摘要
For radiation monitoring at the sires of such nuclear power plant accidents as Fukushima Daiichi, radiation detectors are needed not only for gamma photons but also for alpha and beta particles because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. In some applications, imaging detectors are required to detect the distribution of plutonium particles that emit alpha particles and radiocesium in foods that emits beta particles and gamma photons. To solve these requirements, we developed an imaging detector that can measure the distribution of alpha and beta particles as well as gamma photons. The imaging detector consists of three-layer scintillators optically coupled to each other and to a position sensitive photomultiplier tube (PSPMT). The first layer, which is made of a thin plastic scintillator (decay Lime: similar to 5 ns), detects alpha particles. The second layer, which is made of a thin Gd2SiO5 (GSO) scintillator with 1.5 mol% Ce (decay time 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol% Ce (decay time: 70 no) defects gamma photons. Using pulse shape discrimination, the images of these layers can be separated. The position information is calculated by the Anger principle from 8 x 8 anode signals from the PSPMT. The images for the alpha and beta particles and the gamma photons are individually formed by the pulse shape discriminations for each layer. We detected alpha particle images in the first layer and beta particle images in the second layer. Gamma photon images were detected in the second and third layers. The spatial resolution for the alpha and beta particles was similar to 1.25 mm FWHM and less than 2 mm FWHM for the gamma photons. We conclude that our developed alpha-beta-gamma imaging detector is promising for imaging applications not only for the environmental monitoring of radionuclides but also for medical and molecular imaging. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 23 条
  • [1] Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research
    Bergeron, Melanie
    Cadorette, Jules
    Tetrault, Marc-Andree
    Beaudoin, Jean-Francois
    Leroux, Jean-Daniel
    Fontaine, Rejean
    Lecomte, Roger
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03) : 661 - 678
  • [2] Performance of a YSO/LSO phoswich detector for use in a PET/SPECT system
    Dahlbom, M
    MacDonald, LR
    Eriksson, L
    Paulus, M
    Andreaco, M
    Casey, ME
    Moyers, C
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1114 - 1119
  • [3] A system for simultaneous beta and gamma spectroscopy
    Farsoni, A. T.
    Hamby, D. M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (03) : 528 - 536
  • [4] AN ALPHA-PARTICLE IMAGING-SYSTEM FOR DETECTING PLUTONIUM CONTAMINATION
    IIDA, T
    YAMAMOTO, S
    IKEBE, Y
    SEKI, A
    NAKATA, K
    EBANA, M
    KANAMORI, M
    YOSHIDA, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 212 (1-3): : 413 - 418
  • [5] CERIUM DOPED GSO SCINTILLATORS AND ITS APPLICATION TO POSITION-SENSITIVE DETECTORS
    ISHIBASHI, H
    SHIMIZU, K
    SUSA, K
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 170 - 172
  • [6] Assessment of individual radionuclide distributions from the Fukushima nuclear accident covering central-east Japan
    Kinoshita, Norikazu
    Sueki, Keisuke
    Sasa, Kimikazu
    Kitagawa, Jun-ichi
    Ikarashi, Satoshi
    Nishimura, Tomohiro
    Wong, Ying-Shee
    Satou, Yukihiko
    Handa, Koji
    Takahashi, Tsutomu
    Sato, Masanori
    Yamagata, Takeyasu
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (49) : 19526 - 19529
  • [7] Knoll G., Radiation Detection and Measurement, V4th
  • [8] NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scanner
    Prasad, Rameshwar
    Ratib, Osman
    Zaidi, Habib
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20) : 6649 - 6664
  • [9] Deposition of fission and activation products after the Fukushima Dai-ichi nuclear power plant accident
    Shozugawa, Katsumi
    Nogawa, Norio
    Matsuo, Motoyuki
    [J]. ENVIRONMENTAL POLLUTION, 2012, 163 : 243 - 247
  • [10] A miniature phoswich detector for gamma-ray localization and beta imaging
    Tornai, MP
    Levin, CS
    MacDonald, LR
    Holdsworth, CH
    Hoffman, EJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1166 - 1173