DOSE REDUCTION AND IMAGE QUALITY ASSESSMENT IN MDCT USING AEC (D-DOM & Z-DOM) AND IN-PLANE BISMUTH SHIELDING

被引:14
作者
Lee, Kibaek [1 ]
Lee, Wonho [1 ]
Lee, Junhyup [2 ,3 ]
Lee, Boram [1 ]
Oh, Gyubum [1 ]
机构
[1] Korea Univ, Dept Radiol Sci, Seoul, South Korea
[2] Korea Univ, Anam Hosp, Dept Radiol, Seoul, South Korea
[3] Korea Univ, Anam Hosp, Ctr Imaging Sci, Seoul, South Korea
关键词
BREAST; CT;
D O I
10.1093/rpd/ncq159
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Since computed tomography (CT) was introduced about 40 y ago, its use has continuously grown, resulting in the increase of the CT dose. Therefore, an awareness of the CT dose and its potential complications has led to the development of several dose reduction strategies. One of the strategies is automatic exposure control (AEC), which modulates radiation intensity depending on the patient size, z-axis thickness (Z-DOM) or angular thickness (D-DOM). Another dose reduction method is the in-plane bismuth shield which attenuates radiation to reduce the CT doses of the tissues underneath the shield. We evaluated and compared the dose reduction and image quality of CT for various dose reduction techniques. The result showed that both AEC and the in-plane shield reduced the CT dose effectively and the combined method of AEC and in-plane shielding reduced the CT dose more than the single use of AEC or in-plane shields. The dose reduction using Z-DOM was normally higher than that using D-DOM. The image quality of CT dramatically degraded when the in-plane shield was directly attached to the phantom without using AEC. In order to effectively reduce CT dose without the significant degradation of the image quality, the in-plane shield should be placed 1 cm apart from the patient with applying AEC control.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 12 条
  • [1] *CAN I HLTH INF, 2005, MED IM CAN 2005, P5
  • [2] CATUZZO P, 2010, MED PHYS, V115, P152
  • [3] CHANG KH, 2009, RADIAT PROT DOSIM, P1
  • [4] In-plane bismuth breast shields for pediatric CT: Effects on radiation dose and image quality using experimental and clinical data
    Fricke, BL
    Donnelly, LF
    Frush, DP
    Yoshizumi, T
    Varchena, V
    Poe, SA
    Lucaya, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) : 407 - 411
  • [5] Hawking Nancy, 2009, Radiol Technol, V80, P411
  • [6] Radiation dose reduction to breast and thyroid during MDCT:: Effectiveness of an in-plane bismuth shield
    Hohl, C
    Wildberger, JE
    Süss, C
    Thomas, C
    Mühlenbruch, G
    Schmidt, T
    Honnef, D
    Günther, RW
    Mahnken, AH
    [J]. ACTA RADIOLOGICA, 2006, 47 (06) : 562 - 567
  • [7] International Commission on Radiological Protection, 2007, ANN ICRP, V103
  • [8] KACHELRIESS M, 2006, STRATEGIES DOSE REDU, P35
  • [9] KALRA MK, 2007, AUTOMATIC EXPOSURE C, P117
  • [10] Strategies for Reducing Radiation Dose in CT
    McCollough, Cynthia H.
    Primak, Andrew N.
    Braun, Natalie
    Kofler, James
    Yu, Lifeng
    Christner, Jodie
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) : 27 - +