Measurement prototype for fast estimation of building wall thermal resistance under controlled and natural environmental conditions

被引:7
作者
Ha, Thanh-Tung [1 ]
Feuillet, Vincent [1 ]
Waeytens, Julien [2 ]
Zibouche, Kamel [3 ]
Peiffer, Laurent [4 ]
Garcia, Yann [5 ]
Sant, Veronique Le [5 ]
Bouchie, Remi [3 ]
Koenen, Alain [5 ]
Monchau, Jean-Pierre [6 ]
Ibos, Laurent [1 ]
机构
[1] Univ Paris Est Creteil, CERTES, F-94010 Creteil, France
[2] Univ Gustave Eiffel, IFSTTAR, Cite Descartes,14-20 Blvd Newton, F-77420 Champs Sur Marne, Marne, France
[3] Ctr Sci & Tech Batiment CSTB, 84 Ave Jean Jaures, F-77420 Champs Sur Marne, Marne, France
[4] Cerema, 71 Rue Grande Haie, F-54510 Tomblaine, France
[5] Lab Natl Metrol & Essais LNE, 29 Rue Roger Hennequin, F-78197 Trappes, France
[6] THEMACS Ingn, 2bis Rue Alfred Nobel, F-77420 Champs Sur Marne, Marne, France
关键词
Building walls; Thermal resistance; In situ measurement; Active method; Inverse problem; IN-SITU; U-VALUE; THERMOPHYSICAL PROPERTIES; INFRARED THERMOGRAPHY; PERFORMANCE; TEMPERATURE; UNCERTAINTY; CALIBRATION; DIAGNOSIS;
D O I
10.1016/j.enbuild.2022.112166
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Most of the methods for in situ measurement of the thermal resistance of building walls implement passive approaches requiring long measurement times and specific environmental conditions. In the literature, different active approaches have been studied but they remain limited in terms of applications and do not systematically lead to short identification times. This article that follows a previous numerical benchmark study presents a new measurement prototype using a lamp box which heats up one of the surfaces (typically the interior surface) of the wall to be characterized. The use of an aluminum plate placed in contact with the wall face subjected to thermal excitation enables the homogenization of the heat flux transmitted to the wall. Three inverse procedures are implemented to estimate the thermal resistance of the studied wall. The originality of this work comes from an exhaustive measurement campaign. On the one hand, four types of wall among the most common in France, i.e. Internal Insulation Wall, External Insulation Wall and Wood Frame Wall specially built for this study and a Single Concrete Wall located in a real building, were investigated. On the other hand, the use of different climatic chambers made it possible to generate many different environmental conditions (constant, variable and natural). The results highlight the possibilities offered by this in situ experimental device for estimating in a few hours (6 to 10 h) the thermal resistance of the wall studied or of its first layers, as well as the limits depending on the type of wall and the environmental conditions. Some operational recommendations are also provided: avoiding thermal bridges, solar protection in case of strong sunlight on the exterior side of the wall and location of the device on the exterior side in the case of the External Insulation Wall. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:20
相关论文
共 53 条
[1]   A comprehensive experimental approach for the validation of quantitative infrared thermography in the evaluation of building thermal transmittance [J].
Albatici, Rossano ;
Tonelli, Arnaldo M. ;
Chiogna, Michela .
APPLIED ENERGY, 2015, 141 :218-228
[2]   A perturbation method to estimate building thermal performance [J].
Alzetto, Florent ;
Meulemans, Johann ;
Pandraud, Guillaume ;
Roux, Didier .
COMPTES RENDUS CHIMIE, 2018, 21 (10) :938-942
[3]  
[Anonymous], CTSM R CONTINUOUS TI
[4]  
[Anonymous], 2014, 98691201 ISO
[5]  
[Anonymous], 2018, ISO 9869-2
[6]  
[Anonymous], 2012, Reglementation Thermique RT 2012
[7]  
[Anonymous], 1994, Thermal InsulationDetermination of Steady-State Thermal Transmission PropertiesCalibrated and Guarded Hot Box
[8]  
[Anonymous], 2017, ISO 6946:2017-Building components and building elements-Thermal resistance and thermal transmittance
[9]   Identifying suitable models for the heat dynamics of buildings [J].
Bacher, Peder ;
Madsen, Henrik .
ENERGY AND BUILDINGS, 2011, 43 (07) :1511-1522
[10]   Performance evaluation of material and comparison of different temperature control strategies of a Guarded Hot Box U-value Test Facility [J].
Basak, Chayan Kumar ;
Sarkar, Gautam ;
Neogi, Subhasis .
ENERGY AND BUILDINGS, 2015, 105 :258-262