Development and evaluation of intermediate frequency magnetic field exposure system for studies of in vitro biological effects

被引:11
作者
Fujita, Atsush
Hirota, Izuo
Kawahara, Yoshinobu
Omori, Hideki
机构
[1] Matsushita Elect Ind Co Ltd, Matsushita Home Appliances Co, Corp Engn Div, Home Appliance & Housing Elect Res Lab, Toyonaka, Osaka 5810823, Japan
[2] Matsushita Elect Ind Co Ltd, Matsushita Home Appliances Co, Household Appliances Business Grp, IH Cooking Equipment Business Unit,Nishi Ku, Kobe, Hyogo, Japan
[3] Tokyo Elect Power Co Ltd, Yokohama, Kanagawa, Japan
关键词
intermediate frequency (IF); International Commission on Non-ionizing Radiation Protection (ICNIRP); induction heating (III) cook top;
D O I
10.1002/bem.20339
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We have developed an intermediate frequency (IF) magnetic field exposure system for in vitro studies. Since there are no previous studies on exposure to heating-frequency magnetic fields generated from an induction heating (IH) cook top, there is a strong need for such an exposure system and for biological studies of IF magnetic fields. This system mainly consists of a magnetic-field-generating coil housed inside an incubator, inside which cultured cells can be exposed to magnetic field. Two systems were prepared to allow the experiment to be conducted in a double-blind manner. The level of the generated magnetic field was set to 532 mu T-rms in the exposure space, 23 kHz, 80 times the value in the International Commission on Non-ionizing Radiation Protection (ICNIRP) guidelines, with a spatial field uniformity better than 3.8%. The waveforms were nearly sinusoidal. It was also confirmed that the parasitic electric field was 157 V/m(rms) and the induced electric field was 1.9 V/m(rms),. The temperature was maintained at 36.5 0.5 degrees C for 2 h. Furthermore, leaked magnetic flux density was 0.7 mu T-rms or lower at extremely low frequency (ELF) and IF in the stopped system when the other system was being operated, and the environmental magnetic flux density was 0.1 mu T-rms or lower at the center of the coils. As a result, it was confirmed that this system could be successfully used to evaluate the biological effects of exposure to IF magnetic fields.
引用
收藏
页码:538 / 545
页数:8
相关论文
共 11 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
[Anonymous], 2005, IEC62233
[3]  
Harland JD, 1997, BIOELECTROMAGNETICS, V18, P555, DOI 10.1002/(SICI)1521-186X(1997)18:8<555::AID-BEM4>3.0.CO
[4]  
2-1
[5]  
International Agency for Research on Cancer (IARC) Working Group on the Evaluation of Carcinogenic Risks to Humans, 2002, IARC MON, V80
[6]  
LEIGEB N, 2006, EVALUATION RELEVANT
[7]   REPRODUCTIVE INTEGRITY OF MAMMALIAN-CELLS EXPOSED TO POWER FREQUENCY ELECTROMAGNETIC-FIELDS [J].
LIVINGSTON, GK ;
WITT, KL ;
GANDHI, OP ;
CHATTERJEE, I ;
ROTI, JLR .
ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 1991, 17 (01) :49-58
[8]   UNIFORM MAGNETIC-FIELD PRODUCED BY 3-SQUARE, 4-SQUARE, AND 5-SQUARE COILS [J].
MERRITT, R ;
PURCELL, C ;
STROINK, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (07) :879-882
[9]  
MISAKIAN M, 1993, BIOELECTROMAGNETICS, P1, DOI 10.1002/bem.2250140703
[10]   In vitro exposure apparatus for ELF magnetic fields [J].
Schuderer, J ;
Oesch, W ;
Felber, N ;
Spät, D ;
Kuster, N .
BIOELECTROMAGNETICS, 2004, 25 (08) :582-591