Comparability of oscillometric to simultaneous auscultatory blood pressure measurement in children

被引:3
|
作者
Ringrose, Jennifer S. [1 ,4 ]
Alabbas, Abdullah [2 ]
Jalali, Afrooz [1 ]
Khinda, Harsimran [3 ]
Morgan, Catherine [2 ]
Yiu, Verna [2 ]
Alexander, R. Todd [2 ,4 ]
Padwal, Raj [1 ,5 ]
机构
[1] Univ Alberta, Dept Med, Edmonton, AB, Canada
[2] Univ Alberta, Dept Pediat, Edmonton, AB, Canada
[3] Univ Alberta, Fac Sci, Edmonton, AB, Canada
[4] Women & Childrens Hlth Res Inst, Edmonton, AB, Canada
[5] Mazankowski Heart Inst, Edmonton, AB, Canada
关键词
auscultatory; blood pressure measurement; children; hypertension; oscillometry; HYPERTENSION; GUIDELINES; STATEMENT; DIAGNOSIS;
D O I
10.1097/MBP.0000000000000367
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective Uncertainty exists regarding the accuracy of automated blood pressure (BP) measurement in children. We recorded oscillometric waveforms in children, derived oscillometric BPs using two standard algorithms, and compared the results to simultaneous auscultation. Patients and methods Twenty children aged 2-12 years were recruited from a tertiary-care Pediatric Nephrology Clinic. Sex, height, weight, arm circumference, history of hypertension, and clinic BP were recorded. Two, simultaneously measured, oscillometric and auscultatory BP readings were obtained 30-60 s apart. The first reading was discarded and, the second, used for analyses. Fixed-ratio and slope-based algorithms were used for BP derivation. Results Mean age was 7.95 +/- 2.82 years, 40% were female, mean arm circumference was 21.86 +/- 4.06 cm, and 50% had hypertension or a history of hypertension. Mean auscultatory BP for all participants (systolic +/- SD/diastolic +/- SD) was 93.40 +/- 11.80/50.50 +/- 9.04 mmHg, oscillometric fixed-ratio BP was 99.20 +/- 11.90/57.35 +/- 7.15 mmHg and oscillometric slope-based algorithm was 91.60 +/- 13.94/60.65 +/- 7.71 mmHg. Compared to auscultation, the fixed-ratio method differed by 5.80 +/- 12.72/6.85 +/- 7.51 mmHg (P=0.06 and <0.01) and the slope-based method differed by -1.80 +/- 13.59/10.15 +/- 8.07 mmHg (P=0.56 and <0.01). Differences from auscultation were statistically significant for diastolic BP with both fixed-ratio and slope-based methods for all age categories but of greatest magnitude in the youngest children. Conclusion Oscillometric BP derived using two commonly used algorithms differed by more than 5 mmHg in either systolic BP or diastolic BP from simultaneous auscultatory BP in children aged 2-11. These findings emphasize the need for greater understanding of the functionality and accuracy of oscillometry in children.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 50 条
  • [1] Comparability of Oscillometric to Simultaneous Auscultatory Blood Pressure Measurement in Children.
    Ringrose, Jennifer S.
    Alabbas, Abdullah
    Jalali, Afrooz
    Khinda, Harsimran
    Morgan, Catherine
    Yiu, Verna
    Alexander, R. T.
    Padwal, Raj
    HYPERTENSION, 2018, 72
  • [2] COMPARISON BETWEEN OSCILLOMETRIC AND AUSCULTATORY BLOOD PRESSURE MEASUREMENT IN CHILDREN AND ADOLESCENTS
    Duzova, Ali
    Baskin, Esra
    Cakar, Nilgun
    Soylemezoglu, Oguz
    Yalcinkaya, Fatos
    Hayran, Mutlu
    PEDIATRIC NEPHROLOGY, 2018, 33 (10) : 1818 - 1819
  • [3] Auscultatory versus oscillometric measurement of blood pressure in octogenarians
    Rosholm, Jens-Ulrik
    Arnspang, Sidsel
    Matzen, Lars
    Jacobsen, Ib A.
    BLOOD PRESSURE, 2012, 21 (05) : 269 - 272
  • [4] EFFECT OF UNDERCUFFING ON AUSCULTATORY AND OSCILLOMETRIC BLOOD PRESSURE MEASUREMENT
    Albuquerque, Nila
    Padwal, Raj
    Araujo, Thelma
    JOURNAL OF HYPERTENSION, 2021, 39 : E130 - E130
  • [5] Comparison of Automated Oscillometric Versus Auscultatory Blood Pressure Measurement
    Landgraf, Johanna
    Wishner, Stanley H.
    Kloner, Robert A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (03): : 386 - 388
  • [6] Oscillometric and auscultatory blood pressure measurement in the assessment of blood pressure and target organ damage
    Johansson, Jouni K.
    Puukka, Pauli J.
    Jula, Antti M.
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 6 - 13
  • [7] Oscillometric and auscultatory blood pressure measurement methods in children: a systematic review and meta-analysis
    Duncombe, Stephanie L.
    Voss, Christine
    Harris, Kevin C.
    JOURNAL OF HYPERTENSION, 2017, 35 (02) : 213 - 224
  • [8] Blood pressure measurement by oscillometric and auscultatory methods in normotensive pregnant women
    Vigato, Estefanie Siqueira
    Tatagiba Lamas, Jose Luiz
    REVISTA BRASILEIRA DE ENFERMAGEM, 2019, 72 : 162 - 169
  • [9] Can auscultatory blood pressure normative values be used for evaluation of oscillometric blood pressure in children?
    Sulakova, Terezie
    Sulakova, Astrida
    Strnadel, Jiri
    Pavlicek, Jan
    Obermannova, Barbora
    Feber, Janusz
    JOURNAL OF CLINICAL HYPERTENSION, 2017, 19 (04): : 381 - 387
  • [10] Automatic blood pressure measurement: the oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    JOURNAL OF HYPERTENSION, 2008, 26 (01) : 35 - 43