Thermoeconomic analysis on a cascade energy utilization system for compression heat in air separation units

被引:28
|
作者
Rong, Yangyiming [1 ]
Zhi, Xiaoqin [1 ]
Wang, Kai [1 ]
Zhou, Xia [1 ]
Cheng, Xingwang [1 ]
Qiu, Limin [1 ]
Chi, Xuelin [2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[2] Hangzhou Oxygen Plant Grp Co Ltd, Hangzhou 310014, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Compression heat; Liquid desiccant dehumidification; Organic Rankine vapor compression; Cryogenic air separation unit; NATURAL-GAS LNG; CENTRIFUGAL-COMPRESSOR; EXERGY ANALYSIS; OPTIMAL-DESIGN; CO2; CAPTURE; POWER-PLANT; INTEGRATION; OPTIMIZATION; TECHNOLOGIES; PERFORMANCE;
D O I
10.1016/j.enconman.2020.112820
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of air compression is crucial to the overall efficiency of cryogenic air separation units. A cascade utilization system of compression heat (CUSCH) is proposed for air separation units, in which the compression heat is used in situ to improve the operating condition of the compressor through inlet air cooling and dehumidification. The compression heat of relatively higher-grade (> 75 degrees C) is used to drive an organic Rankine vapor compression (ORVC) refrigeration cycle for air cooling, while the remaining lower-grade heat (40-75 degrees C) is used to regenerate the desiccant solution for the dehumidification system. A thermodynamic model is built for the CUSCH and a case study is conducted based on a practical compression process for a 60,000-Nm(3)/ h scale air separation unit. The influences of air dehumidification and cooling on the compression performance are analyzed. The results indicate that the CUSCH not only reduces the compression power but also prevents water condensation in the compressors and heat exchangers, which is beneficial for operational safety. It is estimated that the proposed CUSCH can reduce about 4.9% of the total compression power, and the isothermal efficiency of air compressor is increased by about 5.0%. In addition, the CUSCH is economically viable and environmentally friendly compared with traditional compression systems, with a payback time of 5.0 years, a levelized cost of energy of 0.0339 $/kWh, and a CO2 emission reduction potential of 6340 tCO(2)/year, which shows its prospects for practical applications in particular for large scale air separation units.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Optimizing Air Separation and LNG Cold Utilization: Energy Savings, Exergy Efficiency, and System Reliability
    Shingan, Bhalchandra
    Pujari, Murali
    Arya, Adarsh Kumar
    Singh, Varunpratap
    CHEMICAL ENGINEERING & TECHNOLOGY, 2024, 47 (09)
  • [22] Analysis of CO2 Emission and Economic Feasibility for a Heat-Integrated Air Separation System
    Cong, Lin
    Chang, Liang
    Liu, Xinggao
    Deng, Xiaogang
    Chen, Honglong
    CHEMICAL ENGINEERING & TECHNOLOGY, 2018, 41 (08) : 1639 - 1648
  • [23] Energy and exergy analysis for waste heat cascade utilization in sinter cooling bed
    Liu, Yan
    Yang, Jian
    Wang, Jin
    Cheng, Zhi-long
    Wang, Qiu-wang
    ENERGY, 2014, 67 : 370 - 380
  • [24] Energy and exergy analysis of a geothermal heat pump air conditioning system
    Baccoli, Roberto
    Mastino, Costantino
    Rodriguez, Giuseppe
    APPLIED THERMAL ENGINEERING, 2015, 86 : 333 - 347
  • [25] Thermoeconomic analysis of a standalone solar hydrogen system with hybrid energy storage
    Jafari, Moharrm
    Armaghan, Davoud
    Mahmoudi, S. M. Seyed
    Chitsaz, Ata
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (36) : 19614 - 19627
  • [26] Optimum design and exergy analysis of a novel cryogenic air separation process with LNG (liquefied natural gas) cold energy utilization
    Mehrpooya, Mehdi
    Sharifzadeh, Mohammad Mehdi Moftakhari
    Rosen, Marc A.
    ENERGY, 2015, 90 : 2047 - 2069
  • [27] Proposal and energy/exergy analysis of a novel cryogenic air separation configuration for the production of neon and argon
    Saaedi, Mehran
    Mehrpooya, Mehdi
    Delpishe, Mostafa
    Zaitsev, Andrew
    CHEMICAL PAPERS, 2022, 76 (11) : 7075 - 7093
  • [28] Simulation and Analysis of Cryogenic Air Separation Process with LNG Cold Energy Utilization
    Xiong, Yongqiang
    Hua, Ben
    CHEMICAL, MATERIAL AND METALLURGICAL ENGINEERING III, PTS 1-3, 2014, 881-883 : 653 - +
  • [29] Potential for Energy Utilization of Air Compression Section Using an Open Absorption Refrigeration System
    Ye, Bicui
    Sun, Shufei
    Wang, Zheng
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [30] Superstructure-Based Simultaneous Optimization of a Heat Exchanger Network and a Compression-Absorption Cascade Refrigeration System for Heat Recovery
    Sun, Xiaojing
    Liu, Linlin
    Dong, Yachao
    Zhuang, Yu
    Zhang, Lei
    Du, Jian
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (36) : 16017 - 16028