Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film

被引:4
作者
Lee, Chung Il [1 ]
Yoon, Sei-Chul [1 ]
Shin, Jae Won [2 ]
Hong, Seung-Woo [2 ]
Suh, Tae Suk [3 ]
Min, Kyung Joo [4 ]
Lee, Sang Deok [2 ,5 ]
Chung, Su Mi [6 ]
Jung, Jae-Yong [7 ]
机构
[1] Catholic Univ Korea, Dept Radiat Oncol, Bucheon St Marys Hosp, Bucheon 420717, South Korea
[2] Sungkyunkwan Univ, Dept Phys, Suwon 440746, South Korea
[3] Catholic Univ, Dept Biomed Engn, Seoul 137701, South Korea
[4] Sungkyunkwan Univ, Dept Energy Sci, Suwon 440746, South Korea
[5] Gimcheon Univ, Dept Optometry, Gimcheon 740704, South Korea
[6] Catholic Univ Korea, Dept Radiat Oncol, Yeouido St Marys Hosp, Bucheon 420717, South Korea
[7] Inje Univ, Sanggye Paik Hosp, Dept Radiat Oncol, Seoul 139707, South Korea
基金
新加坡国家研究基金会;
关键词
Heterogeneity; CyberKnife; GEANT4; Gafchromic EBT2 film; Small photon beams; MONTE-CARLO SIMULATIONS; RADIOCHROMIC FILM; ENERGY-DEPENDENCE; RADIOSURGERY; ACCURACY; NEUTRONS; DETECTOR; THERAPY; FIELDS; MODEL;
D O I
10.3938/jkps.66.1308
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Percentage depth dose (PDD) distributions in heterogeneous phantoms with lung and soft bone equivalent media are studied by using the GEANT4 Monte Carlo code. For lung equivalent media, Balsa wood is used, and for soft bone equivalent media, a compound material with epoxy resin, hardener and calcium carbonate is used. Polystyrene slabs put together with these materials are used as a heterogeneous phantom. Dose measurements are performed with Gafchromic EBT2 film by using photon beams from the 6-MV CyberKnife at the Seoul Uridul Hospital. The cone sizes of the photon beams are varied from 5 to 10 to 30 mm. When the Balsa wood is inserted in the phantom, the dose measured with EBT2 film is found to be significantly different from the dose without the EBT2 film in and the dose beyond the Balsa wood region, particularly for small field sizes. On the other hand, when the soft bone equivalent material is inserted in the phantom, the discrepancy between the dose measured with EBT2 film and the dose without EBT2 film can be seen only in the region of the soft bone equivalent material. GEANT4 simulations are done with and without the EBT2 film to compare the simulation results with measurements. The GEANT4 simulations including EBT2 film are found to agree well with the measurements for all the cases within an error of 2.2%. The results of the present study show that GEANT4 gives reasonable results for the PDD calculations in heterogeneous media when using photon beams produced by the 6-MV CyberKnife.
引用
收藏
页码:1308 / 1316
页数:9
相关论文
共 50 条
[1]   Image-guided robotic radiosurgery [J].
Adler, JR ;
Murphy, MJ ;
Chang, SD ;
Hancock, SL .
NEUROSURGERY, 1999, 44 (06) :1299-1306
[2]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[3]  
ANDERSEN HH, 1977, STOPPING RANGES IONS, V3
[4]  
[Anonymous], ARXIV14098511
[5]   GEANT4 Simulation of the Shielding of Neutrons from 252Cf Source [J].
Bak, S. I. ;
Park, T. -S. ;
Hong, S. W. ;
Shin, J. W. ;
Hahn, I. S. .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) :2071-2074
[6]   CLINICAL DOSIMETRY FOR IMPLEMENTATION OF A MULTILEAF COLLIMATOR [J].
BOYER, AL ;
OCHRAN, TG ;
NYERICK, CE ;
WALDRON, TJ ;
HUNTZINGER, CJ .
MEDICAL PHYSICS, 1992, 19 (05) :1255-1261
[8]   Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics [J].
Carrier, JF ;
Archambault, L ;
Beaulieu, L ;
Roy, R .
MEDICAL PHYSICS, 2004, 31 (03) :484-492
[9]   Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies [J].
Chiu-Tsao, ST ;
Ho, Y ;
Shankar, R ;
Wang, L ;
Harrison, LB .
MEDICAL PHYSICS, 2005, 32 (11) :3350-3354
[10]  
Cullen D.E., 1997, UCRL 50400, V6, P1997