Two-dimensional porphyrin-based covalent organic framework: A novel platform for sensitive epidermal growth factor receptor and living cancer cell detection

被引:133
作者
Yan, Xu [1 ]
Song, Yingpan [2 ]
Liu, Jiameng [2 ]
Zhou, Nan [1 ]
Zhang, Chunlin [1 ]
He, Linghao [2 ]
Zhang, Zhihong [2 ]
Liu, Zhongyi [3 ]
机构
[1] Zhengzhou Univ, Dept Orthoped, Affiliated Hosp 1, 1,Jianshe East Rd, Zhengzhou 450052, Henan, Peoples R China
[2] Zhengzhou Univ Light Ind, Henan Prov Key Lab Surface & Interface Sci, 136,Sci Ave, Zhengzhou 450001, Henan, Peoples R China
[3] Zhengzhou Univ, Coll Chem & Mol Engn, Zhengzhou 450000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Porphyrin-based covalent organic framework; Electrochemical aptasensor; Detection of epidermal growth factor receptor; Living cancer cell detection; ELECTROCHEMICAL IMMUNOSENSOR; SELECTIVE DETECTION; GOLD NANOPARTICLES; LUNG-CANCER; APTASENSOR; BIOMARKER; BIOSENSORS; SURFACE; ELECTRODE; EGFR;
D O I
10.1016/j.bios.2018.11.047
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A porphyrin-based covalent organic framework (denoted as p-COF) was synthesized by a simple oil-bath method and exploited as a novel sensing layer for immobilizing epidermal growth factor receptor (EGFR)-targeting aptamer strands to detect trace EGFR and living michigan cancer foundation-7 (MCF-7) cells for the first time. p-COF presented a nanosheet-like structure, large cavities, rich nitrogen-bearing groups, high electrochemical activity, excellent bioaffinity, low toxicity, and good stability in aqueous solution; the microstructural features of this material enabled strong immobilization of the aptamer strands. Interactions between the aptamer strands and EGFR significantly changed the electrochemical signals of the modified electrode due to the formation of an aptamer-EGFR complex. The p-COF-based aptasensor exhibited an extremely low detection limit (LOD) of 5.64 fg.mL.(-1) obtained from differential pulse voltammetry and 7.54 fg.mL(-1) originated from electrochemical impedance spectroscopy with a broad linear detection range of 0.05-100 pg.mL(-1) of the EGFR concentration. When detecting living MCF-7 cells, the p-COF-based aptasensor showed an LOD of 61 cell.mL(-1) with a linear detection range of 500 x 10(5) cell.mL(-1). The fabricated aptasensor exhibited high selectivity, good stability, reproducibility, acceptable recyclability, and favorable applicability in human serum samples. We believe that the developed p-COF-based aptasensor is a potential candidate for the sensitive detection of target cancer markers or living cells.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 59 条
[1]   Capacitive aptasensor based on interdigitated electrode for breast cancer detection in undiluted human serum [J].
Arya, Sunil K. ;
Zhurauski, Pavel ;
Jolly, Pawan ;
Batistuti, Marina R. ;
Mulato, Marcelo ;
Estrela, Pedro .
BIOSENSORS & BIOELECTRONICS, 2018, 102 :106-112
[2]   Electrochemiluminescence Detection of Escherichia coli 0157:H7 Based on a Novel Polydopamine Surface Imprinted Polymer Biosensor [J].
Chen, Shufan ;
Chen, Xueqian ;
Zhang, Lijuan ;
Gao, Juanjuan ;
Ma, Qiang .
ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (06) :5430-5436
[3]   Nanoparticle Probes for the Detection of Cancer Biomarkers, Cells, and Tissues by Fluorescence [J].
Chinen, Alyssa B. ;
Guan, Chenxia M. ;
Ferrer, Jennifer R. ;
Barnaby, Stacey N. ;
Merkel, Timothy J. ;
Mirkin, Chad A. .
CHEMICAL REVIEWS, 2015, 115 (19) :10530-10574
[4]   Evaluation of human epidermal growth factor receptor 2 in breast cancer with a novel specific aptamer [J].
Chu, ming ;
Kang, Jia-rui ;
Wang, Wei ;
Li, Haichao ;
Feng, Jia-hui ;
Chu, Zheng-yun ;
Zhang, Ming-bo ;
Xu, Lan ;
Wang, Yue-dan .
CELLULAR & MOLECULAR IMMUNOLOGY, 2017, 14 (04) :398-400
[5]  
Cohen Roger B, 2003, Clin Colorectal Cancer, V2, P246, DOI 10.3816/CCC.2003.n.006
[6]   Electrochemical aptamer-based biosensor developed to monitor PSA and VEGF released by prostate cancer cells [J].
Crulhas, Bruno P. ;
Karpik, Agnieszka E. ;
Delella, Flavia K. ;
Castro, Gustavo R. ;
Pedrosa, Valber A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (29) :6771-6780
[7]   Ordered covalent organic frameworks, COFs and PAFs. From preparation to application [J].
Diaz, Urbane ;
Corma, Avelino .
COORDINATION CHEMISTRY REVIEWS, 2016, 311 :85-124
[8]   Thioether-Based Fluorescent Covalent Organic Framework for Selective Detection and Facile Removal of Mercury(II) [J].
Ding, San-Yuan ;
Dong, Ming ;
Wang, Ya-Wen ;
Chen, Yan-Tao ;
Wang, Huai-Zhen ;
Su, Cheng-Yong ;
Wang, Wei .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2016, 138 (09) :3031-3037
[9]   Electrochemical impedance immunosensor based on gold nanoparticles-protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue [J].
Elshafey, Reda ;
Tavares, Ana C. ;
Siaj, Mohamed ;
Zourob, Mohammed .
BIOSENSORS & BIOELECTRONICS, 2013, 50 :143-149
[10]   An electrochemical immunosensor for detection of a breast cancer biomarker based on antiHER2-iron oxide nanoparticle bioconjugates [J].
Emami, Mahdi ;
Shamsipur, Mojtaba ;
Saber, Reza ;
Irajirad, Rasoul .
ANALYST, 2014, 139 (11) :2858-2866