摘要
A techno-economic analysis was carried out to assess the oxy-fuel conversion of eight major coal-fired power plants in the state of NSW, Australia. For this purpose, several alternative retrofit configurations, differing only in the air separation unit (ASU) but otherwise identical, were considered. More specifically, three types of oxygen plants were studied: a cryogenic-based air separation unit and integrated chemical looping air separation units using steam (ICLAS[S]) and recycled flue gas (ICLAS[FG]) as the reduction medium. The main objective of the techno-economic analysis was to determine if the economic viability of oxy-fuel operations could be enhanced by incorporating ICLAS technology. The results show that the normalized oxygen demand for the NSW fleet of coal-fired power plants was about 450550 m(3)/MWh, with Bayswater having the lowest normalized oxygen demand and Munmorah having the highest one. Moreover, it was found that by replacing a cryogenic-based ASU with an ICLAS unit, the average reduction in the ASU power demand was up to 47% and 76%, respectively, for ICLAS[S] and ICLAS[FG]. Similarly, the average thermal efficiency penalty associated with the cryogenic and the ICLAS[S] and ICLAS[FG] units was found to be about 9.5%, 7.5%, and 5%, respectively, indicating that the ICLAS[FG] unit is the most energy efficient option for oxy-fuel plants. Economic analyses suggest that a retrofit cost reduction of about 32% can be achieved by incorporating an ICLAS[FG] unit. On average, the levelized cost of electricity associated with the cryogenic and the ICLAS[S] and ICLAS[FG] units for the NSW fleet of coal-fired power plants was found to be about $118/MWh, $105/MWh, and $95/MWh, respectively.
引用
收藏
页码:2074 / 2088
页数:15
相关论文
共 50 条
  • [41] Energy audit, techno-economic, and environmental assessment of integrating solar technologies for energy management in a university residential building: A case study
    Bosu, Issa
    Mahmoud, Hatem
    Hassan, Hamdy
    APPLIED ENERGY, 2023, 341
  • [42] Techno-economic assessment of high-temperature aquifer thermal energy storage system, insights from a study case in Burgwedel, Germany
    Zhou, Dejian
    Li, Ke
    Gao, Huhao
    Tatomir, Alexandru
    Sauter, Martin
    Ganzer, Leonhard
    APPLIED ENERGY, 2024, 372
  • [43] Techno-Economic Assessment of Combined Heat and Power Units Fuelled by Waste Vegetable Oil for Wastewater Treatment Plants: A Real Case Study
    Di Fraia, Simona
    Massarotti, Nicola
    Vanoli, Laura
    Bentivoglio, Riccardo
    Milani, Gianfranco
    FRONTIERS IN WATER-ENERGY-NEXUS NATURE-BASED SOLUTIONS, ADVANCED TECHNOLOGIES AND BEST PRACTICES FOR ENVIRONMENTAL SUSTAINABILITY, 2020, : 345 - 348
  • [44] Techno-economic assessment of soiling losses in CSP and PV solar power plants: A case study for the semi-arid climate of Morocco
    Abraim, Mounir
    Salihi, Mustapha
    El Alani, Omaima
    Hanrieder, Natalie
    Ghennioui, Hicham
    Ghennioui, Abdellatif
    El Ydrissi, Massaab
    Azouzoute, Alae
    ENERGY CONVERSION AND MANAGEMENT, 2022, 270
  • [45] Exogenous-spatial scale techno-economic methodology for energy application assessment based on levelized cost of electricity: A case study in Norway
    Weerakoon, A. H. Samitha
    Kleszcz, Slawosz
    Assadi, Mohsen
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 22
  • [46] Techno-Economic Assessment of Molten Salt-Based Concentrated Solar Power: Case Study of Linear Fresnel Reflector with a Fossil Fuel Backup under Saudi Arabia's Climate Conditions
    Aljudaya, Ahmed
    Michailos, Stavros
    Ingham, Derek B.
    Hughes, Kevin J.
    Ma, Lin
    Pourkashanian, Mohamed
    ENERGIES, 2024, 17 (11)
  • [47] Check updates Original Optimization and techno-economic assessment of concentrated solar power (CSP) in South-Western Africa: A case study on Ghana
    Agyekum, Ephraim Bonah
    Velkin, Vladimir Ivanovich
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 40 (40)
  • [48] Simulation of a 100-MW solar-powered thermo-chemical air separation system combined with an oxy-fuel power plant for bio-energy with carbon capture and storage (BECCS)
    Patzschke, Clemens F.
    Bahzad, Husain
    Boot-Handford, Matthew E.
    Fennell, Paul S.
    MITIGATION AND ADAPTATION STRATEGIES FOR GLOBAL CHANGE, 2020, 25 (04) : 539 - 557
  • [49] Simulation of a 100-MW solar-powered thermo-chemical air separation system combined with an oxy-fuel power plant for bio-energy with carbon capture and storage (BECCS)
    Clemens F. Patzschke
    Husain Bahzad
    Matthew E. Boot-Handford
    Paul S. Fennell
    Mitigation and Adaptation Strategies for Global Change, 2020, 25 : 539 - 557
  • [50] Recovery of lignin and lignans enriched fractions from thermomechanical pulp mill process water through membrane separation technology: Pilot-plant study and techno-economic assessment
    Villain-Gambier, M.
    Courbalay, M.
    Klem, A.
    Dumarcay, S.
    Trebouet, D.
    JOURNAL OF CLEANER PRODUCTION, 2020, 249