A Comparative Study of High-Frequency Bioelectrical Impedance Analysis and Dual-Energy X-ray Absorptiometry for Estimating Body Composition

被引:21
|
作者
Yi, Youngseok [1 ]
Baek, Ji Yeon [1 ]
Lee, Eunju [1 ]
Jung, Hee-Won [1 ]
Jang, Il-Young [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Internal Med, Div Geriatr,Coll Med, Seoul 05505, South Korea
来源
LIFE-BASEL | 2022年 / 12卷 / 07期
关键词
bioelectrical impedance analysis (BIA); dual-energy X-ray absorptiometry (DEXA); high-frequency bioelectrical impedance analysis (HF-BIA); body composition; sarcopenia; muscle mass; SKELETAL-MUSCLE MASS; FAT MASS; BIOIMPEDANCE ANALYSIS; WHOLE-BODY; ACCURACY; DIAGNOSIS; VALIDITY; OBESITY;
D O I
10.3390/life12070994
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Though bioelectrical impedance analysis (BIA) is a favorable tool for assessing body composition to estimate nutritional status and physical fitness, such as sarcopenia, there are accuracy issues. Hence, high-frequency (HF) BIA equipment uses an additional frequency of 2 and 3 MHz and has been developed as a commercial model. However, there are no studies validating the accuracy and safety of HF-BIA. Therefore, this study aims to assess the validity of HF-BIA in analyzing body composition relative to dual-energy X-ray absorptiometry (DEXA). Appendicular lean mass (ALM), fat-free mass (FFM), and percentage of body fat (PBF) were assessed by HF-BIA and DEXA in 109 individuals; 50.5% (n = 55) were males. The average age and body mass index (BMI) were 43.4 +/- 14.7 years and 25.5 +/- 6.7 in males and 44.9 +/- 14.1 years and 24.0 +/- 6.4 in females, respectively. The HF-BIA results showed a high correlation with the DEXA results for assessing ALM (standard coefficient beta (beta) >= 0.95), FFM (beta >= 0.98, coefficient of determinations (R-2) >= 0.95), and PBF (beta >= 0.94, R-2 >= 0.89). Body composition measured by HF-BIA demonstrated good agreement with DEXA in Korean adults.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Increased adiposity in juvenile idiopathic arthritis - A comparison of the bioelectrical impedance analysis and dual-energy X-ray absorptiometry for the assessment of body composition
    Rasanen, Kati
    Soisalo, Katja
    Markula-Patjas, Kati
    Kantanen, Saija
    Sipila, Kalle
    Lakka, Timo A.
    Valve-Dietz, Anna-Kaisa
    Piippo-Savolainen, Eija
    Arikoski, Pekka
    ACTA PAEDIATRICA, 2024, 113 (09) : 2072 - 2080
  • [42] Body weight difference between dual-energy X-ray absorptiometry and multi-frequency bioelectrical impedance analysis attenuates the equivalence of body-composition assessment
    Pham, Duong Duc
    Lee, Seung Ku
    Shin, Chol
    Kim, Nan Hee
    Leem, Chae Hun
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2019, 73 (03) : 387 - 394
  • [43] Appendicular Body Composition Analysis: Validity of Bioelectrical Impedance Analysis Compared With Dual-Energy X-Ray Absorptiometry in Division I College Athletes
    Brewer, Gabrielle J.
    Blue, Malia N. M.
    Hirsch, Katie R.
    Peterjohn, Austin M.
    Smith-Ryan, Abbie E.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (11) : 2920 - 2925
  • [44] Dual-energy X-ray absorptiometry analysis of body composition in patients affected by OSAS
    Ernesto Bruno
    Marco Alessandrini
    Bianca Napolitano
    Alessandro De Padova
    Nicola Di Daniele
    Antonino De Lorenzo
    European Archives of Oto-Rhino-Laryngology, 2009, 266 : 1285 - 1290
  • [45] Body Composition Comparison: Bioelectric Impedance Analysis with Dual-Energy X-Ray Absorptiometry in Adult Athletes
    Company, Joe
    Ball, Stephen
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2010, 14 (03) : 186 - 201
  • [46] Bioelectrical impedance analysis as an alternative to dual-energy x-ray absorptiometry in the assessment of fat mass and appendicular lean mass in patients with obesity
    Ballesteros-Pomar, Maria D.
    Gonzalez-Arnaiz, Elena
    Pintor-de-la Maza, Begona
    Barajas-Galindo, David
    Ariadel-Cobo, Diana
    Gonzalez-Roza, Lucia
    Cano-Rodriguez, Isidoro
    NUTRITION, 2022, 93
  • [47] Dual-energy X-ray absorptiometry analysis of body composition in patients affected by OSAS
    Bruno, Ernesto
    Alessandrini, Marco
    Napolitano, Bianca
    De Padova, Alessandro
    Di Daniele, Nicola
    De Lorenzo, Antonino
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2009, 266 (08) : 1285 - 1290
  • [48] Body Composition, Serum Sclerostin and Physical Function After Bariatric Surgery: Performance of Dual-Energy X-ray Absorptiometry and Multifrequency Bioelectrical Impedance Analysis
    Prazeres de Oliveira, Paula Aragao
    Peres Montenegro, Ana Carla
    Alves Bezerra, Louise Rayra
    Chaves de Lemos, Maria da Conceicao
    Bandeira, Francisco
    OBESITY SURGERY, 2020, 30 (08) : 2957 - 2962
  • [49] Body Composition, Serum Sclerostin and Physical Function After Bariatric Surgery: Performance of Dual-Energy X-ray Absorptiometry and Multifrequency Bioelectrical Impedance Analysis
    Paula Aragão Prazeres de Oliveira
    Ana Carla Peres Montenegro
    Louise Rayra Alves Bezerra
    Maria da Conceição Chaves de Lemos
    Francisco Bandeira
    Obesity Surgery, 2020, 30 : 2957 - 2962
  • [50] Evaluation of Multi-Frequency Bioelectrical Impedance Analysis against Dual-Energy X-ray Absorptiometry for Estimation of Low Muscle Mass in Older Hospitalized Patients
    Nielsen, Rikke Lundsgaard
    Andersen, Aino Leegaard
    Kallemose, Thomas
    Damgaard, Morten
    Bornaes, Olivia
    Juul-Larsen, Helle Gybel
    Strejby Christensen, Louise Westberg
    Jawad, Baker Nawfal
    Andersen, Ove
    Rasmussen, Henrik Hojgaard
    Munk, Tina
    Lund, Trine Meldgaard
    Houlind, Morten Baltzer
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (01)