An electrochemical and fluorescence dual-signal assay based on Fe3O4@MnO2 and N-doped carbon dots for determination of hydrogen peroxide

被引:24
作者
Zhu, Wanying [1 ,2 ]
Zhou, Ying [3 ]
Tao, Mengdan [1 ,2 ]
Yan, Xiaoqiang [1 ,3 ]
Liu, Yan [1 ,2 ]
Zhou, Xuemin [1 ]
机构
[1] Nanjing Med Univ, Sch Pharm, Nanjing 211166, Peoples R China
[2] Nanjing Med Univ, Collaborat Innovat Ctr Cardiovasc Dis Translat Me, Key Lab Targeted Intervent Cardiovasc Dis, Nanjing 211166, Peoples R China
[3] Nanjing Med Univ, Kangda Coll, Lianyungang 222000, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual-signal; Hydrogen peroxide; Electrochemical method; Fluorescence assay; Fe3O4@MnO2; N-doped carbon dots (NCDs); GRAPHENE QUANTUM DOTS; IMPRINTED POLYMER; H2O2; NANOPARTICLES; FABRICATION; ELECTRODE; MEMBRANE; CELL;
D O I
10.1007/s00604-020-4163-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemical and fluorescence dual-signal assay was developed for the determination of hydrogen peroxide (H2O2) based on Fe3O4@MnO2 and N-doped carbon dots (NCDs). Fe3O4@MnO2 was not only applied as the recognizer for H2O2 but also served as the fluorescence quencher and electrochemical enhancer. This permits the dual-signal readout of the analytical system. In the absence of H2O2, the NCDs were quenched by Fe3O4@MnO2, and the oxidation of the electrochemical probe ferrocene (Fc) was catalyzed by Fe3O4@MnO2. In the presence of H2O2, MnO2 was reduced to Mn-,(2+) leading to the fluorescence recovery of NCDs and the reduction in the oxidation signal of Fc. By combining the electrochemical method and the fluorescence assay, more comprehensive and valuable information for H2O2 determination was provided to meet different analytical demands. The method exhibits good repeatability and selectivity with a detection limit of 1.0 mu M for the fluorescence assay and 0.6 mu M for the electrochemical method. The proposed approach holds great potential for probing released targets from living cells. Graphical abstract
引用
收藏
页数:10
相关论文
共 38 条
[1]   Towards integrated multi-sensor platform using dual electrochemical and optical detection for on-site pollutant detection in water [J].
Belaidi, F. Sekli ;
Farouil, L. ;
Salvagnac, L. ;
Temple-Boyer, P. ;
Seguy, I. ;
Heully, J. L. ;
Alary, F. ;
Bedel-Pereira, E. ;
Launay, J. .
BIOSENSORS & BIOELECTRONICS, 2019, 132 :90-96
[2]   Integration of fluorescence imaging and electrochemical biosensing for both qualitative location and quantitative detection of cancer cells [J].
Cao, Ya ;
Dai, Yuhao ;
Chen, Hong ;
Tang, Yingying ;
Chen, Xu ;
Wang, Ying ;
Zhao, Jing ;
Zhu, Xiaoli .
BIOSENSORS & BIOELECTRONICS, 2019, 130 :132-138
[3]   A dual-mode fluorometric/colorimetric sensor for Cu2+ detection based on hybridized carbon dots and gold-silver core-shell nanoparticles [J].
Chen, Yuqing ;
Lian, Yawen ;
Huang, Mengna ;
Wei, Lin ;
Xiao, Lehui .
ANALYST, 2019, 144 (14) :4250-4257
[4]   Colorimetric and electrochemical (dual) thrombin assay based on the use of a platinum nanoparticle modified metal-organic framework (type Fe-MIL-88) acting as a peroxidase mimic [J].
Cheng, Ting ;
Li, Xiang ;
Huang, Peng ;
Wang, Han ;
Wang, Meixia ;
Yang, Wenming .
MICROCHIMICA ACTA, 2019, 186 (02)
[5]   Ruthenium Ion-Complexed Carbon Nitride Nanosheets with Peroxidase-like Activity as a Ratiometric Fluorescence Probe for the Detection of Hydrogen Peroxide and Glucose [J].
Deng, Wenfang ;
Peng, Yi ;
Yang, Hui ;
Tan, Yueming ;
Ma, Ming ;
Xie, Qjngji ;
Chen, Shaowei .
ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (32) :29072-29077
[6]   The advanced role of carbon quantum dots in nanomedical applications [J].
Devi, Pooja ;
Saini, Shefali ;
Kim, Ki-Hyun .
BIOSENSORS & BIOELECTRONICS, 2019, 141
[7]   A glassy carbon electrode modified with N-doped carbon dots for improved detection of hydrogen peroxide and paracetamol [J].
Fu, Li ;
Wang, Aiwu ;
Lai, Guosong ;
Lin, Cheng-Te ;
Yu, Jinhong ;
Yu, Aimin ;
Liu, Zhong ;
Xie, Kefeng ;
Su, Weitao .
MICROCHIMICA ACTA, 2018, 185 (02)
[8]   MnO2 nanosheets as the biomimetic oxidase for rapid and sensitive oxalate detection combining with bionic E-eye [J].
Gan, Ying ;
Hua, Ning ;
He, Chuanjiang ;
Zhou, Shuqi ;
Tu, Jiawei ;
Liang, Tao ;
Pan, Yuxiang ;
Kirsanov, Dmitry ;
Legin, Andrey ;
Wan, Hao ;
Wang, Ping .
BIOSENSORS & BIOELECTRONICS, 2019, 130 :254-261
[9]   Fabrication of nitrogen-doped carbon dots for screening the purine metabolic disorder in human fluids [J].
Gowthaman, N. S. K. ;
Sinduja, Bharathi ;
Karthikeyan, Rangasamy ;
Rubini, K. ;
John, S. Abraham .
BIOSENSORS & BIOELECTRONICS, 2017, 94 :30-38
[10]   Metal-Organic Framework Loaded by Rhodamine B As a Novel Chemiluminescence System for the Paper-Based Analytical Devices and Its Application for Total Phenolic Content Determination in Food Samples [J].
Hassanzadeh, Javad ;
Al Lawati, Haider A. J. ;
Al Lawati, Iman .
ANALYTICAL CHEMISTRY, 2019, 91 (16) :10631-10639