water. Data were acquired with a spatial resolution of 18 x 18 pixels over a 24 cm field of view, 400 Hz spectral bandwidth in the chemical shift dimension with a 3.8 Hz resolution, and 50 Hz spectral bandwidth in the second frequency dimension with a 1.56 Hz resolution. Magn Reson Med 41:8-12, 1999. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 35 条
[1]   3-DIMENSIONAL SPECTROSCOPIC IMAGING WITH TIME-VARYING GRADIENTS [J].
ADALSTEINSSON, E ;
IRARRAZABAL, P ;
SPIELMAN, DM ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :461-466
[2]   Volumetric spectroscopic imaging with spiral-based k-space trajectories [J].
Adalsteinsson, E ;
Irarrazabal, P ;
Topp, S ;
Meyer, C ;
Macovski, A ;
Spielman, DM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :889-898
[3]  
ADALSTEINSSON E, 1996, P ISMRM 4 ANN M, P1222
[4]  
ADALSTEINSSON E, 1997, Patent No. 5652516
[5]   Gradient characterization using a Fourier-transform technique [J].
Alley, MT ;
Glover, GH ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :581-587
[6]   THE UNEQUIVOCAL DETERMINATION OF LACTIC-ACID USING A ONE-DIMENSIONAL ZERO-QUANTUM COHERENCE-TRANSFER TECHNIQUE [J].
DODDRELL, DM ;
BRERETON, IM ;
MOXON, LN ;
GALLOWAY, GJ .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :132-138
[7]   ON THE USE OF 2-DIMENSIONAL-J NMR MEASUREMENTS FOR IN-VIVO PROTON MRS - MEASUREMENT OF HOMONUCLEAR DECOUPLED SPECTRA WITHOUT THE NEED FOR SHORT ECHO TIMES [J].
DREHER, W ;
LEIBFRITZ, D .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :331-337
[8]   A DOUBLE QUANTUM COHERENCE TRANSFER PROTON NMR-SPECTROSCOPY TECHNIQUE FOR MONITORING STEADY-STATE TUMOR LACTIC-ACID LEVELS INVIVO [J].
FREEMAN, DM ;
SOTAK, CH ;
MULLER, HH ;
YOUNG, SW ;
HURD, RE .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :321-329
[9]   CHARACTERIZATION OF ATHEROSCLEROSIS WITH A 1.5-T IMAGING-SYSTEM [J].
GOLD, GE ;
PAULY, JM ;
GLOVER, GH ;
MORETTO, JC ;
MACOVSKI, A ;
HERFKENS, RJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02) :399-407
[10]   PEEP - A RAPID CHEMICAL-SHIFT IMAGING METHOD [J].
GUILFOYLE, DN ;
BLAMIRE, A ;
CHAPMAN, B ;
ORDIDGE, RJ ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (02) :282-287