Performance investigation on the liquid desiccant regeneration using rotating packed bed

被引:7
|
作者
Gu, Yangyang [1 ]
Zhang, Xiaosong [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid desiccant; Regeneration; Rotating packed bed; Heat and mass transfer; MASS-TRANSFER PERFORMANCE; WASTE-WATER TREATMENT; HIGH GRAVITY; CO2; CAPTURE; AIR DEHUMIDIFICATION; TRANSFER MODEL; HEAT; ABSORPTION; SYSTEM; TOWER;
D O I
10.1016/j.ijrefrig.2019.09.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
The regenerator which is applied to recover the dilute solution plays a significant role in the liquid desiccant system. Rotating packed bed (RPB) has been demonstrated to heat and mass transfer process intensification, and successfully applied in the field of gas absorption. To validate the application of rotating packed bed in the regeneration of the dilute solution, a counter-flow RPB regenerator was studied in this work. Three groups of performance indices including moisture removal rate, heat and mass transfer coefficients, and regeneration effectiveness, were employed to evaluate the performance of the regenerator. The effects of the high gravity factor, air flux, solution flux, air inlet parameters, and solution inlet parameters on the performance indices were investigated and compared with the conventional regenerator. Correlations of heat and mass transfer coefficients were presented on the basis of the experimental data. The mass transfer coefficients of RPB regenerator locate within 12.5-35.6 kg m(-3) s(-1) which are higher than those in the conventional regenerators. According to the comparison, the RPB regenerator has superiority in the mass transfer performances. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
  • [1] Quick performance prediction of liquid desiccant regeneration in a packed bed
    Gandhidasan, P
    SOLAR ENERGY, 2005, 79 (01) : 47 - 55
  • [2] Numerical and experimental study on the regeneration performance of a liquid desiccant system coupled with rotating packed bed and vacuum
    Li, Hongxuan
    Zou, Tonghua
    Han, Xiaowan
    Dai, Baomin
    Liu, Jia
    APPLIED ENERGY, 2023, 336
  • [3] Effect of regeneration mode on the performance of liquid desiccant packed bed regenerator
    Liu, X. H.
    Jiang, Y.
    Yi, X. Q.
    RENEWABLE ENERGY, 2009, 34 (01) : 209 - 216
  • [4] Performance study on the dehumidifier of a packed bed liquid desiccant system
    Salarian, H.
    Ghorbani, B.
    Amidpour, Majid
    Salehi, G.
    SCIENTIA IRANICA, 2014, 21 (01) : 222 - 228
  • [5] Handling zone dividing method in packed bed liquid desiccant dehumidification/regeneration process
    Liu, X. H.
    Jiang, Y.
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (12) : 3024 - 3034
  • [6] Heat and mass transfer in packed bed liquid desiccant regenerators - An experimental investigation
    Martin, V
    Goswami, DY
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (03): : 162 - 170
  • [7] Experimental Investigation on Thermal Performance Characteristics of Rotating Packed Bed
    Kumar, Sandeep
    Kumar, Gaurav
    Murthy, D. S.
    EXPERIMENTAL HEAT TRANSFER, 2023, 36 (03) : 331 - 343
  • [8] Performance investigation on the ultrasonic atomization liquid desiccant regeneration system
    Yang, Zili
    Zhang, Kaisheng
    Hwang, Yunho
    Lian, Zhiwei
    APPLIED ENERGY, 2016, 171 : 12 - 25
  • [9] Initial liquid dispersion and mass transfer performance in a rotating packed bed
    Lu, Yan-Zhen
    Liu, Wei
    Xu, Ying-Chun
    Luo, Yong
    Chu, Guang-Wen
    Chen, Jian-Feng
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2019, 140 : 136 - 141
  • [10] Performance analysis of dehumidification rotating wheel using liquid desiccant
    Hamed, AM
    Khalil, A
    Kabeel, AE
    Bassuoni, MM
    Elzahaby, AM
    RENEWABLE ENERGY, 2005, 30 (11) : 1689 - 1712