Non-Contact, Simple Neonatal Monitoring by Photoplethysmography

被引:34
作者
Cobos-Torres, Juan-Carlos [1 ]
Abderrahim, Mohamed [2 ]
Martinez-Orgado, Jose [3 ]
机构
[1] Catholic Univ Cuenca, Postgrad Subdirect, 4X8V 5F, Cuenca, Ecuador
[2] Univ Carlos III Madrid, Dept Syst Engn & Automat, Leganes 28911, Spain
[3] San Carlos Clin Hosp, Neonatol, Madrid 28040, Spain
关键词
image processing; neonatology; imaging photoplethysmography; vital signs; respiratory sinus arrhythmia; HEART-RATE; INFANTS; MOVEMENT;
D O I
10.3390/s18124362
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents non-contact vital sign monitoring in neonates, based on image processing, where a standard color camera captures the plethysmographic signal and the heart and breathing rates are processed and estimated online. It is important that the measurements are taken in a non-invasive manner, which is imperceptible to the patient. Currently, many methods have been proposed for non-contact measurement. However, to the best of the authors' knowledge, it has not been possible to identify methods with low computational costs and a high tolerance to artifacts. With the aim of improving contactless measurement results, the proposed method based on the computer vision technique is enhanced to overcome the mentioned drawbacks. The camera is attached to an incubator in the Neonatal Intensive Care Unit and a single area in the neonate's diaphragm is monitored. Several factors are considered in the stages of image acquisition, as well as in the plethysmographic signal formation, pre-filtering and filtering. The pre-filter step uses numerical analysis techniques to reduce the signal offset. The proposed method decouples the breath rate from the frequency of sinus arrhythmia. This separation makes it possible to analyze independently any cardiac and respiratory dysrhythmias. Nine newborns were monitored with our proposed method. A Bland-Altman analysis of the data shows a close correlation of the heart rates measured with the two approaches (correlation coefficient of 0.94 for heart rate (HR) and 0.86 for breath rate (BR)) with an uncertainty of 4.2 bpm for HR and 4.9 for BR (k = 1). The comparison of our method and another non-contact method considered as a standard independent component analysis (ICA) showed lower central processing unit (CPU) usage for our method (75% less CPU usage).
引用
收藏
页数:14
相关论文
共 25 条
[1]   Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - A pilot study [J].
Aarts, Lonneke A. M. ;
Jeanne, Vincent ;
Cleary, John P. ;
Lieber, C. ;
Nelson, J. Stuart ;
Oetomo, Sidarto Bambang ;
Verkruysse, Wim .
EARLY HUMAN DEVELOPMENT, 2013, 89 (12) :943-948
[2]   Neonatal non-contact respiratory monitoring based on real-time infrared thermography [J].
Abbas, Abbas K. ;
Heimann, Konrad ;
Jergus, Katrin ;
Orlikowsky, Thorsten ;
Leonhardt, Steffen .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[3]  
Aminian K., 1992, P 14 ANN INT C IEEE, P2633
[4]  
Ángeles-Castellanos Manuel, 2013, Rev. Fac. Med. (Méx.), V56, P26
[5]  
[Anonymous], 2012, THESIS PRINCETON U P
[6]  
Balaguer Gargallo M, 2007, An Pediatr (Barc), V67, P133
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   A Hybrid Radar-Camera Sensing System With Phase Compensation for Random Body Movement Cancellation in Doppler Vital Sign Detection [J].
Gu, Changzhan ;
Wang, Guochao ;
Li, Yiran ;
Inoue, Takao ;
Li, Changzhi .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (12) :4678-4688
[10]   Novel health monitoring method using an RGB camera [J].
Hassan, M. A. ;
Malik, A. S. ;
Fofi, D. ;
Saad, N. ;
Meriaudeau, F. .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (11) :4838-4854