The impact of ultra-high-density mapping on long-term outcome after catheter ablation of ventricular tachycardia

被引:1
|
作者
Schleberger, Ruben [1 ,3 ]
Schwarzl, Jana M. [1 ]
Moser, Julia [1 ]
Nies, Moritz [1 ]
Hoeller, Alexandra [2 ]
Muenkler, Paula [1 ,3 ]
Dinshaw, Leon [1 ]
Jungen, Christiane [1 ,3 ,4 ]
Lemoine, Marc D. [1 ]
Maury, Philippe [5 ]
Sacher, Frederic [6 ]
Martin, Claire A. [7 ]
Wong, Tom [8 ]
Estner, Heidi L. [9 ]
Jais, Pierre [6 ]
Willems, Stephan [3 ,10 ]
Eickholt, Christian [10 ]
Meyer, Christian [3 ,11 ,12 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Inst Med Biometry & Epidemiol, Ctr Med Expt, Hamburg, Germany
[3] DZHK German Ctr Cardiovasc Res, Partner Site Hamburg Kiel Lubeck, Berlin, Germany
[4] Leiden Univ, Dept Cardiol, Willem Einthoven Ctr Cardiac Arrhythmia Res & Man, Med Ctr, Leiden, Netherlands
[5] Univ Hosp Rangueil, Dept Cardiol, Toulouse, France
[6] Univ Bordeaux, LIRYC Inst, CHU Bordeaux, Bordeaux, France
[7] Natl Hlth Serv Fdn Trust, Royal Papworth Hosp, Cambridge, England
[8] Imperial Coll London, Royal Brompton & Harefield NHS Fdn Trust, Heart Rhythm Ctr, London, England
[9] Ludwig Maximilian Univ Munich, Univ Hosp Munich, Dept Internal Med Cardiol 1, Munich, Germany
[10] Asklepios Hosp St Georg, Dept Cardiol, Hamburg, Germany
[11] EVK Dusseldorf, Dept Cardiol, Cardiac Neuro & Elect Res Consortium cNEP, Dusseldorf, Germany
[12] Heinrich Heine Univ Dusseldorf, Fac Med, Cardiac Neuro & Elect Res Consortium cNEP, Dusseldorf, Germany
关键词
SUBSTRATE ABLATION; END-POINT; SCAR; SYSTEM;
D O I
10.1038/s41598-022-12918-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ultra-high-density (UHD) mapping can improve scar area detection and fast activation mapping in patients undergoing catheter ablation of ventricular tachycardia (VT). The aim of the present study was to compare the outcome after VT ablation guided by UHD and conventional point-by-point 3D-mapping. The acute and long-term ablation outcome of 61 consecutive patients with UHD mapping (64-electrode mini-basket catheter) was compared to 61 consecutive patients with conventional point-by-point 3D-mapping using a 3.5 mm tip catheter. Patients, whose ablation was guided by UHD mapping had an improved 24-months outcome in comparison to patients with conventional mapping (cumulative incidence estimate of the combination of recurrence or disease-related death of 52.4% (95% confidence interval (CI) [36.9-65.7]; recurrence: n = 25; disease-related death: n = 4) versus 69.6% (95% CI [55.9-79.8]); recurrence: n = 31; disease-related death n = 11). In a cause-specific Cox proportional hazards model, UHD mapping (hazard ratio (HR) 0.623; 95% CI [0.390-0.995]; P = 0.048) and left ventricular ejection fraction > 30% (HR 0.485; 95% CI [0.290-0.813]; P = 0.006) were independently associated with lower rates of recurrence or disease-related death. Other procedural parameters were similar in both groups. In conclusion, UHD mapping during VT ablation was associated with fewer VT recurrences or disease-related deaths during long-term follow-up in comparison to conventional point-by-point mapping. Complication rates and other procedural parameters were similar in both groups.
引用
收藏
页数:9
相关论文
共 41 条
  • [21] Utility of high density multielectrode mapping during ablation of scar-related ventricular tachycardia
    Cano, Oscar
    Plaza, Diego
    Sauri, Assumpcio
    Osca, Joaquin
    Alonso, Pau
    Andres, Ana
    Sancho-Tello, Maria-Jose
    Martinez-Dolz, Luis
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (11) : 1306 - 1315
  • [22] Comparison between Standard and High-Definition Multi-Electrode Mapping Catheter in Ventricular Tachycardia Ablation
    Conti, Sergio
    Sabatino, Francesco
    De Blasi, Gabriele
    Di Stabile, Giuseppe
    Sgarito, Giuseppe
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (08)
  • [23] Epicardial ventricular tachycardia in ischemic cardiomyopathy: Prevalence, electrophysiological characteristics, and long-term ablation outcomes
    Hayashi, Tatsuya
    Liang, Jackson J.
    Muser, Daniele
    Shirai, Yasuhiro
    Enriquez, Andres
    Garcia, Fermin C.
    Supple, Gregory E.
    Schaller, Robert D.
    Frankel, David S.
    Lin, David
    Nazarian, Saman
    Zado, Erica S.
    Arkles, Jeffrey S.
    Dixit, Sanjay
    Callans, David J.
    Marchlinski, Francis E.
    Santangeli, Pasquale
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) : 1530 - 1539
  • [24] Enhanced ventricular tachycardia substrate resolution with a novel omnipolar high-density mapping catheter: the omnimapping study
    Riccardo Proietti
    Ahmed M. Adlan
    Rory Dowd
    Shershah Assadullah
    Bashar Aldhoon
    Sandeep Panikker
    Will Foster
    Shamil Yusuf
    Sajad Hayat
    Faizel Osman
    Prithwish Banerjee
    Tarvinder Dhanjal
    Journal of Interventional Cardiac Electrophysiology, 2020, 58 : 355 - 362
  • [25] Long-Term Outcomes of Combined Epicardial and Endocardial Ablation of Monomorphic Ventricular Tachycardia Related to Hypertrophic Cardiomyopathy
    Dukkipati, Srinivas R.
    d'Avila, Andre
    Soejima, Kyoko
    Bala, Rupa
    Inada, Keiichi
    Singh, Sheldon
    Stevenson, William G.
    Marchlinski, Francis E.
    Reddy, Vivek Y.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (02) : 185 - U113
  • [26] Long-term results and the predictors of outcome of catheter ablation of atrial fibrillation using steerable sheath catheter navigation after single procedure in 674 patients
    Arya, Arash
    Hindricks, Gerhard
    Sommer, Philipp
    Huo, Yan
    Bollmann, Andreas
    Gaspar, Thomas
    Bode, Kerstin
    Husser, Daniela
    Kottkamp, Hans
    Piorkowski, Christopher
    EUROPACE, 2010, 12 (02): : 173 - 180
  • [27] Orthogonal high-density mapping with ventricular tachycardia isthmus analysis vs. pure substrate ventricular tachycardia ablation: A case-control study
    Vazquez-Calvo, Sara
    Garre, Paz
    Sanchez-Somonte, Paula
    Borras, Roger
    Quinto, Levio
    Caixal, Gala
    Pujol-Lopez, Margarida
    Althoff, Till
    Guasch, Eduard
    Arbelo, Elena
    Tolosana, Jose Maria
    Brugada, Josep
    Mont, Lluis
    Roca-Luque, Ivo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [28] Safety, Long-Term Results, and Predictors of Recurrence After Complete Endocardial Ventricular Tachycardia Substrate Ablation in Patients With Previous Myocardial Infarction
    Arenal, Angel
    Hernandez, Jesuts
    Calvo, David
    Ceballos, Cecilia
    Atea, Leonardo
    Datino, Tomas
    Atienza, Felipe
    Gonzalez-Torrecilla, Esteban
    Eidelman, Gabriel
    Miracle, Angel
    Avila, Pablo
    Bermejo, Javier
    Fernandez-Aviles, Francisco
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (04) : 499 - 505
  • [29] High-density substrate-guided ventricular tachycardia ablation: Role of activation mapping in an attempt to improve procedural effectiveness
    Carbucicchio, Corrado
    Raja, Nadeem Ahmad
    Di Biase, Luigi
    Volpe, Valeria
    Dello Russo, Antonio
    Trivedi, Chintan
    Bartoletti, Stefano
    Zucchetti, Martina
    Casella, Michela
    Russo, Eleonora
    Santangeli, Pasquale
    Moltrasio, Massimo
    Tundo, Fabrizio
    Fassini, Gaetano
    Natale, Andrea
    Tondo, Claudio
    HEART RHYTHM, 2013, 10 (12) : 1850 - 1858
  • [30] Catheter ablation of atrial fibrillation with box isolation of fibrotic areas: Lessons on fibrosis distribution and extent, clinical characteristics, and their impact on long-term outcome
    Schreiber, Doreen
    Rieger, Andreas
    Moser, Fabian
    Kottkamp, Hans
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (09) : 971 - 983