The influence of formulation variables on the performance of alternative propellant-driven metered dose inhalers

被引:109
作者
Smyth, HDC [1 ]
机构
[1] Univ N Carolina, Div Drug Delivery & Disposit, Sch Pharm, Chapel Hill, NC 27599 USA
关键词
asthma; hydrofluoroalkane; aerosol; chlorofluorocarbon; vapor pressure; particle size; lung deposition;
D O I
10.1016/S0169-409X(03)00079-6
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
There are a multitude of formulation factors to consider when developing a pMDI. Evaluation of each of these variables has been performed over the years, but there has been an abundance of different approaches in the determination of the effects on device performance. Thus, although much is known about pMDI on the empirical level, a systematic approach has clearly been missing. With the ratification of the Montreal Protocol and the introduction of alternative propellant systems, the opportunity to establish relationships between different levels of testing, such as in vitro measurements and in vivo outcomes, and in vivo assessments and clinical outcomes, has arrived. This review outlines research efforts that have focused on the formulation of propellant-driven metered dose inhalers using alternative propellants. These formulation factors, including device characteristics, are reviewed with respect to the performance of MDIs. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:807 / 828
页数:22
相关论文
共 152 条
[31]  
BYRON PR, 1987, PHARM TECH, V11, P54
[32]  
BYRON PR, 1987, PHARM TECH, V11, P44
[33]   The effect of spacers on the delivery of metered dose aerosols of nedocromil sodium and disodium cromoglycate [J].
Chew, NYK ;
Chan, HK .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2000, 200 (01) :87-92
[34]   MDIs: Physics of aerosol formation [J].
Clark, AR .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1996, 9 :S19-S26
[35]  
CLARK AR, 1991, METERED ATOMIZATION
[36]   Inhaled corticosteroids for asthma therapy - Patient compliance, devices, and inhalation technique [J].
Cochrane, MG ;
Bala, MV ;
Downs, KE ;
Mauskopf, J ;
Ben-Joseph, RH .
CHEST, 2000, 117 (02) :542-550
[37]   Effect of inhaled fluticasone propionate on airway responsiveness in treatment-naive individuals - a lesser benefit in females [J].
Convery, RP ;
Leitch, DN ;
Bromly, C ;
Ward, RJ ;
Bartlett, G ;
Hendrick, DJ .
EUROPEAN RESPIRATORY JOURNAL, 2000, 15 (01) :19-24
[38]  
Crowder TM., 2001, Pharm Technol, V25, P99
[39]  
Cummings RH, 1998, METERED DOSE INHALER TECHNOLOGY, P147
[40]   COMPARISON OF OUTPUT PARTICLE-SIZE DISTRIBUTIONS FROM PRESSURIZED AEROSOLS FORMULATED AS SOLUTIONS OR SUSPENSIONS [J].
DALBY, RN ;
BYRON, PR .
PHARMACEUTICAL RESEARCH, 1988, 5 (01) :36-39