Anterior sacrospinous ligament fixation associated with paravaginal repair using the Pinnacle™ device: an anatomical study

被引:10
作者
Cayrac, Melanie [1 ]
Letouzey, Vincent [1 ]
Ouzaid, Idir [2 ]
Costa, Pierre [3 ]
Delmas, Vincent [2 ,4 ]
de Tayrac, Renaud [1 ]
机构
[1] Caremeau Univ Hosp, Dept Obstet & Gynaecol, F-30029 Nimes 9, France
[2] Hop Xavier Bichat, Dept Urol, Paris, France
[3] Caremeau Univ Hosp, Dept Urol, F-30029 Nimes 9, France
[4] Paris Descartes Univ, Dept Anat, EA4465, Paris, France
关键词
Anterior sacrospinous ligament fixation; Capio (TM) suture capture device; Genital prolapse; Polypropylene mesh; STRESS URINARY-INCONTINENCE; VAGINAL VAULT SUSPENSION; PROLAPSE; TRANSOBTURATOR; COLPOPEXY;
D O I
10.1007/s00192-011-1554-5
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The objective of this paper is to study the reproducibility and anatomical risks of anterior sacrospinous ligament (SSL) fixation associated with paravaginal repair using the Pinnacle (TM) device (Boston Scientific (TM)). Simplified bilateral anterior SSL fixation associated with paravaginal fixation through the arcus tendineus fascia pelvis (ATFP) was performed on five fresh cadavers using the Pinnacle (TM) device. Cadaver dissection was then performed by open pelvic surgery. Eight SSL and ten ATFP were available for analysis. SSL fixations were optimal in four cases, too superficial in three cases, and too high in one case. Mean distance between SSL fixation and ischial spine was 18.6 mm (range 10 to 30 mm). Mean distance between SSL fixation and pudendal nerve was 6.5 mm (range 0 to 15 mm). ATFP fixations were optimal in five cases, good in four cases, and too superficial in one case. In one case (10%), the middle arm of the prosthesis was in contact with the ureter and traction on that arm resulted in ureteral kinking. Anterior SSL fixation associated with paravaginal repair using the Pinnacle (TM) device was not reproducible every time in this cadaver study. These results confirm the need for specific training before starting anterior SSL fixations.
引用
收藏
页码:335 / 340
页数:6
相关论文
共 19 条
[1]  
AMARENCO G, 1987, PRESSE MED, V16, P399
[2]   The obturator foramen: The intersection of all the dangers? [J].
Bader, G. .
GYNECOLOGIE OBSTETRIQUE & FERTILITE, 2009, 37 (09) :687-688
[3]   Intraligamentous nerves as a potential source of pain after sacrospinous ligament fixation of the vaginal apex [J].
Barksdale P.A. ;
Gasser R.F. ;
Gauthier C.M. ;
Elkins T.E. ;
Wall L.L. .
International Urogynecology Journal, 1997, 8 (3) :121-125
[4]   Surgical techniques for vault prolapse: a review of the literature [J].
Beer, M ;
Kuhn, A .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2005, 119 (02) :144-155
[5]   Bilateral anterior sacrospinous ligament suspension associated with a paravaginal repair with mesh: short-term clinical results of a pilot study [J].
de Tayrac, Renaud ;
Boileau, Laurent ;
Fara, Jean-Francois ;
Monneins, Francois ;
Raini, Charles ;
Costa, Pierre .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2010, 21 (03) :293-298
[6]  
Estrade J-P, 2005, J Gynecol Obstet Biol Reprod (Paris), V34, P481
[7]   Anterior or posterior sacrospinous vaginal vault suspension: Long-term anatomic and functional evaluation [J].
Goldberg, RP ;
Tomezsko, JE ;
Winkler, HA ;
Koduri, S ;
Culligan, PJ ;
Sand, PK .
OBSTETRICS AND GYNECOLOGY, 2001, 98 (02) :199-204
[8]   Persistent groin pain following a trans-obturator sling procedure for stress urinary incontinence: a diagnostic and therapeutic challenge [J].
Hazewinkel, Menke H. ;
Hinoul, Piet ;
Roovers, Jan-Paul .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2009, 20 (03) :363-365
[9]   Transobturator and retropubic tape procedures in stress urinary incontinence: a systematic review and meta-analysis of effectiveness and complications [J].
Latthe, P. M. ;
Foon, R. ;
Toozs-Hobson, P. .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2007, 114 (05) :522-531
[10]   Update on the epidemiology of genital prolapse [J].
Lousquy, R. ;
Costa, P. ;
Delmas, V. ;
Haab, F. .
PROGRES EN UROLOGIE, 2009, 19 (13) :907-915