Continuous comprehensive two-dimensional liquid chromatography-electrospray ionization mass spectrometry of complex lipidomic samples

被引:53
|
作者
Holcapek, Michal [1 ]
Ovcacikova, Magdalena [1 ]
Lisa, Miroslav [1 ]
Cifkova, Eva [1 ]
Hajek, Tomas [1 ]
机构
[1] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, Pardubice 53210, Czech Republic
关键词
Lipids; Lipidomics; Comprehensive 2D liquid chromatography; Mass spectrometry; Plasma; Brain; HYDROPHILIC INTERACTION; SILVER-ION; SHOTGUN LIPIDOMICS; HUMAN PLASMA; FATTY-ACID; IN-LINE; TRIACYLGLYCEROL; ORTHOGONALITY; OPTIMIZATION; QUANTITATION;
D O I
10.1007/s00216-015-8528-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new continuous comprehensive two-dimensional liquid chromatography-electrospray ionization mass spectrometry method has been developed for the lipidomic characterization of complex biological samples. The reversed-phase ultra-high-performance liquid chromatography with a C-18 column (150 mm x 1 mm, 1.7 mu m) used in the first dimension makes the separation of numerous lipid species differing in their hydrophobic part of the molecule, mainly fatty acyl chain lengths and the number and positions of double bonds, possible. Coeluted lipid species in the first dimension are resolved by the fast hydrophilic interaction liquid chromatography separation (50 mm x 3 mm, 2.7 mu m, core-shell particles) of lipid classes according to their different polarities in the second dimension. Retention times in both dimensions, accurate m/z values, and tandem mass spectra provide high confidence in the identification of lipid species. The retention behavior of individual lipids in reversed-phase mode follows the equivalent carbon number pattern, which provides an additional tool for unambiguous identification. This analytical method is applied for the lipidomic characterization of total lipid extracts of human plasma and porcine brain samples, which resulted in the identification of 143 lipid species from four lipid categories and ten lipid classes.
引用
收藏
页码:5033 / 5043
页数:11
相关论文
共 50 条
  • [11] Determination of Fatty Acids in Beef by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Laiel C. Soliman
    Elizabeth M. Andrucson
    Kingsley K. Donkor
    John S. Church
    Bruno Cinel
    Food Analytical Methods, 2016, 9 : 630 - 637
  • [12] Determination of Fatty Acids in Beef by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Soliman, Laiel C.
    Andrucson, Elizabeth M.
    Donkor, Kingsley K.
    Church, John S.
    Cinel, Bruno
    FOOD ANALYTICAL METHODS, 2016, 9 (03) : 630 - 637
  • [13] Liquid chromatography-electrospray ionization mass spectrometry for the simultaneous quantitation of collagen and elastin crosslinks
    Naffa, Rafea
    Holmes, Geoff
    Ahn, Meekyung
    Harding, David
    Norris, Gillian
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1478 : 60 - 67
  • [14] Qualitative Analysis of Plant-Derived Samples by Liquid Chromatography-Electrospray Ionization-Quadrupole-Time of Flight-Mass Spectrometry
    Jiang, Yun-Bin
    Zhong, Mei
    Peng, Wei
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2015, 14 (05) : 925 - 930
  • [15] Quantitation of paclitaxel and its two major metabolites using a liquid chromatography-electrospray ionization tandem mass spectrometry
    Zhang, Wei
    Dutschman, Ginger E.
    Li, Xin
    Cheng, Yung-Chi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (22): : 2018 - 2022
  • [16] Two-dimensional analysis of phenolic acids in seedling roots by high performance liquid chromatography-electrospray ionization-ion mobility spectrometry
    Lu, Yaling
    Guo, Jianpeng
    Yu, Jianna
    Guo, Jianheng
    Jia, Xu
    Liu, Wenjie
    Tian, Pingfang
    ANALYTICAL METHODS, 2019, 11 (05) : 610 - 617
  • [17] CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD
    Derezinski, Pawel
    Klupczynska, Agnieszka
    Sawicki, Wojciech
    Kokot, Zenon J.
    ACTA POLONIAE PHARMACEUTICA, 2016, 73 (02): : 303 - 313
  • [18] CYP2D6 genotyping by liquid chromatography-electrospray ionization mass spectrometry
    Beer, Beate
    Erb, Robert
    Pitterl, Florian
    Niederstaetter, Harald
    Maronas, Olalla
    Gesteira, Alejandro
    Carracedo, Angel
    Piatkov, Irina
    Oberacher, Herbert
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (08) : 2361 - 2370
  • [19] Liquid chromatography-electrospray ionization mass spectrometry for simultaneous detection of mtDNA length and nucleotide polymorphisms
    Oberacher, Herbert
    Niederstaetter, Harald
    Parson, Walther
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2007, 121 (01) : 57 - 67
  • [20] Quantification of zolmitriptan in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Zhang, ZJ
    Xu, FG
    Tian, Y
    Li, W
    Mao, GG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 227 - 233