Two-Dimensional Shear-Wave Elastography on Conventional Ultrasound Scanners With Time-Aligned Sequential Tracking (TAST) and Comb-Push Ultrasound Shear Elastography (CUSE)

被引:86
作者
Song, Pengfei [1 ]
Macdonald, Michael C. [3 ]
Behler, Russell H. [3 ]
Lanning, Justin D. [4 ]
Wang, Michael H. [4 ]
Urban, Matthew W. [1 ]
Manduca, Armando [1 ]
Zhao, Heng [1 ]
Callstrom, Matthew R. [5 ]
Alizad, Azra [1 ,2 ]
Greenleaf, James F. [1 ]
Chen, Shigao [1 ]
机构
[1] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Dept Internal Med, Rochester, MN USA
[3] Gen Elect Healthcare, Ultrasound Gen Imaging Grp, Wauwatosa, WI USA
[4] Gen Elect Healthcare, Wauwatosa, WI USA
[5] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN USA
基金
美国国家卫生研究院;
关键词
RADIATION FORCE; QUANTITATIVE ASSESSMENT; EFSUMB GUIDELINES; HEPATIC-FIBROSIS; CRAWLING WAVES; SOFT-TISSUES; CLINICAL-USE; ELASTICITY; RECOMMENDATIONS; VISCOELASTICITY;
D O I
10.1109/TUFFC.2014.006628
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Two-dimensional shear-wave elastography presents 2-D quantitative shear elasticity maps of tissue, which are clinically useful for both focal lesion detection and diffuse disease diagnosis. Realization of 2-D shear-wave elastography on conventional ultrasound scanners, however, is challenging because of the low tracking pulse-repetition-frequency (PRF) of these systems. Although some clinical and research platforms support software beamforming and plane-wave imaging with high PRF, the majority of current clinical ultrasound systems do not have the software beamforming capability, which presents a critical challenge for translating the 2-D shear-wave elastography technique from laboratory to clinical scanners. To address this challenge, this paper presents a time-aligned sequential tracking (TAST) method for shear-wave tracking on conventional ultrasound scanners. TAST takes advantage of the parallel beamforming capability of conventional systems and realizes high-PRF shear-wave tracking by sequentially firing tracking vectors and aligning shear wave data in the temporal direction. The comb-push ultrasound shear elastography (CUSE) technique was used to simultaneously produce multiple shear wave sources within the field-of-view (FOV) to enhance shear wave SNR and facilitate robust reconstructions of 2-D elasticity maps. TAST and CUSE were realized on a conventional ultrasound scanner. A phantom study showed that the shear-wave speed measurements from the conventional ultrasound scanner were in good agreement with the values measured from other 2-D shear wave imaging technologies. An inclusion phantom study showed that the conventional ultrasound scanner had comparable performance to a state-of-the-art shear-wave imaging system in terms of bias and precision in measuring different sized inclusions. Finally, in vivo case analysis of a breast with a malignant mass, and a liver from a healthy subject demonstrated the feasibility of using the conventional ultrasound scanner for in vivo 2-D shear-wave elastography. These promising results indicate that the proposed technique can enable the implementation of 2-D shear-wave elastography on conventional ultrasound scanners and potentially facilitate wider clinical applications with shear-wave elastography.
引用
收藏
页码:290 / 302
页数:13
相关论文
共 25 条
[1]   Comb-Push Ultrasound Shear Elastography (CUSE) With Various Ultrasound Push Beams [J].
Song, Pengfei ;
Urban, Matthew W. ;
Manduca, Armando ;
Zhao, Heng ;
Greenleaf, James F. ;
Chen, Shigao .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (08) :1435-1447
[2]   Comb-Push Ultrasound Shear Elastography (CUSE): A Novel Method for Two-Dimensional Shear Elasticity Imaging of Soft Tissues [J].
Song, Pengfei ;
Zhao, Heng ;
Manduca, Armando ;
Urban, Matthew W. ;
Greenleaf, James F. ;
Chen, Shigao .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (09) :1821-1832
[3]   Comb-Push Ultrasound Shear Elastography (CUSE) for Evaluation of Thyroid Nodules: Preliminary In Vivo Results [J].
Mehrmohammadi, Mohammad ;
Song, Pengfei ;
Meixner, Duane D. ;
Fazzio, Robert T. ;
Chen, Shigao ;
Greenleaf, James F. ;
Fatemi, Mostafa ;
Alizad, Azra .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (01) :97-106
[4]   Evaluation of Reconstruction Parameters for 2-D Comb-Push Ultrasound Shear Wave Elastography [J].
Racedo, Jorge ;
Urban, Matthew W. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (02) :254-263
[5]   Three-dimensional shear wave elastography on conventional ultrasound scanners with external vibration [J].
Huang, Chengwu ;
Song, Pengfei ;
Mellema, Daniel C. ;
Gong, Ping ;
Lok, U-Wai ;
Tang, Shanshan ;
Ling, Wenwu ;
Meixner, Duane D. ;
Urban, Matthew W. ;
Manduca, Armando ;
Greenleaf, James F. ;
Chen, Shigao .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21)
[6]   Corneal Lamb wave imaging for quantitative assessment of collagen cross-linking treatment based on comb-push ultrasound shear elastography [J].
Zhao, Linfeng ;
Lin, Haoming ;
Hu, Yaxin ;
Chen, Xin ;
Chen, Siping ;
Zhang, Xinyu .
ULTRASONICS, 2021, 116 (116)
[7]   INFLUENCE OF PROBE PRESSURE ON ULTRASOUND-BASED SHEAR WAVE ELASTOGRAPHY OF THE LIVER USING COMB-PUSH 2-D TECHNOLOGY [J].
Byenfeldt, Marie ;
Elvin, Anders ;
Fransson, Per .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (02) :411-428
[8]   Two-Dimensional Shear-Wave Elastography for Kidney Stiffness Assessment [J].
Grosu, Iulia ;
Bob, Flaviu ;
Sporea, Ioan ;
Popescu, Alina ;
Sirli, Roxana ;
Schiller, Adalbert .
ULTRASOUND QUARTERLY, 2021, 37 (02) :144-148
[9]   Reliability and applicability of two-dimensional shear-wave elastography for the evaluation of liver stiffness [J].
Varbobitis, Ioannis C. ;
Siakavellas, Spyros I. ;
Koutsounas, Ioannis S. ;
Karagiannakis, Dimitrios S. ;
Ioannidou, Panagiota ;
Papageorgiou, Maria-Vasiliki ;
Pavlopoulou, Ioanna D. ;
Schizas, Dimitrios ;
Bamias, Giorgos ;
Vlachogiannakos, Ioannis ;
Ladas, Spyros D. ;
Papatheodoridis, George V. .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2016, 28 (10) :1204-1209
[10]   Inter-platform reproducibility of liver stiffness measured with two different point shear wave elastography techniques and 2-dimensional shear wave elastography using the comb-push technique [J].
Ryu, Hwaseong ;
Ahn, Su Joa ;
Yoon, Jeong Hee ;
Lee, Jeong Min .
ULTRASONOGRAPHY, 2019, 38 (04) :345-354