Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction

被引:10
作者
Laukamp, Kai Roman [1 ,2 ,3 ,4 ]
Hokamp, Nils Grosse [1 ,2 ,3 ,4 ]
Alabar, Omar [1 ,2 ]
Obmann, Verena Carola [1 ,2 ]
Lennartz, Simon [3 ,4 ]
Zopfs, David [3 ,4 ]
Gilkeson, Robert [1 ,2 ]
Ramaiya, Nikhil [1 ,2 ]
Gupta, Amit [1 ,2 ]
机构
[1] Univ Hosp Cleveland, Med Ctr, Dept Radiol, 11000 Euclid Ave, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
[3] Univ Cologne, Fac Med, Inst Diagnost & Intervent Radiol, Cologne, Germany
[4] Univ Cologne, Univ Hosp Cologne, Cologne, Germany
关键词
X-ray computed tomography; Artifacts; Sternal wires; Neoplasm staging; Thoracic surgery; Spectral-detector CT; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; ORTHOPEDIC HARDWARE; RECONSTRUCTION; EXTRAPOLATION; SOFTWARE; IMPLANTS; SPINE;
D O I
10.1016/j.clinimag.2019.12.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In chest imaging, sternal wires can cause metal artifacts that hamper depiction of surrounding soft tissue and bone. This study investigated if these artifacts may be reduced by means of virtual monoenergetic images (VMD obtained from a novel detector-based spectral CT scanner (SDCT) in comparison to conventional CT images (CI). Materials and methods: 30 patients with clinically indicated SDCT scans of the chest exhibiting artifacts due to sternal wires were included in this IRB-approved study. CI and VMI (40-200 keV, 10 keV increment) were reconstructed. Quantitative image analysis was conducted by ROI-based measurement of attenuation (HU) and standard deviation within the most pronounced hypo- and hyperdense artifacts. Visually, artifact reduction and diagnostic assessment of surrounding soft tissue as well as sternal bone were independently rated by two radiologists on 5-point Likert-scales. Results: In comparison to CI, high-keV VMI showed an effective reduction of hypo- and hyperattenuating parasternal artifacts, as corrected HU-values approximated their true expected values (hypodense: CI -66.2 +/- 70.8; VMI200keV 2.4 +/- 29.2; hyperdense: CI 156.7 +/- 70.8HU; VMI200keV 76.9 +/- 45.4, both p < 0.05). In addition, image noise was significantly lower in high-keV VMI compared to Cl. Subjective analysis confirmed that VMI of 100 keV significantly reduced artifacts and improved diagnostic assessment of surrounding soft tissue and bone. Interrater-agreement was excellent (intraclass-correlation-coefficient = 0.83). Conclusions: High-keV VMI yielded a significant reduction of artifacts from sternal wires and improved assessment of surrounding structures.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 39 条
  • [1] Iterative metal artefact reduction in CT: can dedicated algorithms improve image quality after spinal instrumentation?
    Aissa, J.
    Thomas, C.
    Sawicki, L. M.
    Caspers, J.
    Kroepil, P.
    Antoch, G.
    Boos, J.
    [J]. CLINICAL RADIOLOGY, 2017, 72 (05) : 428.e7 - 428.e12
  • [2] Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen
    Albrecht, Moritz H.
    Trommer, Jesko
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Martin, Simon S.
    Lehnert, Thomas
    Vogl, Thomas J.
    Bodelle, Boris
    [J]. INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 582 - 590
  • [3] ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY
    ALVAREZ, RE
    MACOVSKI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) : 733 - 744
  • [4] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [5] High Prevalence of Pseudotumors in Patients with a Birmingham Hip Resurfacing Prosthesis A Prospective Cohort Study of One Hundred and Twenty-nine Patients
    Bisschop, R.
    Boomsma, M. F.
    Van Raay, J. J. A. M.
    Tiebosch, A. T. M. G.
    Maas, M.
    Gerritsma, C. L. E.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (17) : 1554 - 1560
  • [6] Boas FE., 2012, Imaging Med, V4, P229, DOI [10.2217/iim.12.13, DOI 10.2217/IIM.12.13]
  • [7] Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study
    Boomsma, Martijn F.
    Warringa, Niek
    Edens, Mireille A.
    Mueller, Dirk
    Ettema, Harmen B.
    Verheyen, Cees C. P. M.
    Maas, Mario
    [J]. SPRINGERPLUS, 2016, 5
  • [8] Dual-energy CT with virtual monochromatic images and metal artifact reduction software for reducing metallic dental artifacts
    Cha, Jihoon
    Kim, Hyung-Jin
    Kim, Sung Tae
    Kim, Yi Kyung
    Kim, Ha Youn
    Park, Gyeong Min
    [J]. ACTA RADIOLOGICA, 2017, 58 (11) : 1312 - 1319
  • [9] A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) : 37 - 46
  • [10] Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?
    De Crop, An
    Casselman, Jan
    Van Hoof, Tom
    Dierens, Melissa
    Vereecke, Elke
    Bossu, Nicolas
    Pamplona, Jaime
    D'Herde, Katharina
    Thierens, Hubert
    Bacher, Klaus
    [J]. NEURORADIOLOGY, 2015, 57 (08) : 841 - 849