Initial experience with a PET/computed tomography system using silicon photomultiplier detectors

被引:3
作者
Park, Sonya Youngju [1 ]
Barrato, Lucia [1 ]
Hatami, Negin [1 ]
Davidzon, Guido [1 ]
Gambhir, Sanjiv Sam [2 ,3 ,4 ,5 ]
Iagaru, Andrei [1 ]
机构
[1] Stanford Univ, Med Ctr, Div Nucl Med & Mol Imaging, 300 Pasteur Dr,Room H-2200, Stanford, CA 94305 USA
[2] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Med Ctr, Dept Bioengn, Stanford, CA 94305 USA
[4] Stanford Univ, Med Ctr, Dept Mat Sci, Stanford, CA 94305 USA
[5] Stanford Univ, Med Ctr, Dept Engn, Stanford, CA 94305 USA
关键词
detectors; PET; computed tomography; silicon photomultiplier; time of flight; TIME-OF-FLIGHT; IMAGE QUALITY; PET/CT; PERFORMANCE; IMPROVEMENTS; CANCER;
D O I
10.1097/MNM.0000000000001088
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose A PET/computed tomography (CT) that uses silicon photomultiplier (SiPM) technology was installed at our institution. Here, we report the initial use of the new scanner and evaluate the image quality in comparison to standard PET/CT scanners. Procedures Seventy-two patients were scanned first using standard PET/CT followed immediately by the new PET/CT system. Images from the new PET/CT system were reconstructed using a conventional [non time-of-flight (TOF)] algorithm, TOF alone and TOF in combination with BSREM. Images from standard PET/CT were reconstructed using clinical standard-of-care settings. Three blinded readers randomly reviewed four datasets (standard, non-TOF, TOF alone, TOF+BSREM) per patient for image quality using a five-point Likert scale. SUV measurements for the single most avid lesion on each dataset were also recorded. Results Datasets from the new scanner had higher image quality (P < 0.001) and SUV measurements (P < 0.001) compared with the standard scanners, and scores further improved when TOF and BSREM algorithms were added (mean scores for standard, non-TOF, TOF alone and TOF+BSREM were 3.1, 3.9, 4.3 and 5.0, respectively; mean SUVmax for hottest lesion were 8.8, 10.3, 10.7 and 13.3, respectively). Conclusion The SiPM-based PET/CT system outperforms two standard Bismuth germanium oxide- and Lutetium-yttrium oxyorthosilicate-based scanners in terms of image quality, with further benefits added using TOF and BSREM. This may be beneficial for detecting small lesions and more accurate disease staging.
引用
收藏
页码:1174 / 1178
页数:5
相关论文
共 20 条
  • [1] 18F-FDG silicon photomultiplier PET/CT: A pilot study comparing semi-quantitative measurements with standard PET/CT
    Baratto, Lucia
    Park, Sonya Young
    Hatami, Negin
    Davidzon, Guido
    Srinivas, Shyam
    Gambhir, Sanjiv Sam
    Iagaru, Andrei
    [J]. PLOS ONE, 2017, 12 (06):
  • [2] Physical Performance of the new hybrid PET/CT Discovery-690
    Bettinardi, V.
    Presotto, L.
    Rapisarda, E.
    Picchio, M.
    Gianolli, L.
    Gilardi, M. C.
    [J]. MEDICAL PHYSICS, 2011, 38 (10) : 5394 - 5411
  • [3] Application of PET/CT in the development of novel anticancer drugs
    Boss, David S.
    Olmos, Renato Valdes
    Sinaasappel, Michiel
    Beijnen, Jos H.
    Schellens, Jan H. M.
    [J]. ONCOLOGIST, 2008, 13 (01) : 25 - 38
  • [4] When should we recommend use of dual time-point and delayed time-point imaging techniques in FDG PET?
    Cheng, Gang
    Torigian, Drew A.
    Zhuang, Hongming
    Alavi, Abass
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (05) : 779 - 787
  • [5] Czernin J, 2007, J NUCL MED, V48, p78S
  • [6] Performance measurements for the PET/CT Discovery-600 using NEMA NU 2-2007 standards
    De Ponti, E.
    Morzenti, S.
    Guerra, L.
    Pasquali, C.
    Arosio, M.
    Bettinardi, V.
    Crespi, A.
    Gilardi, M. C.
    Messa, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (02) : 968 - 974
  • [7] Deller T, 2016, J NUCL MED, V57
  • [8] The Digital Silicon Photomultiplier - Principle of Operation and Intrinsic Detector Performance
    Frach, Thomas
    Prescher, Gordian
    Degenhardt, Carsten
    de Gruyter, Rik
    Schmitz, Anja
    Ballizany, Rob
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1959 - 1965
  • [9] Molecular imaging of cancer with positron emission tomography
    Gambhir, SS
    [J]. NATURE REVIEWS CANCER, 2002, 2 (09) : 683 - 693
  • [10] Variations in PET/CT Methodology for Oncologic Imaging at US Academic Medical Centers: An Imaging Response Assessment Team Survey
    Graham, Michael M.
    Badawi, Ramsey D.
    Wahl, Richard L.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (02) : 311 - 317