Two-dimensional readout of GEM detectors

被引:93
|
作者
Bressan, A
De Oliveira, R
Gandi, A
Labbé, JC
Ropelewski, L
Sauli, F [1 ]
Mörmann, D
Müller, T
Simonis, HJ
机构
[1] CERN, Div EP, CH-1211 Geneva 23, Switzerland
[2] Univ Karlsruhe, Inst Expt Kernphys, D-7500 Karlsruhe, Germany
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1999年 / 425卷 / 1-2期
关键词
gas electron multiplier; pick-up electrodes; X-rays and charged particles;
D O I
10.1016/S0168-9002(98)01405-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The recently introduced gas electron multiplier (GEM) permits the amplification of electrons released by ionizing radiation in a gas by factors approaching ten thousand; larger gains can be obtained combining two GEMs in cascade. We describe methods for implementing two- and three-dimensional projective localization of radiation, with submillimeter accuracy, making use of specially manufactured and patterned pick-up electrodes. Easy to implement and flexible in the choice of the readout geometry, the technology has the distinctive advantage of allowing all pick-up electrodes to be kept at ground potential, thus substantially improving the system simplicity and reliability. Preliminary results demonstrating the two-dimensional imaging capability of the devices are provided and discussed, as well as future perspectives of development. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:254 / 261
页数:8
相关论文
共 50 条
  • [41] Two-dimensional numerical simulation of HgCdTe infrared detectors
    Jo, NH
    Yoo, SD
    Ko, BG
    Lee, SW
    Jang, J
    Lee, SD
    Kwack, KD
    INFRARED TECHNOLOGY AND APPLICATIONS XXIV, PTS 1-2, 1998, 3436 : 50 - 60
  • [42] Two-Dimensional X-ray Diffraction Detectors
    Blanton, Tom
    SPECTROSCOPY, 2016, 31 (07) : 42 - 43
  • [43] Two-dimensional infrared and terahertz detectors: Outlook and status
    Rogalski, A.
    Kopytko, M.
    Martyniuk, P.
    APPLIED PHYSICS REVIEWS, 2019, 6 (02):
  • [44] Design and optimization of resistive anode for a two-dimensional imaging GEM detector
    鞠旭东
    董明义
    赵逸琛
    周传兴
    欧阳群
    Chinese Physics C, 2016, (08) : 94 - 99
  • [45] Design and optimization of resistive anode for a two-dimensional imaging GEM detector
    Ju, Xu-Dong
    Dong, Ming-Yi
    Zhao, Yi-Chen
    Zhou, Chuan-Xing
    Qun Ou-Yang
    CHINESE PHYSICS C, 2016, 40 (08)
  • [46] Design and optimization of resistive anode for a two-dimensional imaging GEM detector
    鞠旭东
    董明义
    赵逸琛
    周传兴
    欧阳群
    Chinese Physics C, 2016, 40 (08) : 94 - 99
  • [47] Pixel readout for GEM detectors based on switched field effect transistor array
    Zheng, Xiaocui
    Li, Yulan
    Lai, Yongfang
    Li, Jin
    Li, Yuanjing
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2007, 47 (06): : 855 - 858
  • [48] CHARACTERISTICS AND READOUT OF AN INSB CID TWO-DIMENSIONAL SCANNING TDI ARRAY
    WANG, SCH
    WEI, CY
    WOODBURY, HH
    GIBBONS, MD
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1985, 32 (08) : 1599 - 1607
  • [49] Readout of GEM detectors using the Medipix2 CMOS pixel chip
    Bamberger, A.
    Desch, K.
    Renz, U.
    Titov, M.
    Vlasov, N.
    Wienemann, P.
    Zwerger, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (03): : 361 - 370
  • [50] High two-dimensional arrays based on resistive charge division readout
    Alfieri, S
    De Cesare, N
    Grassi, D
    Perillo, E
    Spadaccini, G
    Vigilante, M
    Dusi, W
    Amann, M
    Koebel, JM
    Siffert, P
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 317 - 327