Assessment of the Operative Feasibility and Ventilation Distribution during Nonintubation Thoracoscopic Surgery Using Electrical Impedance Tomography

被引:1
|
作者
Lin, Kuan-Hsun [1 ]
Chu, Pei-Yi [1 ]
Zhao, Zhanqi [2 ]
Chang, Hung [1 ]
Yun, Po-Jen [1 ]
Huang, Tsai-Wang [1 ]
机构
[1] Triserv Gen Hosp, Natl Def Med Ctr, Dept Surg, Div Thorac Surg, Taipei 11490, Taiwan
[2] Furtwangen Univ, Inst Tech Med, D-78054 Villingen Schwenningen, Germany
来源
JOURNAL OF PERSONALIZED MEDICINE | 2022年 / 12卷 / 07期
关键词
nonintubated thoracic surgery; ventilation; electrical impedance tomography; LUNG; LOBECTOMY; TUBE;
D O I
10.3390/jpm12071066
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: To investigate the feasibility, ventilation distribution, and physiological effect of iatrogenic pneumothorax generated during nonintubated thoracoscopic surgery using electrical impedance tomography. Methods: Patients who underwent resections for pulmonary nodules between April 2016 and April 2019 were enrolled prospectively. Electrical impedance tomography was performed, and the measurements were recorded at five different timepoints. The patient characteristics, pathological characteristics, surgical procedures, operation times, and intraoperative parameters were recorded and analyzed. Results: Two hundred sixty-five perioperative electrical impedance tomography measurements during nonintubated thoracoscopic surgery were recorded in fifty-three patients. Fifty-one patients underwent wedge resections, and two patients underwent segmentectomies. The preoperative lateral decubitus position time point showed greater ventilation in the right lung than in the left lung. For left-sided surgery, the nonoperative lung had better ventilation (64.5% +/- 14.1% for the right side vs. 35.5% +/- 14.1% for the left side, p < 0.0001). For right-sided surgery, the nonoperative lung did not have better ventilation (52.4% +/- 16.1% for the right side vs. 47.6% +/- 16.1% for the left side, p = 0.44). The center of ventilation was significantly increased after surgery (p < 0.001). The global index of ventilation showed no difference after surgery. Conclusions: The nonintubated thoracoscopic surgical side had different ventilation distributions but reached ventilation equilibrium after the operation. Electrical impedance tomography is feasible and safe for monitoring ventilation without adverse effects.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The regional ventilation distribution monitored by electrical impedance tomography during anesthesia induction with head-rotated mask ventilation
    Xu, Qing
    Fang, Yijiao
    Pan, Congxia
    Gao, Lingling
    Zhu, Yun
    Zhang, Jun
    Zhao, Zhanqi
    Yang, Li
    PHYSIOLOGICAL MEASUREMENT, 2025, 13 (01)
  • [22] Monitoring of regional lung ventilation using electrical impedance tomography
    Vasques, Francesco
    Sanderson, Barnaby
    Barrett, Nicholas A.
    Camporota, Luigi
    MINERVA ANESTESIOLOGICA, 2019, 85 (11) : 1231 - 1241
  • [23] Feasibility of Electric Impedance Tomography in the Assessment of Lung Perfusion and Ventilation in Congenital Pulmonary Vein Stenosis
    Zablah, Jenny E.
    Vargas-Acevedo, Catalina
    da BarbosaRosa Jr, Nilton
    Shishvan, Omid Rajabi
    Saulnier, Gary
    Isaacson, David
    Morgan, Gareth J.
    Mueller, Jennifer L.
    PEDIATRIC CARDIOLOGY, 2025,
  • [24] Redistribution of pulmonary ventilation after lung surgery detected with electrical impedance tomography
    Lehmann, Martin
    Oehler, Beatrice
    Zuber, Jonas
    Malzahn, Uwe
    Walles, Thorsten
    Muellenbach, Ralf M.
    Roewer, Norbert
    Kredel, Markus
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2020, 64 (04) : 517 - 525
  • [25] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Krause, Ulrich
    Becker, Kristin
    Hahn, Guenter
    Dittmar, Joerg
    Ruschewski, Wolfgang
    Paul, Thomas
    PEDIATRIC CARDIOLOGY, 2014, 35 (06) : 990 - 997
  • [26] Feasibility of neonatal lung imaging using electrical impedance tomography
    Taktak, A
    Spencer, A
    Record, P
    Gadd, R
    Rolfe, P
    EARLY HUMAN DEVELOPMENT, 1996, 44 (02) : 131 - 138
  • [27] Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography
    Frerichs, I
    Hahn, G
    Golisch, W
    Kurpitz, M
    Burchardi, H
    Hellige, G
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (06) : 721 - 726
  • [28] Assessment of the Spatial Distribution of Moisture Content in Granular Material Using Electrical Impedance Tomography
    Porzuczek, Jan
    SENSORS, 2019, 19 (12)
  • [29] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Ulrich Krause
    Kristin Becker
    Günter Hahn
    Jörg Dittmar
    Wolfgang Ruschewski
    Thomas Paul
    Pediatric Cardiology, 2014, 35 : 990 - 997
  • [30] Noninvasive ventilation during spontaneous breathing anesthesia: an observational study using electrical impedance tomography
    Bordes, Julien
    Goutorbe, Philippe
    Cungi, Pierre Julien
    Boghossian, Marie Caroline
    Kaiser, Eric
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 420 - 426