Technetium-99m methoxy isobutyl isonitrile (MIBI) imaging of the parathyroid glands in patients with renal failure

被引:24
作者
Chesser, AMS
Carroll, MC
Lightowler, C
Macdougall, IC
Britton, KE
Baker, LRI
机构
[1] UNIV LONDON ST BARTHOLOMEWS HOSP MED COLL,DEPT NEPHROL,LONDON EC1A 7BE,ENGLAND
[2] UNIV LONDON ST BARTHOLOMEWS HOSP MED COLL,DEPT NUCL MED,LONDON EC1A 7BE,ENGLAND
关键词
hyperplasia; imaging; parathyroid; renal failure; technetium-99m methoxy isobutyl isonitrile;
D O I
10.1093/ndt/12.1.97
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Technetium-99m methoxy isobutyl isonitrile (Tc-99m MIBI) scintigraphy has been reported to be at least as reliable as thallium-technetium subtraction imaging in the preoperative localization of hyperplastic parathyroid glands in patients with renal failure. Reports have suggested that 50% of glands can be identified correctly by this method. The aim of this study was to improve on previous results and demonstrate that Tc-99m MIBI imaging has an important place in the preoperative work-up of these patients. Methods. Eighteen patients on renal replacement therapy were studied. All had tertiary hyperparathyroidism and had Tc-99m MIBI imaging prior to parathyroidectomy. A refined reporting method was employed. The imaging results were compared to the subsequent surgical and histological findings. Results. In the 12 patients in whom serum parathyroid hormone levels fell postoperatively to within or below the normal range, 38 of 46 glands (82.6%) were correctly identified and located in the correct quadrant of the thyroid gland. There were two false positive results where the imaging predicted glands not subsequently found by the surgeon. In the patients who had postoperative hyperparathyroidism, repeat Tc-99m MIBI imaging was able to locate accurately the site of the residual parathyroid tissue. Conclusions. Tc-99m MIBI imaging is able to identify more than 80% of hyperplastic parathyroid glands in renal failure patients if this reporting process is used, and locate them in the correct quadrant of the thyroid gland. Tc-99m MIBI imaging is of particular value when re-exploration of the neck is required for post-parathyroidectomy hyperparathyroidism. These results represent a significant improvement on the sensitivity of this imaging technique when compared to previous published data.
引用
收藏
页码:97 / 100
页数:4
相关论文
共 10 条
[1]  
ADALET I, 1994, EUR J NUCL MED, V21, P509
[2]   The accuracy of parathyroid gland localization in primary hyperparathyroidism using sestamibi radionuclide imaging [J].
Johnston, LB ;
Carroll, MJ ;
Britton, KE ;
Lowe, DG ;
Shand, W ;
Besser, GM ;
Grossman, AB .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1996, 81 (01) :346-352
[3]  
LIGHTOWLER C, 1995, NEPHROL DIAL TRANSPL, V10, P1372
[4]  
ODOHERTY MJ, 1992, J NUCL MED, V33, P313
[5]   A CLINICAL AUDIT OF THALLIUM TECHNETIUM SUBTRACTION PARATHYROID SCANS [J].
SAMANTA, A ;
WILSON, B ;
IQBAL, J ;
BURDEN, AC ;
WALLS, J ;
COSGRIFF, P .
POSTGRADUATE MEDICAL JOURNAL, 1990, 66 (776) :441-445
[6]  
TAILLEFER R, 1992, J NUCL MED, V33, P1801
[7]   EVALUATION OF IMAGE-DIAGNOSING METHODS OF ENLARGED PARATHYROID-GLANDS IN CHRONIC-RENAL-FAILURE [J].
TAKAGI, H ;
TOMINAGA, Y ;
UCHIDA, K ;
YAMADA, N ;
KAWAI, M ;
KANO, T ;
FUNAHASHI, H ;
MIZUNO, S .
WORLD JOURNAL OF SURGERY, 1986, 10 (04) :605-611
[8]   PREOPERATIVE LOCALIZATION OF PARATHYROID TISSUE WITH TC-99M SESTAMIBI I-123 SUBTRACTION SCANNING [J].
THULE, P ;
THAKORE, K ;
VANSANT, J ;
MCGARITY, W ;
WEBER, C ;
PHILLIPS, LS .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1994, 78 (01) :77-82
[9]  
WEBER CJ, 1993, SURGERY, V114, P1011
[10]   PREOPERATIVE IMAGING OF ABNORMAL PARATHYROID-GLANDS IN PATIENTS WITH HYPERPARATHYROID DISEASE USING COMBINATION TC-99M-PERTECHNETATE AND TC-99M-SESTAMIBI RADIONUCLIDE SCANS [J].
WEI, JP ;
BURKE, GJ ;
MANSBERGER, AR .
ANNALS OF SURGERY, 1994, 219 (05) :568-573