Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction

被引:10
作者
Laukamp, Kai Roman [1 ,2 ,3 ,4 ]
Hokamp, Nils Grosse [1 ,2 ,3 ,4 ]
Alabar, Omar [1 ,2 ]
Obmann, Verena Carola [1 ,2 ]
Lennartz, Simon [3 ,4 ]
Zopfs, David [3 ,4 ]
Gilkeson, Robert [1 ,2 ]
Ramaiya, Nikhil [1 ,2 ]
Gupta, Amit [1 ,2 ]
机构
[1] Univ Hosp Cleveland, Med Ctr, Dept Radiol, 11000 Euclid Ave, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
[3] Univ Cologne, Fac Med, Inst Diagnost & Intervent Radiol, Cologne, Germany
[4] Univ Cologne, Univ Hosp Cologne, Cologne, Germany
关键词
X-ray computed tomography; Artifacts; Sternal wires; Neoplasm staging; Thoracic surgery; Spectral-detector CT; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; ORTHOPEDIC HARDWARE; RECONSTRUCTION; EXTRAPOLATION; SOFTWARE; IMPLANTS; SPINE;
D O I
10.1016/j.clinimag.2019.12.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In chest imaging, sternal wires can cause metal artifacts that hamper depiction of surrounding soft tissue and bone. This study investigated if these artifacts may be reduced by means of virtual monoenergetic images (VMD obtained from a novel detector-based spectral CT scanner (SDCT) in comparison to conventional CT images (CI). Materials and methods: 30 patients with clinically indicated SDCT scans of the chest exhibiting artifacts due to sternal wires were included in this IRB-approved study. CI and VMI (40-200 keV, 10 keV increment) were reconstructed. Quantitative image analysis was conducted by ROI-based measurement of attenuation (HU) and standard deviation within the most pronounced hypo- and hyperdense artifacts. Visually, artifact reduction and diagnostic assessment of surrounding soft tissue as well as sternal bone were independently rated by two radiologists on 5-point Likert-scales. Results: In comparison to CI, high-keV VMI showed an effective reduction of hypo- and hyperattenuating parasternal artifacts, as corrected HU-values approximated their true expected values (hypodense: CI -66.2 +/- 70.8; VMI200keV 2.4 +/- 29.2; hyperdense: CI 156.7 +/- 70.8HU; VMI200keV 76.9 +/- 45.4, both p < 0.05). In addition, image noise was significantly lower in high-keV VMI compared to Cl. Subjective analysis confirmed that VMI of 100 keV significantly reduced artifacts and improved diagnostic assessment of surrounding soft tissue and bone. Interrater-agreement was excellent (intraclass-correlation-coefficient = 0.83). Conclusions: High-keV VMI yielded a significant reduction of artifacts from sternal wires and improved assessment of surrounding structures.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 39 条
  • [31] Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
    McCollough, Cynthia H.
    Leng, Shuai
    Yu, Lifeng
    Fletcher, Joel G.
    [J]. RADIOLOGY, 2015, 276 (03) : 637 - 653
  • [32] Photon starvation artifacts of X-ray CT: Their true cause and a solution
    Mori I.
    Machida Y.
    Osanai M.
    Iinuma K.
    [J]. Radiological Physics and Technology, 2013, 6 (1) : 130 - 141
  • [33] Metal artifact reduction by dual-layer computed tomography using virtual monoenergetic images
    Neuhaus, Victor
    Hokamp, Nils Grosse
    Abdullayev, Nuran
    Rau, Robert
    Mpotsaris, Anastasios
    Maintz, David
    Borggrefe, Jan
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 143 - 148
  • [34] Role of Dual-Energy Computed Tomography in Thoracic Oncology
    Odisio, Erika G.
    Truong, Mylene T.
    Duran, Cihan
    de Groot, Patricia M.
    Godoy, Myrna C.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 535 - +
  • [35] Comparison of radiation dose and image quality from single-energy and dual-energy CT examinations in the same patients screened for hepatocellular carcinoma
    Purysko, A. S.
    Primak, A. N.
    Baker, M. E.
    Obuchowski, N. A.
    Remer, E. M.
    John, B.
    Herts, B. R.
    [J]. CLINICAL RADIOLOGY, 2014, 69 (12) : E538 - E544
  • [36] Monoenergetic extrapolation of cardiac dual energy CT for artifact reduction
    Secchi, Francesco
    De Cecco, Carlo Nicola
    Spearman, James Vance
    Silverman, Justin Robert
    Ebersberger, Ullrich
    Sardanelli, Francesco
    Schoepf, U. Joseph
    [J]. ACTA RADIOLOGICA, 2015, 56 (04) : 413 - 418
  • [37] Metal artifact reduction techniques in musculoskeletal CT-imaging
    Wellenberg, R. H. H.
    Hakvoort, E. T.
    Slump, C. H.
    Boomsma, M. F.
    Maas, M.
    Streekstra, G. J.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 107 : 60 - 69
  • [38] Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses
    Wellenberg, R. H. H.
    Boomsma, M. F.
    van Osch, J. A. C.
    Vlassenbroek, A.
    Milles, J.
    Edens, M. A.
    Streekstra, G. J.
    Slump, C. H.
    Maas, M.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 88 : 61 - 70
  • [39] Metal Artifact Reduction From Reformatted Projections for Hip Prostheses in Multislice Helical Computed Tomography Techniques and Initial Clinical Results
    Yu, Lifeng
    Li, Hua
    Mueller, Jan
    Kofler, James M.
    Liu, Xin
    Primak, Andrew N.
    Fletcher, Joel G.
    Guimaraes, Luis S.
    Macedo, Thanila
    McCollough, Cynthia H.
    [J]. INVESTIGATIVE RADIOLOGY, 2009, 44 (11) : 691 - 696