Thermoeconomic analysis on a cascade energy utilization system for compression heat in air separation units

被引:28
|
作者
Rong, Yangyiming [1 ]
Zhi, Xiaoqin [1 ]
Wang, Kai [1 ]
Zhou, Xia [1 ]
Cheng, Xingwang [1 ]
Qiu, Limin [1 ]
Chi, Xuelin [2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[2] Hangzhou Oxygen Plant Grp Co Ltd, Hangzhou 310014, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Compression heat; Liquid desiccant dehumidification; Organic Rankine vapor compression; Cryogenic air separation unit; NATURAL-GAS LNG; CENTRIFUGAL-COMPRESSOR; EXERGY ANALYSIS; OPTIMAL-DESIGN; CO2; CAPTURE; POWER-PLANT; INTEGRATION; OPTIMIZATION; TECHNOLOGIES; PERFORMANCE;
D O I
10.1016/j.enconman.2020.112820
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of air compression is crucial to the overall efficiency of cryogenic air separation units. A cascade utilization system of compression heat (CUSCH) is proposed for air separation units, in which the compression heat is used in situ to improve the operating condition of the compressor through inlet air cooling and dehumidification. The compression heat of relatively higher-grade (> 75 degrees C) is used to drive an organic Rankine vapor compression (ORVC) refrigeration cycle for air cooling, while the remaining lower-grade heat (40-75 degrees C) is used to regenerate the desiccant solution for the dehumidification system. A thermodynamic model is built for the CUSCH and a case study is conducted based on a practical compression process for a 60,000-Nm(3)/ h scale air separation unit. The influences of air dehumidification and cooling on the compression performance are analyzed. The results indicate that the CUSCH not only reduces the compression power but also prevents water condensation in the compressors and heat exchangers, which is beneficial for operational safety. It is estimated that the proposed CUSCH can reduce about 4.9% of the total compression power, and the isothermal efficiency of air compressor is increased by about 5.0%. In addition, the CUSCH is economically viable and environmentally friendly compared with traditional compression systems, with a payback time of 5.0 years, a levelized cost of energy of 0.0339 $/kWh, and a CO2 emission reduction potential of 6340 tCO(2)/year, which shows its prospects for practical applications in particular for large scale air separation units.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Air Separation, flue gas compression and purification units for oxy-coal combustion systems
    Tranier, Jean-Pierre
    Dubettier, Richard
    Darde, Arthur
    Perrin, Nicolas
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 966 - 971
  • [32] Thermoeconomic and environmental feasibility of waste-to-energy combined heat and power units: a case study from Western Iran
    Taheri, Ramezan
    Nasrabadi, Touraj
    Yousefi, Hossein
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2022,
  • [33] Comparative thermoeconomic analysis of trigeneration systems based on absorption heat transformers for utilizing low-temperature geothermal energy
    Seyyedvalilu, M. Hatef
    Zare, V
    Mohammadkhani, F.
    ENERGY, 2021, 224
  • [34] Energy, entropy and cost analysis of a combined power and water system with cascade utilization of geothermal energy
    He, W. F.
    Han, D.
    Wen, T.
    ENERGY CONVERSION AND MANAGEMENT, 2018, 174 : 719 - 729
  • [35] Analysis of energy cascade utilization in the chemically precooled engine cycle from a perspective of indirect combustion
    Wang, Cong
    Huang, Hongyan
    Zhang, Junlong
    Fang, Jiwei
    Liu, Zekuan
    Qin, Jiang
    Shao, Jiahui
    FUEL, 2023, 334
  • [36] Analysis of multi-cascade CCHP system with gas turbine bypass extraction air energy storage
    Du, Jun
    Guo, Jing
    APPLIED THERMAL ENGINEERING, 2023, 232
  • [37] Design and analysis of LNG cold energy cascade utilization system integrating light hydrocarbon separation, organic Rankine cycle and direct cooling
    Pan, Jie
    Li, Mofan
    Li, Ran
    Tang, Linghong
    Bai, Junhua
    APPLIED THERMAL ENGINEERING, 2022, 213
  • [38] Using exergy analysis to reduce power consumption in air separation units for oxy-combustion processes
    Fu, Chao
    Gundersen, Truls
    ENERGY, 2012, 44 (01) : 60 - 68
  • [39] Exergy analysis of a one-stage adiabatic compressed air energy storage system
    Mozayeni, Hamidreza
    Wang, Xiaolin
    Negnevitsky, Michael
    2ND INTERNATIONAL CONFERENCE ON ENERGY AND POWER (ICEP2018), 2019, 160 : 260 - 267
  • [40] Heat Exchanger Network Synthesis Integrated with Compression-Absorption Cascade Refrigeration System
    Sun, Xiaojing
    Liu, Linlin
    Zhuang, Yu
    Zhang, Lei
    Du, Jian
    PROCESSES, 2020, 8 (02)