Current devices used for the monitoring of injection pressure during peripheral nerve blocks

被引:6
|
作者
Gadsden, Jeff [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Anesthesiol, Durham, NC 27710 USA
关键词
Nerve block; monitoring; injection pressure; nerve injury; complication; regional anesthesia; patient safety; REGIONAL ANESTHESIA; INTRANEURAL INJECTION; LOCAL-ANESTHETICS; NEEDLE-NERVE; INJURY; COMPLICATIONS; CONTACT; SPACE; MODEL; LEADS;
D O I
10.1080/17434440.2018.1507731
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Peripheral nerve blocks are generally safe. However, there is a small but real associated risk of needle-related complications such as nerve injury. Nerve injury has been associated with high pressure injections in animals, and some data supports the use of monitors to limit injection pressure during these procedures.Areas covered: A literature search for articles with keywords injection,' pressure,' and nerve' was conducted. All currently available devices designed to monitor injection pressure and/or prevent high pressure injections were reviewed. There are three classes of devices that are used to monitor injection pressure. The first is based on Boyle's Law, and involves the clinician limiting the compression of a known quantity of air in the syringe, thereby preventing a corresponding increase in pressure. The second is the use of electronic pressure manometers present in syringe pumps. Finally, two specialized in-line devices, the BSmart and the NerveGuard, serve to warn of, or prevent, respectively, injection at high pressures.Expert commentary: While each of the reviewed methods has its advantages and drawbacks, all of the means of injection pressure monitoring are relatively simple and inexpensive to perform. More outcomes data are required to demonstrate a reduction in injury with their use.
引用
收藏
页码:571 / 578
页数:8
相关论文
共 50 条
  • [31] Intraneural Injection with Low-Current Stimulation During Popliteal Sciatic Nerve Block
    Robards, Christopher
    Hadzic, Admir
    Somasundaram, Lakshmanasamy
    Iwata, Takashige
    Gadsden, Jeff
    Xu, Daquan
    Sala-Blanch, Xavier
    ANESTHESIA AND ANALGESIA, 2009, 109 (02) : 673 - 677
  • [32] Pressure monitoring devices may undetect epidural space: a report on the use of Compuflo® system for epidural injection
    Massimiliano Carassiti
    Giuseppe Pascarella
    Alessandro Strumia
    Rita Cataldo
    Vincenzo Antinolfi
    Fabio Costa
    Felice Eugenio Agrò
    Journal of Clinical Monitoring and Computing, 2022, 36 : 283 - 286
  • [33] Pressure monitoring devices may undetect epidural space: a report on the use of Compuflo® system for epidural injection
    Carassiti, Massimiliano
    Pascarella, Giuseppe
    Strumia, Alessandro
    Cataldo, Rita
    Antinolfi, Vincenzo
    Costa, Fabio
    Agro, Felice Eugenio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (01) : 283 - 286
  • [34] Impact of varying degrees of peripheral nerve blockade on experimental pressure and ischemic pain: adductor canal and sciatic nerve blocks in a human model of compartment syndrome pain
    Chen, Yun-Yun Kathy
    Lirk, Philipp
    Flowers, K. Mikayla
    Colebaugh, Carin A.
    Wilson, Jenna M.
    Zeballos, Jose
    Von Keudell, Arvind
    Barrett, Karyn E.
    Vlassakov, Kamen
    Schreiber, Kristin L.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2022, 47 (10) : 630 - 636
  • [35] Anesthesia via peripheral nerve blocks during total knee replacement has no effect on postoperative inflammation in elderly patients
    Lu, Bin
    Jin, Jianwen
    Pei, Shujun
    Gong, Maowei
    Liu, Junle
    JOURNAL OF ORTHOPAEDIC SURGERY, 2023, 31 (03)
  • [36] Monitoring peripheral nerve function during external fixation of upper extremities
    Makarov, MR
    Delgado, MR
    Birch, JG
    Samchukov, ML
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (05) : 663 - 667
  • [37] PERIPHERAL-NERVE INJURY CAUSED BY INJECTION NEEDLES USED IN REGIONAL ANESTHESIA - INFLUENCE OF BEVEL CONFIGURATION, STUDIED IN A RAT MODEL
    RICE, ASC
    MCMAHON, SB
    BRITISH JOURNAL OF ANAESTHESIA, 1992, 69 (05) : 433 - 438
  • [38] High Opening Injection Pressure Is Associated With Needle-Nerve and Needle-Fascia Contact During Femoral Nerve Block
    Gadsden, Jeff
    Latmore, Malikah
    Levine, D. Matt
    Robinson, Allegra
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2016, 41 (01) : 50 - 55
  • [39] Utility of intraoperative monitoring with motor-evoked potential during the surgical enucleation of peripheral nerve schwannoma
    Sasaki, Hiromi
    Nagano, Satoshi
    Yokouchi, Masahiro
    Setoguchi, Takao
    Shimada, Hirofumi
    Yamamoto, Takuya
    Ishidou, Yasuhiro
    Komiya, Setsuro
    ONCOLOGY LETTERS, 2018, 15 (06) : 9327 - 9332
  • [40] Ultrasound provides a reliable test of local anaesthetic spread during performance of peripheral nerve blocks
    McCartney, C. J. L.
    Dickinson, V.
    Dubrowski, A.
    Riazi, S.
    McHardy, P.
    Awad, I.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (04) : 583 - 583