Notch fatigue of ultrahigh molecular weight polyethylene (UHMWPE) used, in total joint replacements

被引:21
作者
Ansari, Farzana [1 ]
Gludovatz, Bernd [2 ]
Kozak, Adam [3 ]
Ritchie, Robert O. [1 ,2 ,4 ]
Pruitt, Lisa A. [1 ]
机构
[1] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Div Mat Sci, Berkeley, CA 94720 USA
[3] Cambridge Polymer Grp, Boston, MA USA
[4] Univ Calif Berkeley, Dept Mat Sci & Engn, Berkeley, CA 94720 USA
关键词
UHMWPE; Notch fatigue; Fatigue crack propagation; Cross-linking; Vitamin E; CROSS-LINKED UHMWPE; CRACK INITIATION; VITAMIN-E; MECHANICAL-PROPERTIES; STRESS-CONCENTRATIONS; ACETABULAR LINERS; EARLY FAILURE; TIBIAL POST; PROPAGATION; RESISTANCE;
D O I
10.1016/j.jmbbm.2016.02.014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrahigh molecular weight polyethylene (UHMWPE) has remained the primary polymer used in hip, knee and shoulder replacements for over 50 years. Recent case studies have demonstrated that catastrophic fatigue fracture of the polymer can severely limit device lifetime and are often associated with stress concentration (notches) integrated into the design. This study evaluates the influence of notch geometry on the fatigue of three formulations of UHMWPE that are in use today. A linear-elastic fracture mechanics approach is adopted to evaluate crack propagation as a function of notch root radius, heat treatment and Vitamin E additions. Specifically, a modified stress-intensity factor that accounts for notch geometry was utilized to model the crack driving force. The degree of notch plasticity for each material/notch combination was further evaluated using finite element methods. Experimental evaluation of crack speed as a function of stress intensity was conducted under cyclic tensile loading, taking crack length and notch plasticity into consideration. Results demonstrated that crack propagation in UHMWPE emanating from a notch was primarily affected by microstructural influences (cross-linking) rather than differences in notch geometry. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:267 / 279
页数:13
相关论文
共 61 条
[1]   Fractography and oxidative analysis of gamma inert sterilized posterior-stabilized tibial insert post fractures: Report of two cases [J].
Ansari, Farzana ;
Chang, Jennifer ;
Huddleston, James, III ;
Van Citters, Douglas ;
Ries, Michael ;
Pruitt, Lisa .
KNEE, 2013, 20 (06) :609-613
[2]  
ASTM International, 2014, ASTM D638 14 STAND T
[3]  
ASTM International, 2013, ASTM E647 13A STAND
[4]   Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene [J].
Atwood, Sara A. ;
Van Citters, Douglas W. ;
Patten, Eli W. ;
Furmanski, Jevan ;
Ries, Michael D. ;
Pruitt, Lisa A. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (07) :1033-1045
[5]   Compression and tension fatigue resistance of medical grade ultra high molecular weight polyethylene: the effect of morphology, sterilization, aging and temperature [J].
Baker, DA ;
Hastings, RS ;
Pruitt, L .
POLYMER, 2000, 41 (02) :795-808
[6]  
Baker DA, 1999, J BIOMED MATER RES, V46, P573, DOI 10.1002/(SICI)1097-4636(19990915)46:4<573::AID-JBM16>3.3.CO
[7]  
2-1
[8]   The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene [J].
Baker, DA ;
Bellare, A ;
Pruitt, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :146-154
[9]  
Blumenfeld, 2011, J ARTHROPLASTY, V26, pe5
[10]   Fatigue crack propagation resistance of highly crosslinked polyethylene [J].
Bradford, L ;
Baker, D ;
Ries, MD ;
Pruitt, LA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :68-72