Use of microchip electrophoresis and a palladium/mercury amalgam electrode for the separation and detection of thiols

被引:12
作者
Antwi, Christiana [1 ]
Johnson, Alicia S. [1 ]
Selimovic, Asmira [1 ]
Martin, R. Scott [1 ]
机构
[1] St Louis Univ, Dept Chem, St Louis, MO 63110 USA
基金
美国国家卫生研究院;
关键词
CAPILLARY-ELECTROPHORESIS; AMPEROMETRIC DETECTION; DUAL-ELECTRODE; INTEGRATION; DECOUPLER; CHROMATOGRAPHY; HOMOCYSTEINE; ERYTHROCYTE; GLUTATHIONE; RELEASE;
D O I
10.1039/c1ay05055a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the use of microchip electrophoresis, a palladium decoupler, and a downstream mercury/palladium (Hg/Pd) amalgam working electrode to separate and detect a mixture of thiols. While it is known that palladium forms an amalgam with mercury that enables the selective detection of thiols at a low potential, previous reports have used mercury/gold (Hg/Au) amalgam electrodes and there are no reports of using Hg/Pd electrodes for this purpose. The ability to use a Hg/Pd electrode greatly simplifies the fabrication procedure when a Pd decoupler is used to integrate microchip electrophoresis with electrochemical detection. A detailed comparison was made between the use of Hg/Au and Hg/Pd detection electrodes, with the Hg/Pd electrode having a similar performance in terms of voltammetry, sensitivity, and limit of detection. The resulting palladium decoupler and Hg/Pd electrode were used along with a lengthened serpentine channel to result in the separation and detection of a mixture containing homocysteine, cysteine, glutathione, and N-acetylcysteine. Finally, a microchip device that integrates on-chip pumping and injection valves with the Pd decoupler and Hg/Pd electrode was used to separate and detect glutathione from lysed red blood cells.
引用
收藏
页码:1072 / 1078
页数:7
相关论文
共 41 条
[1]  
Aaseth J, 2000, J TRACE ELEM EXP MED, V13, P105, DOI 10.1002/(SICI)1520-670X(2000)13:1<105::AID-JTRA12>3.0.CO
[2]  
2-B
[3]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[4]   Selective detection of endogenous thiols using microchip-based flow analysis and mercury/gold amalgam microelectrodes [J].
Batz, Nicholas G. ;
Martin, R. Scott .
ANALYST, 2009, 134 (02) :372-379
[5]   Metabolism, not autoxidation, plays a role in α-oxoaldehyde- and reducing sugar-induced erythrocyte GSH depletion:: Relevance for diabetes mellitus [J].
Beard, KM ;
Shangari, N ;
Wu, B ;
O'Brien, PJ .
MOLECULAR AND CELLULAR BIOCHEMISTRY, 2003, 252 (1-2) :331-338
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF PENICILLAMINE IN WHOLE-BLOOD, PLASMA, AND URINE [J].
BERGSTROM, RF ;
KAY, DR ;
WAGNER, JG .
JOURNAL OF CHROMATOGRAPHY, 1981, 222 (03) :445-452
[7]   Integration of on-chip peristaltic pumps and injection valves with microchip electrophoresis and electrochemical detection [J].
Bowen, Amanda L. ;
Martin, R. Scott .
ELECTROPHORESIS, 2010, 31 (15) :2534-2540
[8]   Integration of serpentine channels for microchip electrophoresis with a palladium decoupler and electrochemical detection [J].
Bowen, Amanda L. ;
Martin, R. Scott .
ELECTROPHORESIS, 2009, 30 (19) :3347-3354
[9]   Palladium film decoupler for amperometric detection in electrophoresis chips [J].
Chen, DC ;
Hsu, FL ;
Zhan, DZ ;
Chen, CH .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :758-762
[10]  
COSTAGLIOLA C, 1990, CLIN PHYSIOL BIOCH, V8, P204