Closed Sinusoid Trajectory for C-Arm CT Imaging

被引:1
|
作者
Yang, Haiquan [1 ]
Li, Meihua [1 ]
Koizumi, Kazuhito [1 ]
Kudo, Hiroyuki [2 ]
机构
[1] Uni Hite Syst Corp, Dept Res & Dev, Kanagawa, Japan
[2] Univ Tsukuba, Grad Sch Syst & Informat Engn, Tsukuba, Ibaraki 305, Japan
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
computed tomography; cone-beam reconstruction; closed sinusoid; C-arm;
D O I
10.1109/NSSMIC.2006.353750
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we investigate cone-beam reconstruction for C-arm CT imaging using a closed sinusoid trajectory, which was firstly studied in [17] and can be considered a generalization of a saddle trajectory [7]. Inspired by the work in [10] and [13], we propose an exact shift-invariant filtered backprojection (FBP) reconstruction algorithm when the scanning trajectory is a closed sinusoid, or a perturbed closed sinusoid. We determine the filtering lines on the detector plane and give the steps to implement the algorithm for the planar detector geometry in a C-arm system. We also give two view independent reconstruction formulae for this geometry, both of which do not involve the view differencing operation and improve the reconstructed images by reducing discretization and sampling errors. The proposed algorithm is tested by simulation studies.
引用
收藏
页码:3480 / 3484
页数:5
相关论文
共 50 条
  • [21] Technical Feasibility of CT Perfusion using a C-Arm CBCT System
    Xu, Min
    Tang, Jie
    Royalty, Kevin
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [22] Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance
    Sheth, Niral M.
    Zbijewski, Wojciech
    Jacobson, Matthew W.
    Abiola, Godwin
    Kleinszig, Gerhard
    Vogt, Sebastian
    Soellradl, Stefan
    Bialkowski, Jens
    Anderson, William S.
    Weiss, Clifford R.
    Osgood, Greg M.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2018, 45 (12) : 5420 - 5436
  • [23] The Added Value of Volume-of-Interest C-Arm CT Imaging during Endovascular Treatment of Intracranial Aneurysms
    Chintalapani, G.
    Chinnadurai, P.
    Maier, A.
    Xia, Y.
    Bauer, S.
    Shaltoni, H.
    Morsi, H.
    Mawad, M. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 660 - 666
  • [24] Low-Dose Volume-of-Interest C-Arm CT Imaging of Intracranial Stents and Flow Diverters
    Yang, P.
    Ahmed, A.
    Schafer, S.
    Niemann, D.
    Aagaard-Kienitz, B.
    Royalty, K.
    Strother, C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 648 - 654
  • [25] Truncation Correction for VOI C-arm CT using Scattered Radiation
    Bier, Bastian
    Maier, Andreas
    Hofmann, Hannes G.
    Schwemmer, Chris
    Xia, Yan
    Struffert, Tobias
    Hornegger, Joachim
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [26] 3D soft tissue imaging with a mobile C-arm
    Ritter, Dieter
    Orman, Jasmina
    Schmidgunst, Christian
    Graumann, Rainer
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (02) : 91 - 102
  • [27] Role of C-Arm Cone-Beam CT in Chemoembolization for Hepatocellular Carcinoma
    Kim, Hyo-Cheol
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (01) : 114 - 124
  • [28] Method for Metal Artifact Avoidance in C-Arm Cone-Beam CT
    Wu, P.
    Sheth, N.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Vijayan, R.
    Vagdargi, P.
    Kreher, B.
    Kunze, H.
    Kleinszig, G.
    Vogt, S.
    Lo, S. -F.
    Theodore, N.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [29] C-Arm CT Measurement of Cerebral Blood Volume: An Experimental Study in Canines
    Ahmed, A. S.
    Zellerhoff, M.
    Strother, C. M.
    Pulfer, K. A.
    Redel, T.
    Deuerling-Zheng, Y.
    Royalty, K.
    Consigny, D.
    Niemann, D. B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (05) : 917 - 922
  • [30] A Novel Temporal Recovery Technique to Enable Cone Beam CT Perfusion Imaging Using an Interventional C-Arm System
    Tang, Jie
    Xu, Min
    Niu, Kai
    Royalty, Kevin
    Pulfer, Kari
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668