Advances in functionalized polymer coatings on biodegradable magnesium alloys - A review

被引:355
作者
Li, Ling-Yu [1 ]
Cui, Lan-Yue [1 ]
Zeng, Rong-Chang [1 ]
Li, Shuo-Qi [1 ]
Chen, Xiao-Bo [2 ]
Zheng, Yufeng [3 ]
Kannan, M. Bobby [4 ]
机构
[1] Shandong Univ Sci & Technol, Coll Mat Sci & Engn, Qingdao 266590, Peoples R China
[2] RMIT Univ, Sch Engn, Carlton, Vic 3053, Australia
[3] Peking Univ, Dept Mat Sci & Engn, Coll Engn, Beijing 100871, Peoples R China
[4] James Cook Univ, Coll Sci & Engn, Biomat & Engn Mat BEM Lab, Townsville, Qld 4811, Australia
基金
中国国家自然科学基金;
关键词
Magnesium alloy; Biomaterial; Polymer coating; Degradation; Functional properties; IN-VITRO CORROSION; MG-CA ALLOYS; FLUORINE-DOPED HYDROXYAPATITE; EPSILON-CAPROLACTONE PCL; COLLAGEN TYPE-I; BIOMEDICAL APPLICATIONS; ANTIBACTERIAL PERFORMANCE; ORTHOPEDIC APPLICATIONS; COMPOSITE COATINGS; AZ31; ALLOY;
D O I
10.1016/j.actbio.2018.08.030
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnesium (Mg) and its alloys have become a research frontier in biodegradable materials owing to their superior biocompatibility and excellent biomechanical compatibility. However, their high degradation rate in the physiological environment should be well tackled prior to clinical applications. This review summarizes the latest progress in the development of polymeric coatings on biodegradable Mg alloys over the last decade, regarding preparation strategies for polylactic acid (PLA), poly (latic-co-glycolic) acid (PLGA), polycaprolactone (PCL), polydopamine (PDA), chitosan (CS), collagen (Col) and their composite, and their performance in terms of corrosion resistance and biocompatibility. Feasible perspectives and developing directions of next generation of polymeric coatings with respect to biomedical Mg alloys are briefly discussed. Statement of Significance Magnesium (Mg) and its alloys have become a research frontier in biodegradable materials owing to their superior biocompatibility and suitable biomechanical compatibility. However, the principal drawback of Mg-based implants is their poor corrosion resistance in physiological environments. Hence, it is vital to mitigate the degradation/corrosion behavior of Mg alloys for safe biomedical deployments. This review summarizes the latest progress in development of polymeric coatings on biomedical Mg alloys regarding preparation strategy, corrosion resistance and biocompatibility, including polylactic acid (PLA), poly (latic-co-glycolic) acid (PLGA), polycaprolactone (PCL), chitosan (CS), polydopamine (PDA), collagen (Col) and their composite. In addition, functionalized polymer coatings with Mg alloys exhibits a promising prospect owing to their ability of degradation along with biocompatibility, self-healing, drug-delivery and osteoinduction. (C) 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:23 / 36
页数:14
相关论文
共 135 条
  • [1] Enhanced biocorrosion resistance of surface modified magnesium alloys using inorganic/organic composite layer for biomedical applications
    Abdal-hay, Abdalla
    Dewidar, Montasser
    Lim, Juhyun
    Lim, Jae Kyoo
    [J]. CERAMICS INTERNATIONAL, 2014, 40 (01) : 2237 - 2247
  • [2] Biocorrosion and osteoconductivity of PCL/nHAp composite porous film-based coating of magnesium alloy
    Abdal-hay, Abdalla
    Amna, Touseef
    Lim, Jae Kyoo
    [J]. SOLID STATE SCIENCES, 2013, 18 : 131 - 140
  • [3] Magnesium incorporated chitosan based scaffolds for tissue engineering applications
    Adhikari, Udhab
    Rijal, Nava P.
    Khanal, Shalil
    Pai, Devdas
    Sankar, Jagannathan
    Bhattarai, Narayan
    [J]. BIOACTIVE MATERIALS, 2016, 1 (02) : 132 - 139
  • [4] Biodegradable magnesium alloys for orthopaedic applications: A review on corrosion, biocompatibility and surface modifications
    Agarwal, Sankalp
    Curtin, James
    Duffy, Brendan
    Jaiswal, Swarna
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 68 : 948 - 963
  • [5] Polylactic acid coating on a biodegradable magnesium alloy: An in vitro degradation study by electrochemical impedance spectroscopy
    Alabbasi, Alyaa
    Liyanaarachchi, S.
    Kannan, M. Bobby
    [J]. THIN SOLID FILMS, 2012, 520 (23) : 6841 - 6844
  • [6] Biodegradable Bi-layered coating on polymeric orthopaedic implants for controlled release of drugs
    Argarate, Nerea
    Olalde, Beatriz
    Atorrasagasti, Garbine
    Valero, Jesus
    Carolina Cifuentes, Sandra
    Benavente, Rosario
    Lieblich, Marcela
    Luis Gonzalez-Carrasco, Jose
    [J]. MATERIALS LETTERS, 2014, 132 : 193 - 195
  • [7] Advances in Mg corrosion and research suggestions
    Atrens, Andrej
    Song, Guang-Ling
    Cao, Fuyong
    Shi, Zhiming
    Bowen, Patrick K.
    [J]. JOURNAL OF MAGNESIUM AND ALLOYS, 2013, 1 (03) : 177 - 200
  • [8] Fabrication of chitosan/magnesium phosphate composite coating and the in vitro degradation properties of coated magnesium alloy
    Bai, Kuifeng
    Zhang, Yi
    Fu, Zhenya
    Zhang, Caili
    Cui, Xinzhan
    Meng, Erchao
    Guan, Shaokang
    Hu, Junhua
    [J]. MATERIALS LETTERS, 2012, 73 : 59 - 61
  • [9] Fabrication and characterization of hydrophobic microarc oxidation/poly-lactic acid duplex coating on biodegradable Mg-Ca alloy for corrosion protection
    Bakhsheshi-Rad, H. R.
    Hamzah, E.
    Ebrahimi-Kahrizsangi, R.
    Daroonparvar, M.
    Medraj, M.
    [J]. VACUUM, 2016, 125 : 185 - 188
  • [10] Deposition of nanostructured fluorine-doped hydroxyapatite-polycaprolactone duplex coating to enhance the mechanical properties and corrosion resistance of Mg alloy for biomedical applications
    Bakhsheshi-Rad, H. R.
    Hamzah, E.
    Kasiri-Asgarani, M.
    Jabbarzare, S.
    Iqbal, N.
    Kadir, M. R. Abdul
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 60 : 526 - 537