Functional Characteristics and Mechanical Performance of PCU Composites for Knee Meniscus Replacement

被引:24
作者
Inyang, Adijat Omowumi [1 ]
Vaughan, Christopher Leonard [1 ]
机构
[1] Univ Cape Town, Fac Hlth Sci, Human Biol Dept, Div Biomed Engn, Anzio Rd, ZA-7925 Cape Town, South Africa
关键词
composite; fibers; polycarbonate-urethane; meniscal replacement; mechanical properties; meniscus; FIBER-REINFORCED SCAFFOLD; MOLECULAR-WEIGHT POLYETHYLENE; POLYVINYL ALCOHOL-HYDROGEL; OVINE ARTHROPLASTY MODEL; UHMWPE ACETABULAR CUPS; IN-VITRO; SURFACE MODIFICATION; WEAR-RESISTANCE; MEDIAL MENISCUS; PART-II;
D O I
10.3390/ma13081886
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The potential use of fiber-reinforced based polycarbonate-urethanes (PCUs) as candidate meniscal substitutes was investigated in this study. Mechanical test pieces were designed and fabricated using a compression molding technique. Ultra-High Molecular Weight Polyethylene (UHMWPE) fibers were impregnated into PCU matrices, and their mechanical and microstructural properties evaluated. In particular, the tensile moduli of the PCUs were found unsuitable, since they were comparatively lower than that of the meniscus, and may not be able to replicate the inherent role of the meniscus effectively. However, the inclusion of fibers produced a substantial increment in the tensile modulus, to a value within a close range measured for meniscus tissues. Increments of up to 227% were calculated with a PCU fiber reinforcement composite. The embedded fibers in the PCU composites enhanced the fracture mechanisms by preventing the brittle failure and plastic deformation exhibited in fractured PCUs. The behavior of the composites in compression varied with respect to the PCU matrix materials. The mechanical characteristics demonstrated by the developed PCU composites suggest that fiber reinforcements have a considerable potential to duplicate the distinct and multifaceted biomechanical roles of the meniscus.
引用
收藏
页数:16
相关论文
共 82 条
[1]  
Abbot A., 2003, The Adult Knee, V1, P81
[2]   Design characteristics for the tissue engineering of cartilaginous tissues [J].
Almarza, AJ ;
Athanasiou, KA .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (01) :2-17
[3]  
[Anonymous], WILEY ENCY BIOMEDICA
[4]  
[Anonymous], ADV TOPICS SCI TECHN
[5]  
[Anonymous], ORTHOP BIOMATERIALS
[6]  
[Anonymous], JOINT REPLACEMENT HI
[7]  
[Anonymous], THESIS
[8]   The physio-mechanical properties of recycled low density polyethylene (RLDPE)/bean pod ash particulate composites [J].
Atuanya, C. U. ;
Edokpia, R. O. ;
Aigbodion, V. S. .
RESULTS IN PHYSICS, 2014, 4 :88-95
[9]   Design and mechanical evaluation of a novel fiber-reinforced scaffold for meniscus replacement [J].
Balint, Eric ;
Gatt, Charles J., Jr. ;
Dunn, Michael G. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2012, 100A (01) :195-202
[10]   Actifit® synthetic meniscal substitute: Experience with 18 patients in Brest, France [J].
Baynat, C. ;
Andro, C. ;
Vincent, J. P. ;
Schiele, P. ;
Buisson, P. ;
Dubrana, F. ;
Gunepin, F. X. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (08) :S385-S389