Modular Multilevel Converter for Low-Voltage Ride-Through Support in AC Networks

被引:5
作者
Franca Bezerra de Souza, Victor Ramon [1 ]
Barros, Luciano Sales [2 ]
Costa, Flavio Bezerra [1 ]
机构
[1] Univ Fed Rio Grande do Norte, Grad Program Elect & Comp Engn, BR-59064720 Natal, RN, Brazil
[2] Univ Fed Paraiba, Comp Syst Dept, BR-58051900 Coronel Joao Pessoa, Brazil
关键词
modular multilevel converter (MMC); fault support; low-voltage ride-through (LVRT); multilevel converters; grid-connected systems; ENERGY;
D O I
10.3390/en14175314
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
New grid-connected systems have imposed additional requirements regarding reliability, power quality, high levels of power processing capacity, and fault support, where power converters have a crucial role in fulfilling these requirements. Overcoming one of these challenges, this paper proposes a new alternative application to improve the low-voltage ride-through (LVRT) support based on the arm impedance employment of the modular multilevel converter (MMC) by attenuating the fault impacts, avoiding overcurrents and overvoltages. This proposal does not require additional hardware or control loops for LVRT support, only using PI controllers. This paper evaluates symmetrical and asymmetrical grid fault impacts on the converter DC side of four converter topologies: two-level voltage source converter topology (2L-VSC), neutral point clamped (NPC), MMC, and 2L-VSC equipped with a DC-chopper, employing the same control structure for the four topologies, highlighting that the MMC contributed better to LVRT improvement under severe grid conditions.
引用
收藏
页数:12
相关论文
共 25 条
[1]  
Abad G., 2016, Power Electronics and Electric Drives for Traction Applications
[2]  
AbuRub H, 2014, POWER ELECTRONICS FOR RENEWABLE ENERGY SYSTEMS, TRANSPORTATION, AND INDUSTRIAL APPLICATIONS, P1, DOI 10.1002/9781118755525
[3]   Use of Stored Energy in PMSG Rotor Inertia for Low-Voltage Ride-Through in Back-to-Back NPC Converter-Based Wind Power Systems [J].
Alepuz, Salvador ;
Calle, Alejandro ;
Busquets-Monge, Sergio ;
Kouro, Samir ;
Wu, Bin .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (05) :1787-1796
[4]  
[Anonymous], 2003, P IEEE BOLOGNA POWER, DOI [DOI 10.1109/PTC.2003.1304266, 10.1109/PTC.2003.1304403, DOI 10.1109/PTC.2003.1304403]
[5]  
Bollen M. H, 2011, INTEGRATION DISTRIBU, V80
[6]   Three-level converter topologies with switch breakdown fault-tolerance capability [J].
Ceballos, Salvador ;
Pou, Josep ;
Robles, Eider ;
Gabiola, Igor ;
Zaragoza, Jordi ;
Villate, Jose Luis ;
Boroyevich, Dushan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (03) :982-995
[7]   Adaptive DC-Link Voltage Control of Two-Stage Photovoltaic Inverter During Low Voltage Ride-Through Operation [J].
Ding, Guangqian ;
Gao, Feng ;
Tian, Hao ;
Ma, Cong ;
Chen, Mengxing ;
He, Guoqing ;
Liu, Yingliang .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (06) :4182-4194
[8]  
Du S., 2017, Modular multilevel converters: Analysis, control, and applications
[9]   A Resilient Framework for Fault-Tolerant Operation of Modular Multilevel Converters [J].
Ghazanfari, Amin ;
Mohamed, Yasser Abdel-Rady I. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (05) :2669-2678
[10]  
Holmes D.Grahame., 2003, IEEE SERIES POWER EN