This chapter will present experimental data from studies in test cells, and from monitoring indoor temperatures in un-occupied and in occupied buildings, when data was available, regardless of the dates of the research, not just recent research. In many cases where sufficiently measured data of the outdoor and the indoor temperatures was available, formulas have been generated, expressing the indoor temperatures of the building or the test model as a function of the outdoor temperatures. In cases where long-term monitoring has been conducted, predicting formulas were generated: data from one period was used for the generation of the formulas while the data other period was used for their validation. All the formulas represent the experimental data and conditions of the various studies. They are not intended to be used for general prediction of the performance of the tested passive cooling system. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1692 / 1726
页数:35
相关论文
共 32 条
[1]  
[Anonymous], INT SOL EN SOC AM SO
[2]  
[Anonymous], P ANN C AM SOL EN SO
[3]  
CHAVEZ JRG, 2007, PLEA 2007 SING
[4]  
Clinton J, PALA PASSIVE SOLAR P
[5]  
CUNNIGHAN WA, 1986, P PASS LOW EN ARCH P
[6]   A multi-stage down-draft evaporative cool tower for semi-enclosed spaces: Aerodynamic performance [J].
Erell, Evyatar ;
Pearlmutter, David ;
Etzion, Yair .
SOLAR ENERGY, 2008, 82 (05) :420-429
[7]  
GIVONI B, 2009, ASES 2009 C BUFF NY
[8]  
GIVONI B, 2004, ASES 2004 C PORTL OR
[9]  
GIVONI B, 2005, ISES 2005 C ORL FLOR
[10]  
Givoni B., 1994, PASSIVE LOW ENERGY C